@conference{
author = "Bugarinović, Aleksandar and Srećković, Milesa and Jovanović, Dražen and Malović, Miodrag and Karastojković, Zoran and Drobnjak, Petar and Mirjanić, Vladan and Mirjanić, Đorđe",
year = "2023",
abstract = "Postoje problemi koji treba da se rešavaju u nekoliko različitih grana medicine (fizikalna terapija, dermatologija, uopšteno medicina, uključujući stomatologiju, oftalmologiju i otorinolaringologiju i dr). Ako se koristi prednost različitih snopnih tehnika, pojavljuju se prirodno, iste potrebe i u sferi industrije, heritologije, forenzike. Na drugi način pojavljuje se trend da se, objedinjeno, koriste generalno ista rešenja sa modifikacijama u konkretnoj primeni. U radu je poseban akcent posvećen koherentnom elektromagnetnom zračenju, zadacima u vezi prilaza pojedinačnom slučaju, tehničkoj podršci softverske i hardverske prirode i dati su izabrani rezultati pojedinih interakcija ili slučajeva dobijene modulacije u širem smislu. Posmatran je i izabran potreban teoretski prilaz, kao baza za procenu objektivnih uslova, koji mogu da utiču pozitivno / negativno na dati tretman ili dijagnostiku., There are problems that need to be solved for several different
branches of medicine (physical therapy, dermatology, medicine in
general, including dentistry, ophthalmology and
otorhinolaryngology, etc.). If the advantage of various beam
techniques is used, the same needs naturally appear in the sphere of
industry, heritology, and forensics.In order to obtain target
information on the time intervals of therapy, diagnostics and
modulation, it must be taken into account that each treatment of
individuals is a case for itself, related to the general premises of
appropriate dosimetry. That is why in the software there is a large
number of tasks for the operation and inclusion of all parameters
related to a particular case and for intrusions into the often selfstandardized protocols, which are found in the instructions for the
acquisition of new systems, related to Elion techniques. In another
way, there is a trend to use, unitedly, generally the same solutions
with modifications in specific application.
In the paper, a special accent is devoted to coherent
electromagnetic radiation, tasks related to the approach to individual
cases, technical support of a software and hardware nature, and
selected results of individual interactions or cases of received
modulation in a broader sense are given. The necessary theoretical
approach was observed and selected, as a basis for evaluating
objective conditions, which can have a positive / negative effect on
a given treatment or diagnosis.",
publisher = "Beograd : Društvo za ETRAN, Beograd : Akademska misao",
journal = "Zbornik radova / LXVII konferencija ETRAN, Istočno Sarajevo, BiH, 05 - 08.06.2023.",
title = "Odabrane primene snopnih tehnika kao tehnička podrška u dijagnostici, modifikaciji materijala i karakterizaciji, Selected applications of beam techniques as technical support in diagnostics, material modification and characterization",
url = "https://hdl.handle.net/21.15107/rcub_technorep_7160"
}