Miletić, Maja

Link to this page

Authority KeyName Variants
orcid::0000-0002-8622-7171
  • Miletić, Maja (3)

Author's Bibliography

Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients

Đukić, Tamara; Drvenica, Ivana; Kovačić, Marijana; Milanović, Slađan; Majerič, Dragana; Šefik-Bukilica, Mirjana; Miletić, Maja; Bugarski, Branko; Ilić, Vesna

(MDPI, 2024)

TY  - JOUR
AU  - Đukić, Tamara
AU  - Drvenica, Ivana
AU  - Kovačić, Marijana
AU  - Milanović, Slađan
AU  - Majerič, Dragana
AU  - Šefik-Bukilica, Mirjana
AU  - Miletić, Maja
AU  - Bugarski, Branko
AU  - Ilić, Vesna
PY  - 2024
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7411
AB  - The function of immune complexes in rheumatoid arthritis (RA) is related to their composition and size. Using dynamic light scattering (DLS), we investigated the link between the RA circulating immune complex (CIC) particles’ size and the CIC immunoglobulin level. In this study, 30 RA patients and 30 healthy individuals were included. IgA, IgG, and IgM were found in all analyzed CICs, but more IgA and IgG were found in RA than in control CICs. In both control and RA CICs, DLS detected 50 particles that differed in size and clustered around two size groups: with a 7.5–164 nm radius and with a 342–1718 nm radius. An increased level of IgA in RA CICs, compared to control ones, was associated with more than 50% of CIC particles. In RA, compared to the control, a higher number of CICs with 28.2 nm, 531 nm, 712 nm, and 1718 nm particles and a lower number of CICs with 78.8 nm particles were detected. This particle distribution pattern did not reflect the changes in the CIC immunoglobulin level. Thus, RA elevated CIC IgA was linked with all these particles (except the 1718 nm particle), the IgM increase was linked with 43.8 nm and 712 nm particles, and the IgG increase was linked with the 712 nm particle only. This study provides the very first data on the association between CIC particles’ size, CIC immunoglobulin level, and RA. It opens the possibility that the size of CICs determined by DLS can be used as a criterion in RA diagnosis or monitoring after a large-scale study confirmation.
PB  - MDPI
T2  - International Journal of Molecular Sciences
T1  - Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients
IS  - 6
SP  - 3138
VL  - 25
DO  - 10.3390/ijms25063138
ER  - 
@article{
author = "Đukić, Tamara and Drvenica, Ivana and Kovačić, Marijana and Milanović, Slađan and Majerič, Dragana and Šefik-Bukilica, Mirjana and Miletić, Maja and Bugarski, Branko and Ilić, Vesna",
year = "2024",
abstract = "The function of immune complexes in rheumatoid arthritis (RA) is related to their composition and size. Using dynamic light scattering (DLS), we investigated the link between the RA circulating immune complex (CIC) particles’ size and the CIC immunoglobulin level. In this study, 30 RA patients and 30 healthy individuals were included. IgA, IgG, and IgM were found in all analyzed CICs, but more IgA and IgG were found in RA than in control CICs. In both control and RA CICs, DLS detected 50 particles that differed in size and clustered around two size groups: with a 7.5–164 nm radius and with a 342–1718 nm radius. An increased level of IgA in RA CICs, compared to control ones, was associated with more than 50% of CIC particles. In RA, compared to the control, a higher number of CICs with 28.2 nm, 531 nm, 712 nm, and 1718 nm particles and a lower number of CICs with 78.8 nm particles were detected. This particle distribution pattern did not reflect the changes in the CIC immunoglobulin level. Thus, RA elevated CIC IgA was linked with all these particles (except the 1718 nm particle), the IgM increase was linked with 43.8 nm and 712 nm particles, and the IgG increase was linked with the 712 nm particle only. This study provides the very first data on the association between CIC particles’ size, CIC immunoglobulin level, and RA. It opens the possibility that the size of CICs determined by DLS can be used as a criterion in RA diagnosis or monitoring after a large-scale study confirmation.",
publisher = "MDPI",
journal = "International Journal of Molecular Sciences",
title = "Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients",
number = "6",
pages = "3138",
volume = "25",
doi = "10.3390/ijms25063138"
}
Đukić, T., Drvenica, I., Kovačić, M., Milanović, S., Majerič, D., Šefik-Bukilica, M., Miletić, M., Bugarski, B.,& Ilić, V.. (2024). Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients. in International Journal of Molecular Sciences
MDPI., 25(6), 3138.
https://doi.org/10.3390/ijms25063138
Đukić T, Drvenica I, Kovačić M, Milanović S, Majerič D, Šefik-Bukilica M, Miletić M, Bugarski B, Ilić V. Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients. in International Journal of Molecular Sciences. 2024;25(6):3138.
doi:10.3390/ijms25063138 .
Đukić, Tamara, Drvenica, Ivana, Kovačić, Marijana, Milanović, Slađan, Majerič, Dragana, Šefik-Bukilica, Mirjana, Miletić, Maja, Bugarski, Branko, Ilić, Vesna, "Exploring the Link between Hydrodynamic Size and Immunoglobulins of Circulating Immune Complexes in Rheumatoid Arthritis Patients" in International Journal of Molecular Sciences, 25, no. 6 (2024):3138,
https://doi.org/10.3390/ijms25063138 . .

Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives

Stasić, Jovana; Selaković, Nenad; Puač, Nevena; Miletić, Maja; Malović, Gordana; Petrović, Zoran Lj; Veljović, Đorđe; Miletić, Vesna

(Springer Verlag, 2019)

TY  - JOUR
AU  - Stasić, Jovana
AU  - Selaković, Nenad
AU  - Puač, Nevena
AU  - Miletić, Maja
AU  - Malović, Gordana
AU  - Petrović, Zoran Lj
AU  - Veljović, Đorđe
AU  - Miletić, Vesna
PY  - 2019
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5048
AB  - The study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives. Materials and methods: Mid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O 2 , He + 1.5% O 2 ), power input (1 or 3 W), and tip-to-surface distance (2, 4, or 8 mm). Contact angles of reference liquids and SFE of dentin following He + 1.5% O 2 at 3-W and 4-mm treatment was compared to phosphoric acid etching. Contact angles of Single Bond Universal (SBU; 3M ESPE) and Clearfil Universal Bond (CUB; Kuraray Noritake) were measured following NTAP, etch-and-rinse, and self-etch protocols. Results: NTAP significantly reduced contact angles of reference liquids and increased dentin SFE compared to untreated dentin (p < 0.05). O 2 intensified the effect of He NTAP (p < 0.05). NTAP and phosphoric acid increased dentin polarity and Lewis base surface characteristics. Phosphoric acid increased contact angles of adhesives compared to the self-etch protocol (p < 0.05). NTAP resulted in lower adhesive contact angles than phosphoric acid, the difference being statistically significant for CUB (p [removed] 0.05). Conclusions: He NTAP with and without O 2 increased dentin wetting and SFE, surpassing the effect of phosphoric acid and lowering adhesive contact angles. NTAP produced no apparent micro-morphological changes on dentin surface comparable to acid etching. Clinical significance: NTAP treatment of dentin prior to adhesive application increases dentin wetting and surface free energy facilitating better adhesive distribution on dentin surface compared to phosphoric acid etching and similar to the “self-etch” application protocol.
PB  - Springer Verlag
T2  - Clinical Oral Investigations
T1  - Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives
EP  - 1396
IS  - 3
SP  - 1383
VL  - 23
DO  - 10.1007/s00784-018-2563-2
ER  - 
@article{
author = "Stasić, Jovana and Selaković, Nenad and Puač, Nevena and Miletić, Maja and Malović, Gordana and Petrović, Zoran Lj and Veljović, Đorđe and Miletić, Vesna",
year = "2019",
abstract = "The study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives. Materials and methods: Mid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O 2 , He + 1.5% O 2 ), power input (1 or 3 W), and tip-to-surface distance (2, 4, or 8 mm). Contact angles of reference liquids and SFE of dentin following He + 1.5% O 2 at 3-W and 4-mm treatment was compared to phosphoric acid etching. Contact angles of Single Bond Universal (SBU; 3M ESPE) and Clearfil Universal Bond (CUB; Kuraray Noritake) were measured following NTAP, etch-and-rinse, and self-etch protocols. Results: NTAP significantly reduced contact angles of reference liquids and increased dentin SFE compared to untreated dentin (p < 0.05). O 2 intensified the effect of He NTAP (p < 0.05). NTAP and phosphoric acid increased dentin polarity and Lewis base surface characteristics. Phosphoric acid increased contact angles of adhesives compared to the self-etch protocol (p < 0.05). NTAP resulted in lower adhesive contact angles than phosphoric acid, the difference being statistically significant for CUB (p [removed] 0.05). Conclusions: He NTAP with and without O 2 increased dentin wetting and SFE, surpassing the effect of phosphoric acid and lowering adhesive contact angles. NTAP produced no apparent micro-morphological changes on dentin surface comparable to acid etching. Clinical significance: NTAP treatment of dentin prior to adhesive application increases dentin wetting and surface free energy facilitating better adhesive distribution on dentin surface compared to phosphoric acid etching and similar to the “self-etch” application protocol.",
publisher = "Springer Verlag",
journal = "Clinical Oral Investigations",
title = "Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives",
pages = "1396-1383",
number = "3",
volume = "23",
doi = "10.1007/s00784-018-2563-2"
}
Stasić, J., Selaković, N., Puač, N., Miletić, M., Malović, G., Petrović, Z. L., Veljović, Đ.,& Miletić, V.. (2019). Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives. in Clinical Oral Investigations
Springer Verlag., 23(3), 1383-1396.
https://doi.org/10.1007/s00784-018-2563-2
Stasić J, Selaković N, Puač N, Miletić M, Malović G, Petrović ZL, Veljović Đ, Miletić V. Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives. in Clinical Oral Investigations. 2019;23(3):1383-1396.
doi:10.1007/s00784-018-2563-2 .
Stasić, Jovana, Selaković, Nenad, Puač, Nevena, Miletić, Maja, Malović, Gordana, Petrović, Zoran Lj, Veljović, Đorđe, Miletić, Vesna, "Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives" in Clinical Oral Investigations, 23, no. 3 (2019):1383-1396,
https://doi.org/10.1007/s00784-018-2563-2 . .
20
12
18

Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives

Stasić, Jovana; Selaković, Nenad; Puač, Nevena; Miletić, Maja; Malović, Gordana; Petrović, Zoran Lj; Veljović, Đorđe; Miletić, Vesna

(Springer Heidelberg, Heidelberg, 2019)

TY  - JOUR
AU  - Stasić, Jovana
AU  - Selaković, Nenad
AU  - Puač, Nevena
AU  - Miletić, Maja
AU  - Malović, Gordana
AU  - Petrović, Zoran Lj
AU  - Veljović, Đorđe
AU  - Miletić, Vesna
PY  - 2019
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4263
AB  - ObjectivesThe study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives.Materials and methodsMid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O-2, He + 1.5% O-2), power input (1 or 3W), and tip-to-surface distance (2, 4, or 8mm). Contact angles of reference liquids and SFE of dentin following He + 1.5% O-2 at 3-W and 4-mm treatment was compared to phosphoric acid etching. Contact angles of Single Bond Universal (SBU; 3M ESPE) and Clearfil Universal Bond (CUB; Kuraray Noritake) were measured following NTAP, etch-and-rinse, and self-etch protocols.ResultsNTAP significantly reduced contact angles of reference liquids and increased dentin SFE compared to untreated dentin (p lt 0.05). O-2 intensified the effect of He NTAP (p lt 0.05). NTAP and phosphoric acid increased dentin polarity and Lewis base surface characteristics. Phosphoric acid increased contact angles of adhesives compared to the self-etch protocol (p lt 0.05). NTAP resulted in lower adhesive contact angles than phosphoric acid, the difference being statistically significant for CUB (p lt 0.05). Compared to the self-etch protocol, NTAP slightly reduced CUB contact angle but not that of SBU (p gt 0.05).ConclusionsHe NTAP with and without O-2 increased dentin wetting and SFE, surpassing the effect of phosphoric acid and lowering adhesive contact angles. NTAP produced no apparent micro-morphological changes on dentin surface comparable to acid etching.Clinical significanceNTAP treatment of dentin prior to adhesive application increases dentin wetting and surface free energy facilitating better adhesive distribution on dentin surface compared to phosphoric acid etching and similar to the self-etch application protocol.
PB  - Springer Heidelberg, Heidelberg
T2  - Clinical Oral Investigations
T1  - Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives
EP  - 1396
IS  - 3
SP  - 1383
VL  - 23
DO  - 10.1007/s00784-018-2563-2
ER  - 
@article{
author = "Stasić, Jovana and Selaković, Nenad and Puač, Nevena and Miletić, Maja and Malović, Gordana and Petrović, Zoran Lj and Veljović, Đorđe and Miletić, Vesna",
year = "2019",
abstract = "ObjectivesThe study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives.Materials and methodsMid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O-2, He + 1.5% O-2), power input (1 or 3W), and tip-to-surface distance (2, 4, or 8mm). Contact angles of reference liquids and SFE of dentin following He + 1.5% O-2 at 3-W and 4-mm treatment was compared to phosphoric acid etching. Contact angles of Single Bond Universal (SBU; 3M ESPE) and Clearfil Universal Bond (CUB; Kuraray Noritake) were measured following NTAP, etch-and-rinse, and self-etch protocols.ResultsNTAP significantly reduced contact angles of reference liquids and increased dentin SFE compared to untreated dentin (p lt 0.05). O-2 intensified the effect of He NTAP (p lt 0.05). NTAP and phosphoric acid increased dentin polarity and Lewis base surface characteristics. Phosphoric acid increased contact angles of adhesives compared to the self-etch protocol (p lt 0.05). NTAP resulted in lower adhesive contact angles than phosphoric acid, the difference being statistically significant for CUB (p lt 0.05). Compared to the self-etch protocol, NTAP slightly reduced CUB contact angle but not that of SBU (p gt 0.05).ConclusionsHe NTAP with and without O-2 increased dentin wetting and SFE, surpassing the effect of phosphoric acid and lowering adhesive contact angles. NTAP produced no apparent micro-morphological changes on dentin surface comparable to acid etching.Clinical significanceNTAP treatment of dentin prior to adhesive application increases dentin wetting and surface free energy facilitating better adhesive distribution on dentin surface compared to phosphoric acid etching and similar to the self-etch application protocol.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Clinical Oral Investigations",
title = "Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives",
pages = "1396-1383",
number = "3",
volume = "23",
doi = "10.1007/s00784-018-2563-2"
}
Stasić, J., Selaković, N., Puač, N., Miletić, M., Malović, G., Petrović, Z. L., Veljović, Đ.,& Miletić, V.. (2019). Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives. in Clinical Oral Investigations
Springer Heidelberg, Heidelberg., 23(3), 1383-1396.
https://doi.org/10.1007/s00784-018-2563-2
Stasić J, Selaković N, Puač N, Miletić M, Malović G, Petrović ZL, Veljović Đ, Miletić V. Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives. in Clinical Oral Investigations. 2019;23(3):1383-1396.
doi:10.1007/s00784-018-2563-2 .
Stasić, Jovana, Selaković, Nenad, Puač, Nevena, Miletić, Maja, Malović, Gordana, Petrović, Zoran Lj, Veljović, Đorđe, Miletić, Vesna, "Effects of non-thermal atmospheric plasma treatment on dentin wetting and surface free energy for application of universal adhesives" in Clinical Oral Investigations, 23, no. 3 (2019):1383-1396,
https://doi.org/10.1007/s00784-018-2563-2 . .
20
12
18