Juranić, Zorica D.

Link to this page

Authority KeyName Variants
eea374c8-f0df-46e9-9ff6-bfc18d41ca9f
  • Juranić, Zorica D. (8)

Author's Bibliography

The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites

Surudžić, Rade; Janković, Ana; Mitrić, Miodrag; Matić, Ivana Z.; Juranić, Zorica D.; Živković, Ljiljana; Mišković-Stanković, Vesna; Rhee, Kyong Yop; Park, Soo Jin; Hui, David

(Elsevier Science Inc, New York, 2016)

TY  - JOUR
AU  - Surudžić, Rade
AU  - Janković, Ana
AU  - Mitrić, Miodrag
AU  - Matić, Ivana Z.
AU  - Juranić, Zorica D.
AU  - Živković, Ljiljana
AU  - Mišković-Stanković, Vesna
AU  - Rhee, Kyong Yop
AU  - Park, Soo Jin
AU  - Hui, David
PY  - 2016
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3397
AB  - Poly(vinyl alcohol)/graphene (PVA/Gr) nanocomposite was synthesized with the aim of developing a novel improved material. The PVA/Gr nanocomposite was characterized by UV-visible spectroscopy, cyclic voltammetry, Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy analyses, and the interaction of PVA molecules with graphene was examined. Introduction of Gr led to improved mechanical and thermal properties of the PVA/Gr nanocomposite compared to pure PVA, as well as strong antibacterial activity against the bacterial strain Staphylococcus aureus. The PVA/Gr nanocomposite was non-cytotoxic against healthy peripheral blood mononuclear cells by MTT assay, indicating its high potential for biomedical applications.
PB  - Elsevier Science Inc, New York
T2  - Journal of Industrial and Engineering Chemistry
T1  - The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites
EP  - 257
SP  - 250
VL  - 34
DO  - 10.1016/j.jiec.2015.11.016
ER  - 
@article{
author = "Surudžić, Rade and Janković, Ana and Mitrić, Miodrag and Matić, Ivana Z. and Juranić, Zorica D. and Živković, Ljiljana and Mišković-Stanković, Vesna and Rhee, Kyong Yop and Park, Soo Jin and Hui, David",
year = "2016",
abstract = "Poly(vinyl alcohol)/graphene (PVA/Gr) nanocomposite was synthesized with the aim of developing a novel improved material. The PVA/Gr nanocomposite was characterized by UV-visible spectroscopy, cyclic voltammetry, Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy analyses, and the interaction of PVA molecules with graphene was examined. Introduction of Gr led to improved mechanical and thermal properties of the PVA/Gr nanocomposite compared to pure PVA, as well as strong antibacterial activity against the bacterial strain Staphylococcus aureus. The PVA/Gr nanocomposite was non-cytotoxic against healthy peripheral blood mononuclear cells by MTT assay, indicating its high potential for biomedical applications.",
publisher = "Elsevier Science Inc, New York",
journal = "Journal of Industrial and Engineering Chemistry",
title = "The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites",
pages = "257-250",
volume = "34",
doi = "10.1016/j.jiec.2015.11.016"
}
Surudžić, R., Janković, A., Mitrić, M., Matić, I. Z., Juranić, Z. D., Živković, L., Mišković-Stanković, V., Rhee, K. Y., Park, S. J.,& Hui, D.. (2016). The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites. in Journal of Industrial and Engineering Chemistry
Elsevier Science Inc, New York., 34, 250-257.
https://doi.org/10.1016/j.jiec.2015.11.016
Surudžić R, Janković A, Mitrić M, Matić IZ, Juranić ZD, Živković L, Mišković-Stanković V, Rhee KY, Park SJ, Hui D. The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites. in Journal of Industrial and Engineering Chemistry. 2016;34:250-257.
doi:10.1016/j.jiec.2015.11.016 .
Surudžić, Rade, Janković, Ana, Mitrić, Miodrag, Matić, Ivana Z., Juranić, Zorica D., Živković, Ljiljana, Mišković-Stanković, Vesna, Rhee, Kyong Yop, Park, Soo Jin, Hui, David, "The effect of graphene loading on mechanical, thermal and biological properties of poly(vinyl alcohol)/graphene nanocomposites" in Journal of Industrial and Engineering Chemistry, 34 (2016):250-257,
https://doi.org/10.1016/j.jiec.2015.11.016 . .
58
44
56

Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid

Janković, Ana; Eraković, Sanja; Mitrić, Miodrag; Matić, Ivana Z.; Juranić, Zorica D.; Tsui, Gary C. P.; Tang, C. Y.; Mišković-Stanković, Vesna; Rhee, Kyong Yop; Park, Soo Jin

(Elsevier Science Sa, Lausanne, 2015)

TY  - JOUR
AU  - Janković, Ana
AU  - Eraković, Sanja
AU  - Mitrić, Miodrag
AU  - Matić, Ivana Z.
AU  - Juranić, Zorica D.
AU  - Tsui, Gary C. P.
AU  - Tang, C. Y.
AU  - Mišković-Stanković, Vesna
AU  - Rhee, Kyong Yop
AU  - Park, Soo Jin
PY  - 2015
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3006
AB  - The hydroxyapatite/graphene (HAP/Gr) composite was electrodeposited on Ti using the electrophoretic deposition process to obtain uniform bioactive coating with improved mechanical strength and favorable corrosion stability in simulated body fluid (SBF). Incorporation of Gr was verified by Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis. The HAP/Gr composite coating exhibited reduced surface cracks, nearly double the hardness, and elastic modulus increased by almost 50% compared to pure HAP coating, as estimated by a nanoindentation test. The bioactive HAP/Gr composite coating provided a newly formed apatite layer in SBF with enhanced corrosion stability, as evidenced by electrochemical impedance spectroscopy. The thermal stability of the HAP/Gr coating was improved in comparison to the pure HAP coating, and the Ca/P ratio was closer to the stoichiometric value. No antibacterial activity against Staphylococcus aureus or Escherichia coli could be verified. The HAP/Gr composite coating was classified as non-cytotoxic when tested against healthy peripheral blood mononuclear cells (PBMC).
PB  - Elsevier Science Sa, Lausanne
T2  - Journal of Alloys and Compounds
T1  - Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid
EP  - 157
SP  - 148
VL  - 624
DO  - 10.1016/j.jallcom.2014.11.078
ER  - 
@article{
author = "Janković, Ana and Eraković, Sanja and Mitrić, Miodrag and Matić, Ivana Z. and Juranić, Zorica D. and Tsui, Gary C. P. and Tang, C. Y. and Mišković-Stanković, Vesna and Rhee, Kyong Yop and Park, Soo Jin",
year = "2015",
abstract = "The hydroxyapatite/graphene (HAP/Gr) composite was electrodeposited on Ti using the electrophoretic deposition process to obtain uniform bioactive coating with improved mechanical strength and favorable corrosion stability in simulated body fluid (SBF). Incorporation of Gr was verified by Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis. The HAP/Gr composite coating exhibited reduced surface cracks, nearly double the hardness, and elastic modulus increased by almost 50% compared to pure HAP coating, as estimated by a nanoindentation test. The bioactive HAP/Gr composite coating provided a newly formed apatite layer in SBF with enhanced corrosion stability, as evidenced by electrochemical impedance spectroscopy. The thermal stability of the HAP/Gr coating was improved in comparison to the pure HAP coating, and the Ca/P ratio was closer to the stoichiometric value. No antibacterial activity against Staphylococcus aureus or Escherichia coli could be verified. The HAP/Gr composite coating was classified as non-cytotoxic when tested against healthy peripheral blood mononuclear cells (PBMC).",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Journal of Alloys and Compounds",
title = "Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid",
pages = "157-148",
volume = "624",
doi = "10.1016/j.jallcom.2014.11.078"
}
Janković, A., Eraković, S., Mitrić, M., Matić, I. Z., Juranić, Z. D., Tsui, G. C. P., Tang, C. Y., Mišković-Stanković, V., Rhee, K. Y.,& Park, S. J.. (2015). Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid. in Journal of Alloys and Compounds
Elsevier Science Sa, Lausanne., 624, 148-157.
https://doi.org/10.1016/j.jallcom.2014.11.078
Janković A, Eraković S, Mitrić M, Matić IZ, Juranić ZD, Tsui GCP, Tang CY, Mišković-Stanković V, Rhee KY, Park SJ. Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid. in Journal of Alloys and Compounds. 2015;624:148-157.
doi:10.1016/j.jallcom.2014.11.078 .
Janković, Ana, Eraković, Sanja, Mitrić, Miodrag, Matić, Ivana Z., Juranić, Zorica D., Tsui, Gary C. P., Tang, C. Y., Mišković-Stanković, Vesna, Rhee, Kyong Yop, Park, Soo Jin, "Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid" in Journal of Alloys and Compounds, 624 (2015):148-157,
https://doi.org/10.1016/j.jallcom.2014.11.078 . .
168
125
173

Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites

Jovanović, Željka; Radosavljević, Aleksandra; Kačarević-Popović, Zorica M.; Stojkovska, Jasmina; Perić-Grujić, Aleksandra; Ristić, Mirjana; Matić, Ivana Z.; Juranić, Zorica D.; Obradović, Bojana; Mišković-Stanković, Vesna

(Elsevier Science Bv, Amsterdam, 2013)

TY  - JOUR
AU  - Jovanović, Željka
AU  - Radosavljević, Aleksandra
AU  - Kačarević-Popović, Zorica M.
AU  - Stojkovska, Jasmina
AU  - Perić-Grujić, Aleksandra
AU  - Ristić, Mirjana
AU  - Matić, Ivana Z.
AU  - Juranić, Zorica D.
AU  - Obradović, Bojana
AU  - Mišković-Stanković, Vesna
PY  - 2013
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2538
AB  - Silver/poly(N-vinyl-2-pyrrolidone) (Ag/PVP) nanocomposites containing Ag nanoparticles at different concentrations were synthesized using gamma-irradiation. Cytotoxicity of the obtained nanocomposites was determined by MU assay in monolayer cultures of normal human immunocompetent peripheral blood mononuclear cells (PBMC) that were either non-stimulated or stimulated to proliferate by mitogen phytohemagglutinin (PHA), as well as in human cervix adenocarcinoma cell (HeLa) cultures. Silver release kinetics and mechanical properties of nanocomposites were investigated under bioreactor conditions in the simulated body fluid (SBF) at 37 degrees C. The release of silver was monitored under static conditions, and in two types of bioreactors: perfusion bioreactors and a bioreactor with dynamic compression coupled with SBF perfusion simulating in vivo conditions in articular cartilage. Ag/PVP nanocomposites exhibited slight cytotoxic effects against PBMC at the estimated concentration of 0.4 mu mol dm(-3), with negligible variations observed amongst different cell cultures investigated. Studies of the silver release kinetics indicated internal diffusion as the rate limiting step, determined by statistically comparable results obtained at all investigated conditions. However, silver release rate was slightly higher in the bioreactor with dynamic compression coupled with SBF perfusion as compared to the other two systems indicating the influence of dynamic compression. Modelling of silver release kinetics revealed potentials for optimization of Ag/PVP nanocomposites for particular applications as wound dressings or soft tissue implants.
PB  - Elsevier Science Bv, Amsterdam
T2  - Colloids and Surfaces B-Biointerfaces
T1  - Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites
EP  - 235
SP  - 230
VL  - 105
DO  - 10.1016/j.colsurfb.2012.12.055
ER  - 
@article{
author = "Jovanović, Željka and Radosavljević, Aleksandra and Kačarević-Popović, Zorica M. and Stojkovska, Jasmina and Perić-Grujić, Aleksandra and Ristić, Mirjana and Matić, Ivana Z. and Juranić, Zorica D. and Obradović, Bojana and Mišković-Stanković, Vesna",
year = "2013",
abstract = "Silver/poly(N-vinyl-2-pyrrolidone) (Ag/PVP) nanocomposites containing Ag nanoparticles at different concentrations were synthesized using gamma-irradiation. Cytotoxicity of the obtained nanocomposites was determined by MU assay in monolayer cultures of normal human immunocompetent peripheral blood mononuclear cells (PBMC) that were either non-stimulated or stimulated to proliferate by mitogen phytohemagglutinin (PHA), as well as in human cervix adenocarcinoma cell (HeLa) cultures. Silver release kinetics and mechanical properties of nanocomposites were investigated under bioreactor conditions in the simulated body fluid (SBF) at 37 degrees C. The release of silver was monitored under static conditions, and in two types of bioreactors: perfusion bioreactors and a bioreactor with dynamic compression coupled with SBF perfusion simulating in vivo conditions in articular cartilage. Ag/PVP nanocomposites exhibited slight cytotoxic effects against PBMC at the estimated concentration of 0.4 mu mol dm(-3), with negligible variations observed amongst different cell cultures investigated. Studies of the silver release kinetics indicated internal diffusion as the rate limiting step, determined by statistically comparable results obtained at all investigated conditions. However, silver release rate was slightly higher in the bioreactor with dynamic compression coupled with SBF perfusion as compared to the other two systems indicating the influence of dynamic compression. Modelling of silver release kinetics revealed potentials for optimization of Ag/PVP nanocomposites for particular applications as wound dressings or soft tissue implants.",
publisher = "Elsevier Science Bv, Amsterdam",
journal = "Colloids and Surfaces B-Biointerfaces",
title = "Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites",
pages = "235-230",
volume = "105",
doi = "10.1016/j.colsurfb.2012.12.055"
}
Jovanović, Ž., Radosavljević, A., Kačarević-Popović, Z. M., Stojkovska, J., Perić-Grujić, A., Ristić, M., Matić, I. Z., Juranić, Z. D., Obradović, B.,& Mišković-Stanković, V.. (2013). Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites. in Colloids and Surfaces B-Biointerfaces
Elsevier Science Bv, Amsterdam., 105, 230-235.
https://doi.org/10.1016/j.colsurfb.2012.12.055
Jovanović Ž, Radosavljević A, Kačarević-Popović ZM, Stojkovska J, Perić-Grujić A, Ristić M, Matić IZ, Juranić ZD, Obradović B, Mišković-Stanković V. Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites. in Colloids and Surfaces B-Biointerfaces. 2013;105:230-235.
doi:10.1016/j.colsurfb.2012.12.055 .
Jovanović, Željka, Radosavljević, Aleksandra, Kačarević-Popović, Zorica M., Stojkovska, Jasmina, Perić-Grujić, Aleksandra, Ristić, Mirjana, Matić, Ivana Z., Juranić, Zorica D., Obradović, Bojana, Mišković-Stanković, Vesna, "Bioreactor validation and biocompatibility of Ag/poly(N-vinyl-2-pyrrolidone) hydrogel nanocomposites" in Colloids and Surfaces B-Biointerfaces, 105 (2013):230-235,
https://doi.org/10.1016/j.colsurfb.2012.12.055 . .
25
27
26

Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium

Eraković, Sanja; Janković, Ana; Matić, Ivana Z.; Juranić, Zorica D.; Vukašinović-Sekulić, Maja; Stevanović, Tatjana; Mišković-Stanković, Vesna

(Elsevier Science Sa, Lausanne, 2013)

TY  - JOUR
AU  - Eraković, Sanja
AU  - Janković, Ana
AU  - Matić, Ivana Z.
AU  - Juranić, Zorica D.
AU  - Vukašinović-Sekulić, Maja
AU  - Stevanović, Tatjana
AU  - Mišković-Stanković, Vesna
PY  - 2013
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2447
AB  - Silver doped hydroxyapatite (HAP) [Ca9.95Ag0.05(PO4)(6)(OH)(2)] composite coatings with natural polymer organosolv lignin (Lig) were produced by electrophoretic deposition (EPD) on titanium. Coatings were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS). The corrosion stability of electrodeposited coatings was evaluated in vitro in Kokubo's simulated body fluid (SBF) at 37 degrees C using electrochemical impedance spectroscopy (EIS). Antimicrobial properties are directly proportional to the rate of silver ions release from the coatings, determined from inductively coupled plasma spectrometry (ICP-AES). The obtained results are in good agreement with viability of pathogenic bacteria strain Staphylococcus aureus TL in suspension, which had completely disappeared after 24 h. Composite Ag/HAP/Lig coatings were confirmed as non-toxic for healthy immunocompetent peripheral blood mononuclear cells (PBMC).
PB  - Elsevier Science Sa, Lausanne
T2  - Materials Chemistry and Physics
T1  - Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium
EP  - 530
IS  - 2-3
SP  - 521
VL  - 142
DO  - 10.1016/j.matchemphys.2013.07.047
ER  - 
@article{
author = "Eraković, Sanja and Janković, Ana and Matić, Ivana Z. and Juranić, Zorica D. and Vukašinović-Sekulić, Maja and Stevanović, Tatjana and Mišković-Stanković, Vesna",
year = "2013",
abstract = "Silver doped hydroxyapatite (HAP) [Ca9.95Ag0.05(PO4)(6)(OH)(2)] composite coatings with natural polymer organosolv lignin (Lig) were produced by electrophoretic deposition (EPD) on titanium. Coatings were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS). The corrosion stability of electrodeposited coatings was evaluated in vitro in Kokubo's simulated body fluid (SBF) at 37 degrees C using electrochemical impedance spectroscopy (EIS). Antimicrobial properties are directly proportional to the rate of silver ions release from the coatings, determined from inductively coupled plasma spectrometry (ICP-AES). The obtained results are in good agreement with viability of pathogenic bacteria strain Staphylococcus aureus TL in suspension, which had completely disappeared after 24 h. Composite Ag/HAP/Lig coatings were confirmed as non-toxic for healthy immunocompetent peripheral blood mononuclear cells (PBMC).",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Materials Chemistry and Physics",
title = "Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium",
pages = "530-521",
number = "2-3",
volume = "142",
doi = "10.1016/j.matchemphys.2013.07.047"
}
Eraković, S., Janković, A., Matić, I. Z., Juranić, Z. D., Vukašinović-Sekulić, M., Stevanović, T.,& Mišković-Stanković, V.. (2013). Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium. in Materials Chemistry and Physics
Elsevier Science Sa, Lausanne., 142(2-3), 521-530.
https://doi.org/10.1016/j.matchemphys.2013.07.047
Eraković S, Janković A, Matić IZ, Juranić ZD, Vukašinović-Sekulić M, Stevanović T, Mišković-Stanković V. Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium. in Materials Chemistry and Physics. 2013;142(2-3):521-530.
doi:10.1016/j.matchemphys.2013.07.047 .
Eraković, Sanja, Janković, Ana, Matić, Ivana Z., Juranić, Zorica D., Vukašinović-Sekulić, Maja, Stevanović, Tatjana, Mišković-Stanković, Vesna, "Investigation of silver impact on hydroxyapatite/lignin coatings electrodeposited on titanium" in Materials Chemistry and Physics, 142, no. 2-3 (2013):521-530,
https://doi.org/10.1016/j.matchemphys.2013.07.047 . .
39
37
41

In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads

Jovanović, Z.; Stojkovska, Jasmina; Vukašinović-Sekulić, Maja; Matić, I.; Juranić, Zorica D.; Obradović, B.; Mišković-Stanković, Vesna

(Wiley-Blackwell, Hoboken, 2012)

TY  - JOUR
AU  - Jovanović, Z.
AU  - Stojkovska, Jasmina
AU  - Vukašinović-Sekulić, Maja
AU  - Matić, I.
AU  - Juranić, Zorica D.
AU  - Obradović, B.
AU  - Mišković-Stanković, Vesna
PY  - 2012
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2117
PB  - Wiley-Blackwell, Hoboken
T2  - Journal of Tissue Engineering and Regenerative Medicine
T1  - In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads
EP  - 218
SP  - 218
VL  - 6
UR  - https://hdl.handle.net/21.15107/rcub_technorep_2117
ER  - 
@article{
author = "Jovanović, Z. and Stojkovska, Jasmina and Vukašinović-Sekulić, Maja and Matić, I. and Juranić, Zorica D. and Obradović, B. and Mišković-Stanković, Vesna",
year = "2012",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Journal of Tissue Engineering and Regenerative Medicine",
title = "In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads",
pages = "218-218",
volume = "6",
url = "https://hdl.handle.net/21.15107/rcub_technorep_2117"
}
Jovanović, Z., Stojkovska, J., Vukašinović-Sekulić, M., Matić, I., Juranić, Z. D., Obradović, B.,& Mišković-Stanković, V.. (2012). In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads. in Journal of Tissue Engineering and Regenerative Medicine
Wiley-Blackwell, Hoboken., 6, 218-218.
https://hdl.handle.net/21.15107/rcub_technorep_2117
Jovanović Z, Stojkovska J, Vukašinović-Sekulić M, Matić I, Juranić ZD, Obradović B, Mišković-Stanković V. In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads. in Journal of Tissue Engineering and Regenerative Medicine. 2012;6:218-218.
https://hdl.handle.net/21.15107/rcub_technorep_2117 .
Jovanović, Z., Stojkovska, Jasmina, Vukašinović-Sekulić, Maja, Matić, I., Juranić, Zorica D., Obradović, B., Mišković-Stanković, Vesna, "In vitro investigation of cytotoxicity and antimicrobial activity of silver/alginate nanocomposite microbeads" in Journal of Tissue Engineering and Regenerative Medicine, 6 (2012):218-218,
https://hdl.handle.net/21.15107/rcub_technorep_2117 .

Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants

Mišković-Stanković, Vesna; Eraković, Sanja; Surudžić, Rade; Veljović, Đorđe; Vukašinović-Sekulić, Maja; Matić, I.; Juranić, Zorica D.; Stevanović, T.

(Wiley-Blackwell, Hoboken, 2012)

TY  - JOUR
AU  - Mišković-Stanković, Vesna
AU  - Eraković, Sanja
AU  - Surudžić, Rade
AU  - Veljović, Đorđe
AU  - Vukašinović-Sekulić, Maja
AU  - Matić, I.
AU  - Juranić, Zorica D.
AU  - Stevanović, T.
PY  - 2012
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2118
PB  - Wiley-Blackwell, Hoboken
T2  - Journal of Tissue Engineering and Regenerative Medicine
T1  - Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants
EP  - 235
SP  - 235
VL  - 6
UR  - https://hdl.handle.net/21.15107/rcub_technorep_2118
ER  - 
@article{
author = "Mišković-Stanković, Vesna and Eraković, Sanja and Surudžić, Rade and Veljović, Đorđe and Vukašinović-Sekulić, Maja and Matić, I. and Juranić, Zorica D. and Stevanović, T.",
year = "2012",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Journal of Tissue Engineering and Regenerative Medicine",
title = "Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants",
pages = "235-235",
volume = "6",
url = "https://hdl.handle.net/21.15107/rcub_technorep_2118"
}
Mišković-Stanković, V., Eraković, S., Surudžić, R., Veljović, Đ., Vukašinović-Sekulić, M., Matić, I., Juranić, Z. D.,& Stevanović, T.. (2012). Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants. in Journal of Tissue Engineering and Regenerative Medicine
Wiley-Blackwell, Hoboken., 6, 235-235.
https://hdl.handle.net/21.15107/rcub_technorep_2118
Mišković-Stanković V, Eraković S, Surudžić R, Veljović Đ, Vukašinović-Sekulić M, Matić I, Juranić ZD, Stevanović T. Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants. in Journal of Tissue Engineering and Regenerative Medicine. 2012;6:235-235.
https://hdl.handle.net/21.15107/rcub_technorep_2118 .
Mišković-Stanković, Vesna, Eraković, Sanja, Surudžić, Rade, Veljović, Đorđe, Vukašinović-Sekulić, Maja, Matić, I., Juranić, Zorica D., Stevanović, T., "Electrophoretic deposition of bioactive nanocomposite coatings on titanium as a hard tissue implants" in Journal of Tissue Engineering and Regenerative Medicine, 6 (2012):235-235,
https://hdl.handle.net/21.15107/rcub_technorep_2118 .

Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid

Eraković, Sanja; Surudžić, Rade; Veljović, Đorđe; Stevanović, T.; Vukašinović-Sekulić, Maja; Matić, I.; Juranić, Zorica D.; Mišković-Stanković, Vesna

(Wiley-Blackwell, Hoboken, 2012)

TY  - JOUR
AU  - Eraković, Sanja
AU  - Surudžić, Rade
AU  - Veljović, Đorđe
AU  - Stevanović, T.
AU  - Vukašinović-Sekulić, Maja
AU  - Matić, I.
AU  - Juranić, Zorica D.
AU  - Mišković-Stanković, Vesna
PY  - 2012
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2116
PB  - Wiley-Blackwell, Hoboken
T2  - Journal of Tissue Engineering and Regenerative Medicine
T1  - Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid
EP  - 210
SP  - 210
VL  - 6
UR  - https://hdl.handle.net/21.15107/rcub_technorep_2116
ER  - 
@article{
author = "Eraković, Sanja and Surudžić, Rade and Veljović, Đorđe and Stevanović, T. and Vukašinović-Sekulić, Maja and Matić, I. and Juranić, Zorica D. and Mišković-Stanković, Vesna",
year = "2012",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Journal of Tissue Engineering and Regenerative Medicine",
title = "Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid",
pages = "210-210",
volume = "6",
url = "https://hdl.handle.net/21.15107/rcub_technorep_2116"
}
Eraković, S., Surudžić, R., Veljović, Đ., Stevanović, T., Vukašinović-Sekulić, M., Matić, I., Juranić, Z. D.,& Mišković-Stanković, V.. (2012). Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid. in Journal of Tissue Engineering and Regenerative Medicine
Wiley-Blackwell, Hoboken., 6, 210-210.
https://hdl.handle.net/21.15107/rcub_technorep_2116
Eraković S, Surudžić R, Veljović Đ, Stevanović T, Vukašinović-Sekulić M, Matić I, Juranić ZD, Mišković-Stanković V. Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid. in Journal of Tissue Engineering and Regenerative Medicine. 2012;6:210-210.
https://hdl.handle.net/21.15107/rcub_technorep_2116 .
Eraković, Sanja, Surudžić, Rade, Veljović, Đorđe, Stevanović, T., Vukašinović-Sekulić, Maja, Matić, I., Juranić, Zorica D., Mišković-Stanković, Vesna, "Corrosion stability of silver-doped hydroxyapatite/lignin coatings in simulated body fluid" in Journal of Tissue Engineering and Regenerative Medicine, 6 (2012):210-210,
https://hdl.handle.net/21.15107/rcub_technorep_2116 .

The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium

Eraković, Sanja; Veljović, Đorđe; Diouf, Papa Niokhor; Stevanović, Tatjana; Mitrić, Miodrag; Janaćković, Đorđe; Matić, Ivana Z.; Juranić, Zorica D.; Mišković-Stanković, Vesna

(Elsevier Science Sa, Lausanne, 2012)

TY  - JOUR
AU  - Eraković, Sanja
AU  - Veljović, Đorđe
AU  - Diouf, Papa Niokhor
AU  - Stevanović, Tatjana
AU  - Mitrić, Miodrag
AU  - Janaćković, Đorđe
AU  - Matić, Ivana Z.
AU  - Juranić, Zorica D.
AU  - Mišković-Stanković, Vesna
PY  - 2012
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2181
AB  - Composite coatings based on lignin, obtained by electrophoretic deposition (EPD) on titanium, were investigated. The aim of this work was to produce hydroxyapatite/lignin (HAP/Lig) coatings on titanium and to investigate the effect of the lignin concentration on microstructure, morphology, phase composition, thermal behavior and cytotoxicity of the HAP/Lig coatings. An organosolv lignin was used for the production of the composite coatings studied in this research. The properties of HAP/Lig coatings were characterized using X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), thermogravimetric analysis (TGA), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FT-IR) and X-ray photoelectron spectroscopy (XPS), as well as the MTT test of cytotoxicity. The results showed that higher lignin concentrations protected the HAP lattice during sintering, thereby improving the stability of the HAP/Lig coatings. The cell survival of peripheral blood mononuclear cells (PBMC) after proliferation indicates that the HAP/Lig coating with 1 wt% Lig electrodeposited on titanium was non-toxic with significant promise as a potential bone-repair material.
PB  - Elsevier Science Sa, Lausanne
T2  - Progress in Organic Coatings
T1  - The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium
EP  - 283
IS  - 4
SP  - 275
VL  - 75
DO  - 10.1016/j.porgcoat.2012.07.005
ER  - 
@article{
author = "Eraković, Sanja and Veljović, Đorđe and Diouf, Papa Niokhor and Stevanović, Tatjana and Mitrić, Miodrag and Janaćković, Đorđe and Matić, Ivana Z. and Juranić, Zorica D. and Mišković-Stanković, Vesna",
year = "2012",
abstract = "Composite coatings based on lignin, obtained by electrophoretic deposition (EPD) on titanium, were investigated. The aim of this work was to produce hydroxyapatite/lignin (HAP/Lig) coatings on titanium and to investigate the effect of the lignin concentration on microstructure, morphology, phase composition, thermal behavior and cytotoxicity of the HAP/Lig coatings. An organosolv lignin was used for the production of the composite coatings studied in this research. The properties of HAP/Lig coatings were characterized using X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), thermogravimetric analysis (TGA), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FT-IR) and X-ray photoelectron spectroscopy (XPS), as well as the MTT test of cytotoxicity. The results showed that higher lignin concentrations protected the HAP lattice during sintering, thereby improving the stability of the HAP/Lig coatings. The cell survival of peripheral blood mononuclear cells (PBMC) after proliferation indicates that the HAP/Lig coating with 1 wt% Lig electrodeposited on titanium was non-toxic with significant promise as a potential bone-repair material.",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Progress in Organic Coatings",
title = "The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium",
pages = "283-275",
number = "4",
volume = "75",
doi = "10.1016/j.porgcoat.2012.07.005"
}
Eraković, S., Veljović, Đ., Diouf, P. N., Stevanović, T., Mitrić, M., Janaćković, Đ., Matić, I. Z., Juranić, Z. D.,& Mišković-Stanković, V.. (2012). The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium. in Progress in Organic Coatings
Elsevier Science Sa, Lausanne., 75(4), 275-283.
https://doi.org/10.1016/j.porgcoat.2012.07.005
Eraković S, Veljović Đ, Diouf PN, Stevanović T, Mitrić M, Janaćković Đ, Matić IZ, Juranić ZD, Mišković-Stanković V. The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium. in Progress in Organic Coatings. 2012;75(4):275-283.
doi:10.1016/j.porgcoat.2012.07.005 .
Eraković, Sanja, Veljović, Đorđe, Diouf, Papa Niokhor, Stevanović, Tatjana, Mitrić, Miodrag, Janaćković, Đorđe, Matić, Ivana Z., Juranić, Zorica D., Mišković-Stanković, Vesna, "The effect of lignin on the structure and characteristics of composite coatings electrodeposited on titanium" in Progress in Organic Coatings, 75, no. 4 (2012):275-283,
https://doi.org/10.1016/j.porgcoat.2012.07.005 . .
23
26
29