Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids

Stanimirović, Andrej M.; Živković, Emila; Miloavić, Nenad D.; Kijevčanin, Mirjana

(Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd, 2017)

TY  - JOUR
AU  - Stanimirović, Andrej M.
AU  - Živković, Emila
AU  - Miloavić, Nenad D.
AU  - Kijevčanin, Mirjana
PY  - 2017
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3732
AB  - Transient hot wire method is considered a reliable and precise technique for measuring the thermal conductivity of liquids. The present paper describes a new transient hot wire experimental set-up and its initial testing. The new apparatus was tested by performing thermal conductivity measurements on substances whose reference thermophysical properties data existed in literature, namely on pure toluene and double distilled deionized water. The values of thermal conductivity measured in the temperature range 25 to 45 degrees C deviated +2.2% to +3% from the literature data, while the expanded measurement uncertainty was estimated to be +/- 4%.
PB  - Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd
T2  - Thermal Science
T1  - Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids
EP  - 1202
IS  - 3
SP  - 1195
VL  - 21
DO  - 10.2298/TSCI160324219S
ER  - 
@article{
author = "Stanimirović, Andrej M. and Živković, Emila and Miloavić, Nenad D. and Kijevčanin, Mirjana",
year = "2017",
abstract = "Transient hot wire method is considered a reliable and precise technique for measuring the thermal conductivity of liquids. The present paper describes a new transient hot wire experimental set-up and its initial testing. The new apparatus was tested by performing thermal conductivity measurements on substances whose reference thermophysical properties data existed in literature, namely on pure toluene and double distilled deionized water. The values of thermal conductivity measured in the temperature range 25 to 45 degrees C deviated +2.2% to +3% from the literature data, while the expanded measurement uncertainty was estimated to be +/- 4%.",
publisher = "Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd",
journal = "Thermal Science",
title = "Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids",
pages = "1202-1195",
number = "3",
volume = "21",
doi = "10.2298/TSCI160324219S"
}
Stanimirović, A. M., Živković, E., Miloavić, N. D.,& Kijevčanin, M.. (2017). Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids. in Thermal Science
Univerzitet u Beogradu - Institut za nuklearne nauke Vinča, Beograd., 21(3), 1195-1202.
https://doi.org/10.2298/TSCI160324219S
Stanimirović AM, Živković E, Miloavić ND, Kijevčanin M. Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids. in Thermal Science. 2017;21(3):1195-1202.
doi:10.2298/TSCI160324219S .
Stanimirović, Andrej M., Živković, Emila, Miloavić, Nenad D., Kijevčanin, Mirjana, "Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids" in Thermal Science, 21, no. 3 (2017):1195-1202,
https://doi.org/10.2298/TSCI160324219S . .
4