Urosević, Ivan

Link to this page

Authority KeyName Variants
22c28851-8b7f-45d6-94a5-34d4d525979e
  • Urosević, Ivan (2)
Projects
No records found.

Author's Bibliography

Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux

Urosević, Tijana; Povrenović, Dragan; Vukosavljević, Predrag; Urosević, Ivan

(Savez hemijskih inženjera, Beograd, 2018)

TY  - JOUR
AU  - Urosević, Tijana
AU  - Povrenović, Dragan
AU  - Vukosavljević, Predrag
AU  - Urosević, Ivan
PY  - 2018
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3897
AB  - In this paper, the influence of operating parameters (transmembrane pressure, temperature, the flow rate of retentate) on the cross - flow microfiltration of synthetic fruit juice and periodic backwashing with air was examined. In the experiments, the Kerasep W5 ceramic membrane with a separation limit of 0.2 mu m was used. The results of experiments in which different transmembrane pressures were used showed that stationary fluxes, at stationary conditions, after 60 minutes, have similar values. So, it can be concluded that the value of the driving force is irrelevant at steady state conditions. However, until the steady state conditions are established, a positive effect of the increase in the driving force is opposed to the negative effect of the increased polarization resistance, as a result of the driving force increase. Thus, the optimal transmembrane pressure was determined amounting to 2 bars. The optimum temperature of the process of clearing the fruit juices by microfiltration is reported as 55 degrees C. Higher temperatures are not used due to a degrading effect on the chemical composition of the juice and a long microfiltration process. With an increase in the temperature of retentate from 22 degrees C to 55 degrees C, the permeate flux increased up to 60 %. Increasing the flow rate of retentate reduces the thickness of the formed layer on the surface of the membrane. Due to limitations of the experimental setup and the large surface area of the membrane, the specific velocity of the retentate was low, so that the effects of cross-flow filtration were absent. The use of cross-flow filtration is one of the main requirements for increasing permeate flux, but in the present case it was in overall insufficient, so we have applied periodic air backwashing for improving fruit juice flux during membrane clarification. With this technique, the deposited layer on the membrane is lifted and the permeate flux is maintained at high levels preventing establishment of the steady state in the low flux zone. The time spent for the periodic backwashing was low as compared to the benefits of the increase in the collected permeate quantity. In all experiments with periodic backwashing with air, the collected permeate quantity is higher for up to 72.5 % as compared to experiments without backwashing. By increasing the backwashing duration, the flux increase is up to 5 %, which can be significant for microfiltration at industrial scale. Therefore, this technique is certainly recommended for microfiltration in the production of fruit juices.
PB  - Savez hemijskih inženjera, Beograd
T2  - Hemijska industrija
T1  - Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux
EP  - 68
IS  - 2
SP  - 59
VL  - 72
DO  - 10.2298/HEMIND170814021U
ER  - 
@article{
author = "Urosević, Tijana and Povrenović, Dragan and Vukosavljević, Predrag and Urosević, Ivan",
year = "2018",
abstract = "In this paper, the influence of operating parameters (transmembrane pressure, temperature, the flow rate of retentate) on the cross - flow microfiltration of synthetic fruit juice and periodic backwashing with air was examined. In the experiments, the Kerasep W5 ceramic membrane with a separation limit of 0.2 mu m was used. The results of experiments in which different transmembrane pressures were used showed that stationary fluxes, at stationary conditions, after 60 minutes, have similar values. So, it can be concluded that the value of the driving force is irrelevant at steady state conditions. However, until the steady state conditions are established, a positive effect of the increase in the driving force is opposed to the negative effect of the increased polarization resistance, as a result of the driving force increase. Thus, the optimal transmembrane pressure was determined amounting to 2 bars. The optimum temperature of the process of clearing the fruit juices by microfiltration is reported as 55 degrees C. Higher temperatures are not used due to a degrading effect on the chemical composition of the juice and a long microfiltration process. With an increase in the temperature of retentate from 22 degrees C to 55 degrees C, the permeate flux increased up to 60 %. Increasing the flow rate of retentate reduces the thickness of the formed layer on the surface of the membrane. Due to limitations of the experimental setup and the large surface area of the membrane, the specific velocity of the retentate was low, so that the effects of cross-flow filtration were absent. The use of cross-flow filtration is one of the main requirements for increasing permeate flux, but in the present case it was in overall insufficient, so we have applied periodic air backwashing for improving fruit juice flux during membrane clarification. With this technique, the deposited layer on the membrane is lifted and the permeate flux is maintained at high levels preventing establishment of the steady state in the low flux zone. The time spent for the periodic backwashing was low as compared to the benefits of the increase in the collected permeate quantity. In all experiments with periodic backwashing with air, the collected permeate quantity is higher for up to 72.5 % as compared to experiments without backwashing. By increasing the backwashing duration, the flux increase is up to 5 %, which can be significant for microfiltration at industrial scale. Therefore, this technique is certainly recommended for microfiltration in the production of fruit juices.",
publisher = "Savez hemijskih inženjera, Beograd",
journal = "Hemijska industrija",
title = "Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux",
pages = "68-59",
number = "2",
volume = "72",
doi = "10.2298/HEMIND170814021U"
}
Urosević, T., Povrenović, D., Vukosavljević, P.,& Urosević, I.. (2018). Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux. in Hemijska industrija
Savez hemijskih inženjera, Beograd., 72(2), 59-68.
https://doi.org/10.2298/HEMIND170814021U
Urosević T, Povrenović D, Vukosavljević P, Urosević I. Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux. in Hemijska industrija. 2018;72(2):59-68.
doi:10.2298/HEMIND170814021U .
Urosević, Tijana, Povrenović, Dragan, Vukosavljević, Predrag, Urosević, Ivan, "Microfiltration with periodic gas backwashing as an alternative technique for increasing permeate flux" in Hemijska industrija, 72, no. 2 (2018):59-68,
https://doi.org/10.2298/HEMIND170814021U . .

Recent developments in microfiltration and ultrafiltration of fruit juices

Urosević, Tijana; Povrenović, Dragan; Vukosavljević, Predrag; Urosević, Ivan; Stevanović, Snežana

(Elsevier, Amsterdam, 2017)

TY  - JOUR
AU  - Urosević, Tijana
AU  - Povrenović, Dragan
AU  - Vukosavljević, Predrag
AU  - Urosević, Ivan
AU  - Stevanović, Snežana
PY  - 2017
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3598
AB  - This article provides an overview of recent developments and the published literature in microfiltration (MF) and ultrafiltration (UF) of fruit juices. In this review, we summarize studies by relating basic concepts of membrane filtration with reported results and outlining the important factors to consider in the practical use of MF and UF. The important factors influencing the filtration rate and product quality are type of feed solution (type of fruit juice), membrane selection and operating parameters (temperature, transmembrane pressure, cross-flow velocity and volume concentration ratio). According to physicochemical and sensory tests confirmed by many types of research, juices produced by membrane filtration are of an excellent quality. Membrane fouling is a critical issue and inhibits the wider application of membranes in the fruit juice industry. The use of cross-flow filtration is one of the main requirements for increasing permeate flux, but overall insufficient, so we considered various techniques (enzymatic pretreatment, mechanical and electrical techniques) for improving fruit juice flux during membrane clarification.
PB  - Elsevier, Amsterdam
T2  - Food and Bioproducts Processing
T1  - Recent developments in microfiltration and ultrafiltration of fruit juices
EP  - 161
SP  - 147
VL  - 106
DO  - 10.1016/j.fbp.2017.09.009
ER  - 
@article{
author = "Urosević, Tijana and Povrenović, Dragan and Vukosavljević, Predrag and Urosević, Ivan and Stevanović, Snežana",
year = "2017",
abstract = "This article provides an overview of recent developments and the published literature in microfiltration (MF) and ultrafiltration (UF) of fruit juices. In this review, we summarize studies by relating basic concepts of membrane filtration with reported results and outlining the important factors to consider in the practical use of MF and UF. The important factors influencing the filtration rate and product quality are type of feed solution (type of fruit juice), membrane selection and operating parameters (temperature, transmembrane pressure, cross-flow velocity and volume concentration ratio). According to physicochemical and sensory tests confirmed by many types of research, juices produced by membrane filtration are of an excellent quality. Membrane fouling is a critical issue and inhibits the wider application of membranes in the fruit juice industry. The use of cross-flow filtration is one of the main requirements for increasing permeate flux, but overall insufficient, so we considered various techniques (enzymatic pretreatment, mechanical and electrical techniques) for improving fruit juice flux during membrane clarification.",
publisher = "Elsevier, Amsterdam",
journal = "Food and Bioproducts Processing",
title = "Recent developments in microfiltration and ultrafiltration of fruit juices",
pages = "161-147",
volume = "106",
doi = "10.1016/j.fbp.2017.09.009"
}
Urosević, T., Povrenović, D., Vukosavljević, P., Urosević, I.,& Stevanović, S.. (2017). Recent developments in microfiltration and ultrafiltration of fruit juices. in Food and Bioproducts Processing
Elsevier, Amsterdam., 106, 147-161.
https://doi.org/10.1016/j.fbp.2017.09.009
Urosević T, Povrenović D, Vukosavljević P, Urosević I, Stevanović S. Recent developments in microfiltration and ultrafiltration of fruit juices. in Food and Bioproducts Processing. 2017;106:147-161.
doi:10.1016/j.fbp.2017.09.009 .
Urosević, Tijana, Povrenović, Dragan, Vukosavljević, Predrag, Urosević, Ivan, Stevanović, Snežana, "Recent developments in microfiltration and ultrafiltration of fruit juices" in Food and Bioproducts Processing, 106 (2017):147-161,
https://doi.org/10.1016/j.fbp.2017.09.009 . .
62
30
66