An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis

Baljozović, Andreja; Glišić, Dragomir; Radović, Nenad; Radovanović, Željko; Baščarević, Zoran

(Elsevier Inc., 2023)

TY  - JOUR
AU  - Baljozović, Andreja
AU  - Glišić, Dragomir
AU  - Radović, Nenad
AU  - Radovanović, Željko
AU  - Baščarević, Zoran
PY  - 2023
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/6592
AB  - The cementless Corail stem is one of the most frequently implanted stems and has undergone several design changes. Currently in use is the third generation, named Corail AMT. Until now, only one third-generation Corail stem neck fracture has been described in 2020. In our paper, we present an almost identical complication with an additional analysis of the fracture using a scanning electron microscope. The revision surgery consisted of changing the broken implant with a Corail revision stem, along with replacing the polyethylene liner and the femoral head with new one, after which the patient achieved a full recovery. According to the available literature, this is the second case of this extremely rare complication.
PB  - Elsevier Inc.
T2  - Arthroplasty Today
T1  - An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis
SP  - 101176
VL  - 22
DO  - 10.1016/j.artd.2023.101176
ER  - 
@article{
author = "Baljozović, Andreja and Glišić, Dragomir and Radović, Nenad and Radovanović, Željko and Baščarević, Zoran",
year = "2023",
abstract = "The cementless Corail stem is one of the most frequently implanted stems and has undergone several design changes. Currently in use is the third generation, named Corail AMT. Until now, only one third-generation Corail stem neck fracture has been described in 2020. In our paper, we present an almost identical complication with an additional analysis of the fracture using a scanning electron microscope. The revision surgery consisted of changing the broken implant with a Corail revision stem, along with replacing the polyethylene liner and the femoral head with new one, after which the patient achieved a full recovery. According to the available literature, this is the second case of this extremely rare complication.",
publisher = "Elsevier Inc.",
journal = "Arthroplasty Today",
title = "An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis",
pages = "101176",
volume = "22",
doi = "10.1016/j.artd.2023.101176"
}
Baljozović, A., Glišić, D., Radović, N., Radovanović, Ž.,& Baščarević, Z.. (2023). An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis. in Arthroplasty Today
Elsevier Inc.., 22, 101176.
https://doi.org/10.1016/j.artd.2023.101176
Baljozović A, Glišić D, Radović N, Radovanović Ž, Baščarević Z. An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis. in Arthroplasty Today. 2023;22:101176.
doi:10.1016/j.artd.2023.101176 .
Baljozović, Andreja, Glišić, Dragomir, Radović, Nenad, Radovanović, Željko, Baščarević, Zoran, "An Extremely Rare Case of Cementless Third Generation Corail Stem Neck Fracture With Fractographic Analysis" in Arthroplasty Today, 22 (2023):101176,