The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions

Karkalić, Radovan; Jovanović, Dalibor B.; Radaković, Sonja S.; Rajić, Dušan; Petrović, Biljana V.; Ivanković, Negovan; Senić, Željko

(Association of Chemical Engineers of Serbia, 2015)

TY  - JOUR
AU  - Karkalić, Radovan
AU  - Jovanović, Dalibor B.
AU  - Radaković, Sonja S.
AU  - Rajić, Dušan
AU  - Petrović, Biljana V.
AU  - Ivanković, Negovan
AU  - Senić, Željko
PY  - 2015
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888
AB  - The present study was conducted in order to evaluate efficiency of a personal body cooling system based on passive evaporative technologies and its effects on test subjects and their psycho-physiological suitability during exertional heat stress in hot environment. Performed results are based on conducted tests in climatic chamber in the Military Medical Academy Institute of Hygiene in Belgrade. Ten male test subjects were subjected to exertional heat stress test consisted of walking on motorized treadmill at a speed of 5 km/h in hot environment. Tests were performed with and without cooling system. As a physiological strain indicator the following parameters have been determined: mean skin temperature, tympanic temperature, heart rate and sweat rate. Results confirmed that cooling vest worn over the clothes was able to attenuate the physiological strain levels during exercise, when compared to identical exposure without the cooling system.
AB  - Rad predstavlja rezultate naučnih istraživanja na polju efikasnosti sistema za hlađenje tela iz grupe pasivnih sistema na bazi isparavanja i njegov uticaj na fiziološku podobnost ljudi u uslovima izloženosti fizičkom naporu i ekstremno visokim temperaturama. Podaci i dobijeni rezultati zasnovani su na ispitivanjima sprovedenim u klimatskoj komori Instituta za higijenu VMA u Beogradu. Deset ispitanika muškog pola dobrovoljno je podvrgnuto testovima toplotnog opterećenja usled fizičkog napora, izazvanog hodanjem na pokretnoj traci sa brzinom hoda od 5 km/h, u toploj sredini (temperatura vazduha 40 °C). Testovi su realizovani sa ispitanicima srednjih godina (27.2±2.6), sličnih antropometrijskih parametara (74±7 kg, 184±9 cm), u varijanti nošenja radne odeće bez ikakvog rashladnog sistema (opcija NoCOOL) i uz upotrebu rashladnih prsluka za hlađenje tela, model Arctic Heat® (opcija ACOOL). Kao pokazatelji fiziološkog opterećenja određivane su: srednja temperatura kože (Tsk), timpanična temperatura (Tty) i frekvencija srčanog rada (HR), dok je intenzitet znojenja (SwR) izračunat kao pokazatelj vodeno-elektrolitskog statusa. U svim slučajevima izlaganje fizičkom naporu u toploj sredini indukovalo je fiziološki odgovor, manifestovan kroz povećanje timpanične temperature, frekvencije srčanog rada i intenziteta znojenja. U varijantama primene rashladnog prsluka (COOL), timpanična temperatura i srednja temperatura kože su imale značajno niže vrednosti (p  lt  0,05), kao i intenzitet znojenja (p  lt  0,001). Eksperimentalni rezultati dokazali su uticaj rashladnog prsluka, korišćenog preko radne odeće, na snižavanje nivoa fiziološkog opterećenja tokom izlaganja korisnika ekstremnim uslovima, u poređenju sa identičnim testovima u varijanti bez hlađenja tela.
PB  - Association of Chemical Engineers of Serbia
T2  - Hemijska industrija
T1  - The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
T1  - Uticaj prsluka za hlađenje sa sistemom pasivnog isparavanja na nivo fiziološkog opterećenja radnika hemijske industrije u toploj sredini
EP  - 594
IS  - 6
SP  - 587
VL  - 69
DO  - 10.2298/HEMIND140705079K
ER  - 
@article{
author = "Karkalić, Radovan and Jovanović, Dalibor B. and Radaković, Sonja S. and Rajić, Dušan and Petrović, Biljana V. and Ivanković, Negovan and Senić, Željko",
year = "2015",
abstract = "The present study was conducted in order to evaluate efficiency of a personal body cooling system based on passive evaporative technologies and its effects on test subjects and their psycho-physiological suitability during exertional heat stress in hot environment. Performed results are based on conducted tests in climatic chamber in the Military Medical Academy Institute of Hygiene in Belgrade. Ten male test subjects were subjected to exertional heat stress test consisted of walking on motorized treadmill at a speed of 5 km/h in hot environment. Tests were performed with and without cooling system. As a physiological strain indicator the following parameters have been determined: mean skin temperature, tympanic temperature, heart rate and sweat rate. Results confirmed that cooling vest worn over the clothes was able to attenuate the physiological strain levels during exercise, when compared to identical exposure without the cooling system., Rad predstavlja rezultate naučnih istraživanja na polju efikasnosti sistema za hlađenje tela iz grupe pasivnih sistema na bazi isparavanja i njegov uticaj na fiziološku podobnost ljudi u uslovima izloženosti fizičkom naporu i ekstremno visokim temperaturama. Podaci i dobijeni rezultati zasnovani su na ispitivanjima sprovedenim u klimatskoj komori Instituta za higijenu VMA u Beogradu. Deset ispitanika muškog pola dobrovoljno je podvrgnuto testovima toplotnog opterećenja usled fizičkog napora, izazvanog hodanjem na pokretnoj traci sa brzinom hoda od 5 km/h, u toploj sredini (temperatura vazduha 40 °C). Testovi su realizovani sa ispitanicima srednjih godina (27.2±2.6), sličnih antropometrijskih parametara (74±7 kg, 184±9 cm), u varijanti nošenja radne odeće bez ikakvog rashladnog sistema (opcija NoCOOL) i uz upotrebu rashladnih prsluka za hlađenje tela, model Arctic Heat® (opcija ACOOL). Kao pokazatelji fiziološkog opterećenja određivane su: srednja temperatura kože (Tsk), timpanična temperatura (Tty) i frekvencija srčanog rada (HR), dok je intenzitet znojenja (SwR) izračunat kao pokazatelj vodeno-elektrolitskog statusa. U svim slučajevima izlaganje fizičkom naporu u toploj sredini indukovalo je fiziološki odgovor, manifestovan kroz povećanje timpanične temperature, frekvencije srčanog rada i intenziteta znojenja. U varijantama primene rashladnog prsluka (COOL), timpanična temperatura i srednja temperatura kože su imale značajno niže vrednosti (p  lt  0,05), kao i intenzitet znojenja (p  lt  0,001). Eksperimentalni rezultati dokazali su uticaj rashladnog prsluka, korišćenog preko radne odeće, na snižavanje nivoa fiziološkog opterećenja tokom izlaganja korisnika ekstremnim uslovima, u poređenju sa identičnim testovima u varijanti bez hlađenja tela.",
publisher = "Association of Chemical Engineers of Serbia",
journal = "Hemijska industrija",
title = "The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions, Uticaj prsluka za hlađenje sa sistemom pasivnog isparavanja na nivo fiziološkog opterećenja radnika hemijske industrije u toploj sredini",
pages = "594-587",
number = "6",
volume = "69",
doi = "10.2298/HEMIND140705079K"
}
Karkalić, R., Jovanović, D. B., Radaković, S. S., Rajić, D., Petrović, B. V., Ivanković, N.,& Senić, Ž.. (2015). The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions. in Hemijska industrija
Association of Chemical Engineers of Serbia., 69(6), 587-594.
https://doi.org/10.2298/HEMIND140705079K
Karkalić R, Jovanović DB, Radaković SS, Rajić D, Petrović BV, Ivanković N, Senić Ž. The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions. in Hemijska industrija. 2015;69(6):587-594.
doi:10.2298/HEMIND140705079K .
Karkalić, Radovan, Jovanović, Dalibor B., Radaković, Sonja S., Rajić, Dušan, Petrović, Biljana V., Ivanković, Negovan, Senić, Željko, "The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions" in Hemijska industrija, 69, no. 6 (2015):587-594,
https://doi.org/10.2298/HEMIND140705079K . .
3
6
2
5