Avramov Ivić, Milka

Link to this page

Authority KeyName Variants
4a016c37-0c6e-4e86-a964-9a3f54b28843
  • Avramov Ivić, Milka (2)
  • Avramov-Ivić, Milka (1)

Author's Bibliography

Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination

Anojčić, Jasmina; Mijin, Dušan; Eraković Pantović, Sanja; Bogdanović, Aleksandra; Turuntaš, Nikola; Mutić, Sanja; Petrović, Slobodan; Avramov Ivić, Milka

(Elsevier B.V., 2024-03)

TY  - JOUR
AU  - Anojčić, Jasmina
AU  - Mijin, Dušan
AU  - Eraković Pantović, Sanja
AU  - Bogdanović, Aleksandra
AU  - Turuntaš, Nikola
AU  - Mutić, Sanja
AU  - Petrović, Slobodan
AU  - Avramov Ivić, Milka
PY  - 2024-03
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7278
AB  - The anticholinergic drug, solifenacin, is frequently used for the treatment of the urological tract for urinary incontinence, and urinary frequency. The development of reliable and effective solifenacin electrochemical sensors is of great importance for the pharmaceutical industry and clinical practice. In this work, the electrochemical behavior of solifenacin succinate (SOL) was studied using three different working electrodes: gold (Au), glassy carbon (GCE) and boron-doped diamond electrode (BDDE). The cyclic voltammetric (CV) measurements performed in 0.05 M NaHCO3 indicated that the SOL oxidation process is irreversible and diffusion-controlled at all investigated working electrodes. Afterwards, the testing of SOL electrochemical stability and the possibility of its electrochemical degradation was performed at the Au electrode by the cycling of the potential during 3 h and continuously to 6 h. It was shown that the SOL was electrochemically transformed into another electroactive species and its degradation was excluded. For electroanalytical application, the anodically pretreated BDDE (+2.0 V; 30 s) was selected. Various experimental parameters were optimized, including the pH of the aqueous Britton-Robinson (B-R) buffer as a supporting electrolyte (from pH 2.0 to 11.98) and the most intensive peak of the target analyte was at pH 11.0, so this pH value was chosen as the optimum for further measurements. Based on the correlation of the SOL peak intensity and different concentrations, the developed differential pulse voltammetric (DPV) method was characterized by a linear concentration range from 0.041 to 2.50 µM, with a correlation coefficient of 0.999, and a relative standard deviation of 0.3 %. Taking into account the sensitivity of the developed DPV method towards the electrochemical oxidation of SOL, a very low detection limit of 0.012 µM in the model system was achieved. The BDDE showed adequate selectivity for SOL in the presence of the investigated interferents. The obtained results indicate that the BDDE with an optimized DPV method could be applied for the trace-level electroanalytical determination of SOL in human urine sample with excellent recovery and reproducibility.
PB  - Elsevier B.V.
T2  - Journal of Electroanalytical Chemistry
T1  - Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination
SP  - 118113
VL  - 957
DO  - 10.1016/j.jelechem.2024.118113
ER  - 
@article{
author = "Anojčić, Jasmina and Mijin, Dušan and Eraković Pantović, Sanja and Bogdanović, Aleksandra and Turuntaš, Nikola and Mutić, Sanja and Petrović, Slobodan and Avramov Ivić, Milka",
year = "2024-03",
abstract = "The anticholinergic drug, solifenacin, is frequently used for the treatment of the urological tract for urinary incontinence, and urinary frequency. The development of reliable and effective solifenacin electrochemical sensors is of great importance for the pharmaceutical industry and clinical practice. In this work, the electrochemical behavior of solifenacin succinate (SOL) was studied using three different working electrodes: gold (Au), glassy carbon (GCE) and boron-doped diamond electrode (BDDE). The cyclic voltammetric (CV) measurements performed in 0.05 M NaHCO3 indicated that the SOL oxidation process is irreversible and diffusion-controlled at all investigated working electrodes. Afterwards, the testing of SOL electrochemical stability and the possibility of its electrochemical degradation was performed at the Au electrode by the cycling of the potential during 3 h and continuously to 6 h. It was shown that the SOL was electrochemically transformed into another electroactive species and its degradation was excluded. For electroanalytical application, the anodically pretreated BDDE (+2.0 V; 30 s) was selected. Various experimental parameters were optimized, including the pH of the aqueous Britton-Robinson (B-R) buffer as a supporting electrolyte (from pH 2.0 to 11.98) and the most intensive peak of the target analyte was at pH 11.0, so this pH value was chosen as the optimum for further measurements. Based on the correlation of the SOL peak intensity and different concentrations, the developed differential pulse voltammetric (DPV) method was characterized by a linear concentration range from 0.041 to 2.50 µM, with a correlation coefficient of 0.999, and a relative standard deviation of 0.3 %. Taking into account the sensitivity of the developed DPV method towards the electrochemical oxidation of SOL, a very low detection limit of 0.012 µM in the model system was achieved. The BDDE showed adequate selectivity for SOL in the presence of the investigated interferents. The obtained results indicate that the BDDE with an optimized DPV method could be applied for the trace-level electroanalytical determination of SOL in human urine sample with excellent recovery and reproducibility.",
publisher = "Elsevier B.V.",
journal = "Journal of Electroanalytical Chemistry",
title = "Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination",
pages = "118113",
volume = "957",
doi = "10.1016/j.jelechem.2024.118113"
}
Anojčić, J., Mijin, D., Eraković Pantović, S., Bogdanović, A., Turuntaš, N., Mutić, S., Petrović, S.,& Avramov Ivić, M.. (2024-03). Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination. in Journal of Electroanalytical Chemistry
Elsevier B.V.., 957, 118113.
https://doi.org/10.1016/j.jelechem.2024.118113
Anojčić J, Mijin D, Eraković Pantović S, Bogdanović A, Turuntaš N, Mutić S, Petrović S, Avramov Ivić M. Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination. in Journal of Electroanalytical Chemistry. 2024;957:118113.
doi:10.1016/j.jelechem.2024.118113 .
Anojčić, Jasmina, Mijin, Dušan, Eraković Pantović, Sanja, Bogdanović, Aleksandra, Turuntaš, Nikola, Mutić, Sanja, Petrović, Slobodan, Avramov Ivić, Milka, "Voltammetric behavior of solifenacin succinate on gold, glassy carbon and boron-doped diamond electrodes: Stability testing and determination" in Journal of Electroanalytical Chemistry, 957 (2024-03):118113,
https://doi.org/10.1016/j.jelechem.2024.118113 . .

Sistem i postupak automatske klasifikacije UV/VIS signala radi dijagnostike bilijarne ciroze i njihova primena

Avramov-Ivić, Milka; Gavrovska, Ana; Vuković, Dragan; Mijin, Dušan; Petrović, Slobodan; Reljin, Branimir; Reljin, Irini; Milivojević, Milan; Stevanović, Sanja; Lović, Jelena

(Beograd : Savez pronalazača Beograda, 2023)


                                            

                                            
Avramov-Ivić, M., Gavrovska, A., Vuković, D., Mijin, D., Petrović, S., Reljin, B., Reljin, I., Milivojević, M., Stevanović, S.,& Lović, J.. (2023). Sistem i postupak automatske klasifikacije UV/VIS signala radi dijagnostike bilijarne ciroze i njihova primena. in Katalog / 37. Međunarodna izložba Pronalazaka, novih tehnologija i industrijskog dizajna „Pronalazaštvo-Beograd 2023.”, Beograd, 13-16.06.2023
Beograd : Savez pronalazača Beograda., 95-96.
https://hdl.handle.net/21.15107/rcub_technorep_6971
Avramov-Ivić M, Gavrovska A, Vuković D, Mijin D, Petrović S, Reljin B, Reljin I, Milivojević M, Stevanović S, Lović J. Sistem i postupak automatske klasifikacije UV/VIS signala radi dijagnostike bilijarne ciroze i njihova primena. in Katalog / 37. Međunarodna izložba Pronalazaka, novih tehnologija i industrijskog dizajna „Pronalazaštvo-Beograd 2023.”, Beograd, 13-16.06.2023. 2023;:95-96.
https://hdl.handle.net/21.15107/rcub_technorep_6971 .
Avramov-Ivić, Milka, Gavrovska, Ana, Vuković, Dragan, Mijin, Dušan, Petrović, Slobodan, Reljin, Branimir, Reljin, Irini, Milivojević, Milan, Stevanović, Sanja, Lović, Jelena, "Sistem i postupak automatske klasifikacije UV/VIS signala radi dijagnostike bilijarne ciroze i njihova primena" in Katalog / 37. Međunarodna izložba Pronalazaka, novih tehnologija i industrijskog dizajna „Pronalazaštvo-Beograd 2023.”, Beograd, 13-16.06.2023 (2023):95-96,
https://hdl.handle.net/21.15107/rcub_technorep_6971 .

Computer–aided decision–assistant system for diagnosis of different diseases

Avramov Ivić, Milka; Petrović, Slobodan D.; Reljin, Branimir; Reljin, Irini; Mijin, Dušan; Stevanović, Sanja; Lović, Jelena; Vuković, Dragan

(Beograd : Udruženje inženjera Srbije za koroziju i zaštitu materijala UISKOZAM, 2019)

TY  - CONF
AU  - Avramov Ivić, Milka
AU  - Petrović, Slobodan D.
AU  - Reljin, Branimir
AU  - Reljin, Irini
AU  - Mijin, Dušan
AU  - Stevanović, Sanja
AU  - Lović, Jelena
AU  - Vuković, Dragan
PY  - 2019
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7304
AB  - The constant need to find an increasing number of diagnostic more selective techniques by which we would be able to determine an altered substrate as characteristic of the disease suspected is everyday clinical problem. It is important to note that diagnostic failure is the main cause of unnecessary costs that account for about 35% funds intended for healing in funds. The greatest number of people will experience at least one diagnostic error during their lifetime. The already realized results concerning new invented UV-vis method and automatic classification of the obtained spectroscopic signals in diagnostics of different diseases led to the the invention and construction of Computer-Aided Decision-Assistant system for Diagnosis of Different Diseases. It was achieved by automatization of UV-vis signals of different body fluids without or with known official diagnosis. In the invention and construction of this system is included clinical work, the softwer and hardwer realization, design and logo. Results included into the realization of constructed prototype will be presented.
PB  - Beograd : Udruženje inženjera Srbije za koroziju i zaštitu materijala UISKOZAM
C3  - Stecište nauke i prakse u oblastima korozije, zaštite materijala i životne sredine Elektronski izvor : knjiga radova / XXI YuCorr Jugoslovenska korozija Međunarodna konferencija = Meeting point of the science and practice in the fields of corrosion, materials and environmental protection : proceedings / XXI YuCorr International Conference, September 17-20, 2019, Tara Mountain, Serbia
T1  - Computer–aided decision–assistant system for diagnosis of different diseases
T1  - Računarski zasnovan sistem za asistenciju pri dijagnostici različitih oboljenja
SP  - 2
UR  - https://hdl.handle.net/21.15107/rcub_technorep_7304
ER  - 
@conference{
author = "Avramov Ivić, Milka and Petrović, Slobodan D. and Reljin, Branimir and Reljin, Irini and Mijin, Dušan and Stevanović, Sanja and Lović, Jelena and Vuković, Dragan",
year = "2019",
abstract = "The constant need to find an increasing number of diagnostic more selective techniques by which we would be able to determine an altered substrate as characteristic of the disease suspected is everyday clinical problem. It is important to note that diagnostic failure is the main cause of unnecessary costs that account for about 35% funds intended for healing in funds. The greatest number of people will experience at least one diagnostic error during their lifetime. The already realized results concerning new invented UV-vis method and automatic classification of the obtained spectroscopic signals in diagnostics of different diseases led to the the invention and construction of Computer-Aided Decision-Assistant system for Diagnosis of Different Diseases. It was achieved by automatization of UV-vis signals of different body fluids without or with known official diagnosis. In the invention and construction of this system is included clinical work, the softwer and hardwer realization, design and logo. Results included into the realization of constructed prototype will be presented.",
publisher = "Beograd : Udruženje inženjera Srbije za koroziju i zaštitu materijala UISKOZAM",
journal = "Stecište nauke i prakse u oblastima korozije, zaštite materijala i životne sredine Elektronski izvor : knjiga radova / XXI YuCorr Jugoslovenska korozija Međunarodna konferencija = Meeting point of the science and practice in the fields of corrosion, materials and environmental protection : proceedings / XXI YuCorr International Conference, September 17-20, 2019, Tara Mountain, Serbia",
title = "Computer–aided decision–assistant system for diagnosis of different diseases, Računarski zasnovan sistem za asistenciju pri dijagnostici različitih oboljenja",
pages = "2",
url = "https://hdl.handle.net/21.15107/rcub_technorep_7304"
}
Avramov Ivić, M., Petrović, S. D., Reljin, B., Reljin, I., Mijin, D., Stevanović, S., Lović, J.,& Vuković, D.. (2019). Computer–aided decision–assistant system for diagnosis of different diseases. in Stecište nauke i prakse u oblastima korozije, zaštite materijala i životne sredine Elektronski izvor : knjiga radova / XXI YuCorr Jugoslovenska korozija Međunarodna konferencija = Meeting point of the science and practice in the fields of corrosion, materials and environmental protection : proceedings / XXI YuCorr International Conference, September 17-20, 2019, Tara Mountain, Serbia
Beograd : Udruženje inženjera Srbije za koroziju i zaštitu materijala UISKOZAM., 2.
https://hdl.handle.net/21.15107/rcub_technorep_7304
Avramov Ivić M, Petrović SD, Reljin B, Reljin I, Mijin D, Stevanović S, Lović J, Vuković D. Computer–aided decision–assistant system for diagnosis of different diseases. in Stecište nauke i prakse u oblastima korozije, zaštite materijala i životne sredine Elektronski izvor : knjiga radova / XXI YuCorr Jugoslovenska korozija Međunarodna konferencija = Meeting point of the science and practice in the fields of corrosion, materials and environmental protection : proceedings / XXI YuCorr International Conference, September 17-20, 2019, Tara Mountain, Serbia. 2019;:2.
https://hdl.handle.net/21.15107/rcub_technorep_7304 .
Avramov Ivić, Milka, Petrović, Slobodan D., Reljin, Branimir, Reljin, Irini, Mijin, Dušan, Stevanović, Sanja, Lović, Jelena, Vuković, Dragan, "Computer–aided decision–assistant system for diagnosis of different diseases" in Stecište nauke i prakse u oblastima korozije, zaštite materijala i životne sredine Elektronski izvor : knjiga radova / XXI YuCorr Jugoslovenska korozija Međunarodna konferencija = Meeting point of the science and practice in the fields of corrosion, materials and environmental protection : proceedings / XXI YuCorr International Conference, September 17-20, 2019, Tara Mountain, Serbia (2019):2,
https://hdl.handle.net/21.15107/rcub_technorep_7304 .