Avramov Ivić, Milka

Link to this page

Authority KeyName Variants
45716d80-4308-444a-af4f-f3001782bf55
  • Avramov Ivić, Milka (1)
Projects

Author's Bibliography

Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin

Turuntaš, Nikola; Mutić, Sanja; Avramov Ivić, Milka; Eraković Pantović, Sanja; Mijin, Dušan; Petrović, Slobodan; Anojčić, Jasmina

(Belgrade : Faculty of Chemistry, 2023)

TY  - CONF
AU  - Turuntaš, Nikola
AU  - Mutić, Sanja
AU  - Avramov Ivić, Milka
AU  - Eraković Pantović, Sanja
AU  - Mijin, Dušan
AU  - Petrović, Slobodan
AU  - Anojčić, Jasmina
PY  - 2023
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/6951
AB  - The anticholinergic drug, solifenacin (SOL), is frequently used for the treatments in urological
tract for urinary incontinence, and urinary frequency [1]. As an electroactive molecule, SOL can
be an appropriate target analyte for voltammetric measurements. Boron doped diamond
electrode (BDDE) was selected as a working electrode because of its unique electrochemical
properties and emphasis on anodic measurements [2]. Prior to the voltammetric measurements
of SOL, BDDE was electrochemically activated in the supporting electrolyte by anodic
pretreatment (+2.0 V; 30 s) to achieve an oxygen terminated surface [3]. The voltammetric
behavior of SOL was investigated by cyclic voltammetry (CV) and differential pulse voltammetry
(DPV) in a model system. Based on the CV measurements it is proved that the certain electrooxidation process is diffusion controlled. Various experimental parameters were optimized
including the pH of the aqueous Britton-Robinson (B-R) buffer as a supporting electrolyte (from
pH 2.0 to 11.98) in the potential range from -0.3 V to 1.6 V vs saturated calomel electrode.
Depending on the pH value of the B-R buffer one oxidation peak of SOL was obtained at maxima
of peak potential around 1.1 V. The most intensive peak of the target analyte was at pH 11.0 which
was chosen as an optimal pH value for further measurements. Based on the correlation of SOL
peak intensity and different concentrations, the developed DPV method was characterized by a
linear concentration range from 0.015 to 0.907 µg mL-1, coefficient correlation of 0.999, and
relative standard deviation of 0.33%. Taking into account the sensitivity of the developed DPV
method towards the electrochemical oxidation of SOL, a very low detection limit of 0.005 µg mL-1
in the model system is achieved. The BDDE showed adequate selectivity for SOL in the presence
of investigated interferents. The obtained results indicate that BDDE with an optimized DPV
method could be applied for the trace-level electroanalytical determination of SOL in real samples.
PB  - Belgrade : Faculty of Chemistry
C3  - Book of Abstracts / 28th Young Investigators' Seminar on Analytical Chemistry, YISAC 2023, June 25th-28th, 2023, Belgrade
T1  - Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin
SP  - 24
UR  - https://hdl.handle.net/21.15107/rcub_technorep_6951
ER  - 
@conference{
author = "Turuntaš, Nikola and Mutić, Sanja and Avramov Ivić, Milka and Eraković Pantović, Sanja and Mijin, Dušan and Petrović, Slobodan and Anojčić, Jasmina",
year = "2023",
abstract = "The anticholinergic drug, solifenacin (SOL), is frequently used for the treatments in urological
tract for urinary incontinence, and urinary frequency [1]. As an electroactive molecule, SOL can
be an appropriate target analyte for voltammetric measurements. Boron doped diamond
electrode (BDDE) was selected as a working electrode because of its unique electrochemical
properties and emphasis on anodic measurements [2]. Prior to the voltammetric measurements
of SOL, BDDE was electrochemically activated in the supporting electrolyte by anodic
pretreatment (+2.0 V; 30 s) to achieve an oxygen terminated surface [3]. The voltammetric
behavior of SOL was investigated by cyclic voltammetry (CV) and differential pulse voltammetry
(DPV) in a model system. Based on the CV measurements it is proved that the certain electrooxidation process is diffusion controlled. Various experimental parameters were optimized
including the pH of the aqueous Britton-Robinson (B-R) buffer as a supporting electrolyte (from
pH 2.0 to 11.98) in the potential range from -0.3 V to 1.6 V vs saturated calomel electrode.
Depending on the pH value of the B-R buffer one oxidation peak of SOL was obtained at maxima
of peak potential around 1.1 V. The most intensive peak of the target analyte was at pH 11.0 which
was chosen as an optimal pH value for further measurements. Based on the correlation of SOL
peak intensity and different concentrations, the developed DPV method was characterized by a
linear concentration range from 0.015 to 0.907 µg mL-1, coefficient correlation of 0.999, and
relative standard deviation of 0.33%. Taking into account the sensitivity of the developed DPV
method towards the electrochemical oxidation of SOL, a very low detection limit of 0.005 µg mL-1
in the model system is achieved. The BDDE showed adequate selectivity for SOL in the presence
of investigated interferents. The obtained results indicate that BDDE with an optimized DPV
method could be applied for the trace-level electroanalytical determination of SOL in real samples.",
publisher = "Belgrade : Faculty of Chemistry",
journal = "Book of Abstracts / 28th Young Investigators' Seminar on Analytical Chemistry, YISAC 2023, June 25th-28th, 2023, Belgrade",
title = "Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin",
pages = "24",
url = "https://hdl.handle.net/21.15107/rcub_technorep_6951"
}
Turuntaš, N., Mutić, S., Avramov Ivić, M., Eraković Pantović, S., Mijin, D., Petrović, S.,& Anojčić, J.. (2023). Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin. in Book of Abstracts / 28th Young Investigators' Seminar on Analytical Chemistry, YISAC 2023, June 25th-28th, 2023, Belgrade
Belgrade : Faculty of Chemistry., 24.
https://hdl.handle.net/21.15107/rcub_technorep_6951
Turuntaš N, Mutić S, Avramov Ivić M, Eraković Pantović S, Mijin D, Petrović S, Anojčić J. Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin. in Book of Abstracts / 28th Young Investigators' Seminar on Analytical Chemistry, YISAC 2023, June 25th-28th, 2023, Belgrade. 2023;:24.
https://hdl.handle.net/21.15107/rcub_technorep_6951 .
Turuntaš, Nikola, Mutić, Sanja, Avramov Ivić, Milka, Eraković Pantović, Sanja, Mijin, Dušan, Petrović, Slobodan, Anojčić, Jasmina, "Electroanalytical performance of boron doped diamond electrode for the determination of solifenacin" in Book of Abstracts / 28th Young Investigators' Seminar on Analytical Chemistry, YISAC 2023, June 25th-28th, 2023, Belgrade (2023):24,
https://hdl.handle.net/21.15107/rcub_technorep_6951 .