Milovanović, Aleksa

Link to this page

Authority KeyName Variants
9ed51c50-ecd2-4893-bc09-4cbfc6dbfb0b
  • Milovanović, Aleksa (4)
Projects

Author's Bibliography

Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads

Smoljanić, Tamara; Milovanović, Aleksa; Sedmak, Simon; Milović, Ljubica; Sedmak, Aleksandar

(Savez hemijskih inženjera Srbije, 2023)

TY  - JOUR
AU  - Smoljanić, Tamara
AU  - Milovanović, Aleksa
AU  - Sedmak, Simon
AU  - Milović, Ljubica
AU  - Sedmak, Aleksandar
PY  - 2023
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7039
AB  - This paper presents development of numerical models for simulation of the behaviour of titanium alloy hip implants under static and dynamic loads, which is a part of extensive research involving the structural integrity of such implants under various loading conditions, as well as under exposure to aggressive environments. Numerical models were created in ABAQUS and ANSYS software packages, in order to determine the stress/strain distribution, the number of cycles to failure and stress intensity factors, for two different hip implant geometries. The ABAQUS models were used for static and ANSYS models for dynamic loads. The next stage in this analysis involved comparing these two cases, to determine the one with the better behaviour, depending on the exploitation conditions, which can greatly vary between different groups of patients. The targeted patient weight for all numerical simulations was 90 kg, while failure assessment diagrams were made for both implant geometries, assuming a crack length of 1 mm.
AB  - U ovom radu je prikazan razvoj numeričkih modela za simulaciju implantata za zamenu zgloba kuka pod
statičkim i dinamičkim opterećenjima, kao deo širokog istraživanja koje uključuje procenu integriteta
implantata kuka u različitim uslovima, kao što su zamor i korozija. Numerički modeli su napravljeni u
ABAQUS i ANSYS softverskim paketima, u cilju procene distribucije napon/deformacija i broja ciklusa do
loma, kao i vrednosti faktora intenziteta napona za dve različite geometrije implanta kuka. ABAQUS
modeli su korišćeni za simulaciju pod statičkim, a ANSYS modeli za simulaciju pod dinamičkim
opterećenjima. Sledeća etapa analize uključuje poređenje ova dva slučaja, kako bi se odredilo koja od
ove dve geometrije pruža bolje ponašanje u eksploatacionim uslovima, a koje mogu značajno varirati
zavisno od pacijenta. Simulacije su vršene za pacijenta mase 90 kg. Za ovu svrhu, dijagrami procene rizika
su napravljeni za obe navedene geometrije, pod pretpostavkom da je dužina inicijalne prsline 1 mm.
PB  - Savez hemijskih inženjera Srbije
T2  - Hemijska industrija
T1  - Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads
T1  - Numerička simulacija implantata kuka od legure titanijuma pod
statičkim i dinamičkim opterećenjima
EP  - 292
IS  - 4
SP  - 283
VL  - 77
DO  - 10.2298/HEMIND221118026S
ER  - 
@article{
author = "Smoljanić, Tamara and Milovanović, Aleksa and Sedmak, Simon and Milović, Ljubica and Sedmak, Aleksandar",
year = "2023",
abstract = "This paper presents development of numerical models for simulation of the behaviour of titanium alloy hip implants under static and dynamic loads, which is a part of extensive research involving the structural integrity of such implants under various loading conditions, as well as under exposure to aggressive environments. Numerical models were created in ABAQUS and ANSYS software packages, in order to determine the stress/strain distribution, the number of cycles to failure and stress intensity factors, for two different hip implant geometries. The ABAQUS models were used for static and ANSYS models for dynamic loads. The next stage in this analysis involved comparing these two cases, to determine the one with the better behaviour, depending on the exploitation conditions, which can greatly vary between different groups of patients. The targeted patient weight for all numerical simulations was 90 kg, while failure assessment diagrams were made for both implant geometries, assuming a crack length of 1 mm., U ovom radu je prikazan razvoj numeričkih modela za simulaciju implantata za zamenu zgloba kuka pod
statičkim i dinamičkim opterećenjima, kao deo širokog istraživanja koje uključuje procenu integriteta
implantata kuka u različitim uslovima, kao što su zamor i korozija. Numerički modeli su napravljeni u
ABAQUS i ANSYS softverskim paketima, u cilju procene distribucije napon/deformacija i broja ciklusa do
loma, kao i vrednosti faktora intenziteta napona za dve različite geometrije implanta kuka. ABAQUS
modeli su korišćeni za simulaciju pod statičkim, a ANSYS modeli za simulaciju pod dinamičkim
opterećenjima. Sledeća etapa analize uključuje poređenje ova dva slučaja, kako bi se odredilo koja od
ove dve geometrije pruža bolje ponašanje u eksploatacionim uslovima, a koje mogu značajno varirati
zavisno od pacijenta. Simulacije su vršene za pacijenta mase 90 kg. Za ovu svrhu, dijagrami procene rizika
su napravljeni za obe navedene geometrije, pod pretpostavkom da je dužina inicijalne prsline 1 mm.",
publisher = "Savez hemijskih inženjera Srbije",
journal = "Hemijska industrija",
title = "Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads, Numerička simulacija implantata kuka od legure titanijuma pod
statičkim i dinamičkim opterećenjima",
pages = "292-283",
number = "4",
volume = "77",
doi = "10.2298/HEMIND221118026S"
}
Smoljanić, T., Milovanović, A., Sedmak, S., Milović, L.,& Sedmak, A.. (2023). Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads. in Hemijska industrija
Savez hemijskih inženjera Srbije., 77(4), 283-292.
https://doi.org/10.2298/HEMIND221118026S
Smoljanić T, Milovanović A, Sedmak S, Milović L, Sedmak A. Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads. in Hemijska industrija. 2023;77(4):283-292.
doi:10.2298/HEMIND221118026S .
Smoljanić, Tamara, Milovanović, Aleksa, Sedmak, Simon, Milović, Ljubica, Sedmak, Aleksandar, "Numerical simulation of titanium alloy hip replacement implants behaviour under static and dynamic loads" in Hemijska industrija, 77, no. 4 (2023):283-292,
https://doi.org/10.2298/HEMIND221118026S . .

Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions

Smoljanić, Tamara; Sedmak, Simon; Milovanović, Aleksa; Milović, Ljubica

(Elsevier B.V., 2023)

TY  - CONF
AU  - Smoljanić, Tamara
AU  - Sedmak, Simon
AU  - Milovanović, Aleksa
AU  - Milović, Ljubica
PY  - 2023
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/6628
AB  - One of the most important aspects of materials typically used in biomedical engineering is their resistance to various unfavourable exploitation conditions, which greatly impact their work life. In terms of extreme conditions, two major factors include fatigue and corrosion, and a combination of these can significantly decrease the expected life of various implants. The focus of this paper will be on hip implants made of Ti-Al6-4V titanium alloy, a material commonly used in such applications, due to its resistance to corrosion and bio-compatibility. Research shown here was based on experimental testing of said alloy in order to determine its mechanical properties under different working environments, including normal, salty and wet conditions. These properties were then used as input data for Extended Finite Element method (XFEM) numerical simulations of fatigue crack growth in hip implants with various geometries. This was of particular interest since specimens which were kept in salty and wet environment had a slight degradation of yield stress and tensile strength, but an increase in plasticity.
PB  - Elsevier B.V.
C3  - Procedia Structural Integrity
T1  - Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions
EP  - 221
SP  - 215
VL  - 48
DO  - 10.1016/j.prostr.2023.07.151
UR  - https://hdl.handle.net/21.15107/rcub_technorep_6628
ER  - 
@conference{
author = "Smoljanić, Tamara and Sedmak, Simon and Milovanović, Aleksa and Milović, Ljubica",
year = "2023",
abstract = "One of the most important aspects of materials typically used in biomedical engineering is their resistance to various unfavourable exploitation conditions, which greatly impact their work life. In terms of extreme conditions, two major factors include fatigue and corrosion, and a combination of these can significantly decrease the expected life of various implants. The focus of this paper will be on hip implants made of Ti-Al6-4V titanium alloy, a material commonly used in such applications, due to its resistance to corrosion and bio-compatibility. Research shown here was based on experimental testing of said alloy in order to determine its mechanical properties under different working environments, including normal, salty and wet conditions. These properties were then used as input data for Extended Finite Element method (XFEM) numerical simulations of fatigue crack growth in hip implants with various geometries. This was of particular interest since specimens which were kept in salty and wet environment had a slight degradation of yield stress and tensile strength, but an increase in plasticity.",
publisher = "Elsevier B.V.",
journal = "Procedia Structural Integrity",
title = "Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions",
pages = "221-215",
volume = "48",
doi = "10.1016/j.prostr.2023.07.151",
url = "https://hdl.handle.net/21.15107/rcub_technorep_6628"
}
Smoljanić, T., Sedmak, S., Milovanović, A.,& Milović, L.. (2023). Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions. in Procedia Structural Integrity
Elsevier B.V.., 48, 215-221.
https://doi.org/10.1016/j.prostr.2023.07.151
https://hdl.handle.net/21.15107/rcub_technorep_6628
Smoljanić T, Sedmak S, Milovanović A, Milović L. Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions. in Procedia Structural Integrity. 2023;48:215-221.
doi:10.1016/j.prostr.2023.07.151
https://hdl.handle.net/21.15107/rcub_technorep_6628 .
Smoljanić, Tamara, Sedmak, Simon, Milovanović, Aleksa, Milović, Ljubica, "Numerical simulation of fatigue crack growth in Ti-Al6-V4 hip implants under different exploitation conditions" in Procedia Structural Integrity, 48 (2023):215-221,
https://doi.org/10.1016/j.prostr.2023.07.151 .,
https://hdl.handle.net/21.15107/rcub_technorep_6628 .

Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant

Mijatović, Tamara; Milovanović, Aleksa; Sedmak, Aleksandar; Milović, Ljubica; Čolić, Katarina

(Society for Structural Integrity and Life, Institute for Material Testing, 2019)

TY  - JOUR
AU  - Mijatović, Tamara
AU  - Milovanović, Aleksa
AU  - Sedmak, Aleksandar
AU  - Milović, Ljubica
AU  - Čolić, Katarina
PY  - 2019
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4195
AB  - Total hip replacement implants are used as an artificial replacement for disfunctional hips in order to sustain joint movement. Chosen material and design of total hip replacement are the most influential factors for artificial joint utilization. Selected total hip replacement is obtained by precision casting method, made from Ti6Al4V ELI (Extra Low Interstitials) alloy. In order to acquire a geometrical model of chosen implant, the 3D scanner is used and an obtained point cloud (PC), then exploited for reverse engineering to a CAD model. The neck thickness of implant affects angle of movement of the joint and structural integrity. Reducing the thickness of the neck section results in higher movement of the joint, but inversely affects its structural integrity. The 3D scanned implant has a neck thickness of 14.6 mm, and data from literature suggest that the best movement angle is for 9 mm thickness of the implant. In order to redesign the available implant, five different models with a neck thickness between 9 and 14.6 mm are made. Obtained results show the thickness effects the stress distribution in a critical area.
PB  - Society for Structural Integrity and Life, Institute for Material Testing
T2  - Structural Integrity and Life
T1  - Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant
EP  - 242
IS  - 3
SP  - 237
VL  - 19
UR  - https://hdl.handle.net/21.15107/rcub_technorep_4195
ER  - 
@article{
author = "Mijatović, Tamara and Milovanović, Aleksa and Sedmak, Aleksandar and Milović, Ljubica and Čolić, Katarina",
year = "2019",
abstract = "Total hip replacement implants are used as an artificial replacement for disfunctional hips in order to sustain joint movement. Chosen material and design of total hip replacement are the most influential factors for artificial joint utilization. Selected total hip replacement is obtained by precision casting method, made from Ti6Al4V ELI (Extra Low Interstitials) alloy. In order to acquire a geometrical model of chosen implant, the 3D scanner is used and an obtained point cloud (PC), then exploited for reverse engineering to a CAD model. The neck thickness of implant affects angle of movement of the joint and structural integrity. Reducing the thickness of the neck section results in higher movement of the joint, but inversely affects its structural integrity. The 3D scanned implant has a neck thickness of 14.6 mm, and data from literature suggest that the best movement angle is for 9 mm thickness of the implant. In order to redesign the available implant, five different models with a neck thickness between 9 and 14.6 mm are made. Obtained results show the thickness effects the stress distribution in a critical area.",
publisher = "Society for Structural Integrity and Life, Institute for Material Testing",
journal = "Structural Integrity and Life",
title = "Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant",
pages = "242-237",
number = "3",
volume = "19",
url = "https://hdl.handle.net/21.15107/rcub_technorep_4195"
}
Mijatović, T., Milovanović, A., Sedmak, A., Milović, L.,& Čolić, K.. (2019). Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant. in Structural Integrity and Life
Society for Structural Integrity and Life, Institute for Material Testing., 19(3), 237-242.
https://hdl.handle.net/21.15107/rcub_technorep_4195
Mijatović T, Milovanović A, Sedmak A, Milović L, Čolić K. Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant. in Structural Integrity and Life. 2019;19(3):237-242.
https://hdl.handle.net/21.15107/rcub_technorep_4195 .
Mijatović, Tamara, Milovanović, Aleksa, Sedmak, Aleksandar, Milović, Ljubica, Čolić, Katarina, "Integrity assessment of reverse engineered ti-6al-4v eli total hip replacement implant" in Structural Integrity and Life, 19, no. 3 (2019):237-242,
https://hdl.handle.net/21.15107/rcub_technorep_4195 .
6
16

Analysis of fracture behaviour of thin s316l stainless steel plates

Čolić, Katarina; Gubeljak, Nenad; Burzić, Meri; Sedmak, Aleksandar; Mijatović, Tamara; Milovanović, Aleksa

(Institut za ispitivanje materijala, Beograd, 2017)

TY  - JOUR
AU  - Čolić, Katarina
AU  - Gubeljak, Nenad
AU  - Burzić, Meri
AU  - Sedmak, Aleksandar
AU  - Mijatović, Tamara
AU  - Milovanović, Aleksa
PY  - 2017
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5814
AB  - In this paper are presented experimental analyses of the behaviour of 316L stainless steel in regard to fracture, according to standard methods of investigation on modified tensile C(T) specimens. The S316L alloy is selected for this experimental analysis, often used in many engineering applications. This alloy is not prone to corrosion as other austenitic steels with a higher share of carbon. Results show that material behaviour, in terms of dependence of stress intensity factor (SIF) value relative to thickness of the plate, is necessary to assume with a different model when the specimen thickness is very small. Application of standards in the field of investigation of material resistance to fracture allow simultaneous determination and connection of several fracture mechanics parameters.
PB  - Institut za ispitivanje materijala, Beograd
T2  - Structural Integrity and Life
T1  - Analysis of fracture behaviour of thin s316l stainless steel plates
EP  - 216
IS  - 3
SP  - 211
VL  - 17
UR  - https://hdl.handle.net/21.15107/rcub_machinery_2732
ER  - 
@article{
author = "Čolić, Katarina and Gubeljak, Nenad and Burzić, Meri and Sedmak, Aleksandar and Mijatović, Tamara and Milovanović, Aleksa",
year = "2017",
abstract = "In this paper are presented experimental analyses of the behaviour of 316L stainless steel in regard to fracture, according to standard methods of investigation on modified tensile C(T) specimens. The S316L alloy is selected for this experimental analysis, often used in many engineering applications. This alloy is not prone to corrosion as other austenitic steels with a higher share of carbon. Results show that material behaviour, in terms of dependence of stress intensity factor (SIF) value relative to thickness of the plate, is necessary to assume with a different model when the specimen thickness is very small. Application of standards in the field of investigation of material resistance to fracture allow simultaneous determination and connection of several fracture mechanics parameters.",
publisher = "Institut za ispitivanje materijala, Beograd",
journal = "Structural Integrity and Life",
title = "Analysis of fracture behaviour of thin s316l stainless steel plates",
pages = "216-211",
number = "3",
volume = "17",
url = "https://hdl.handle.net/21.15107/rcub_machinery_2732"
}
Čolić, K., Gubeljak, N., Burzić, M., Sedmak, A., Mijatović, T.,& Milovanović, A.. (2017). Analysis of fracture behaviour of thin s316l stainless steel plates. in Structural Integrity and Life
Institut za ispitivanje materijala, Beograd., 17(3), 211-216.
https://hdl.handle.net/21.15107/rcub_machinery_2732
Čolić K, Gubeljak N, Burzić M, Sedmak A, Mijatović T, Milovanović A. Analysis of fracture behaviour of thin s316l stainless steel plates. in Structural Integrity and Life. 2017;17(3):211-216.
https://hdl.handle.net/21.15107/rcub_machinery_2732 .
Čolić, Katarina, Gubeljak, Nenad, Burzić, Meri, Sedmak, Aleksandar, Mijatović, Tamara, Milovanović, Aleksa, "Analysis of fracture behaviour of thin s316l stainless steel plates" in Structural Integrity and Life, 17, no. 3 (2017):211-216,
https://hdl.handle.net/21.15107/rcub_machinery_2732 .
5