Ivanović, Vera

Link to this page

Authority KeyName Variants
0bd26b5b-84bd-466f-961b-88cbb9c7946d
  • Ivanović, Vera (1)
Projects

Author's Bibliography

Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes

Radunović, Milena; Pavić, Aleksandar; Ivanović, Vera; Milivojević, Marija; Radović, Igor; Di Carlo, Roberta; Pilato, Serena; Fontana, Antonella; Piattelli, Adriano; Petrović, Sanja

(Elsevier Inc., 2022)

TY  - JOUR
AU  - Radunović, Milena
AU  - Pavić, Aleksandar
AU  - Ivanović, Vera
AU  - Milivojević, Marija
AU  - Radović, Igor
AU  - Di Carlo, Roberta
AU  - Pilato, Serena
AU  - Fontana, Antonella
AU  - Piattelli, Adriano
AU  - Petrović, Sanja
PY  - 2022
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5144
AB  - The aims of the study were: 1) to evaluate the effect on biofilm formation of barrier membranes and titanium surfaces coated with graphene-oxide (GO); 2) to analyze the connection between the superficial topography of the tested materials and the amount of bacterial accumulation on them and 3) to analyze the biocompatibility of GO functionalized discs using the zebrafish model. Methods: Single species bacterial biofilms (Streptococcus oralis, Veilonella parvula, Fusobacterium nucleatum, Porphyomonas gingivalis) were grown on GO-free membranes, membranes coated with 2 and 10 μg/ml of GO, GO-free and GO-coated titanium discs. The biofilms were analyzed by determining the CFU count and by Scanning Electron Microscopy (SEM) and the materials’ topography by Atomic Force Microscopy (AFM). Zebrafish model was used to determine the materials’ toxicity and inflammatory effects. Results: AFM showed similar roughness of control and GO-coated materials. CFU counts on GO-coated discs were significantly lower than on control discs for all species. CFU counts of S. oralis, V. parvula and P. gingivalis were lower on biofilms grown on both types of GO-coated membranes than on GO-free membrane. SEM analysis showed different formation of single species biofilm of S. oralis on control and GO-coated materials. GO-functionalized titanium discs do not induce toxic or inflammatory effects. Significance: Titanium implant surfaces functionalized with GO have shown to be biocompatible and less susceptible to biofilm formation. These results encourage further in vivo investigation of the tested materials on infection prevention, specifically in prevention and reduction of peri-implant mucositis and periimplantitis incidence.
PB  - Elsevier Inc.
T2  - Dental Materials
T1  - Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes
EP  - 1127
IS  - 7
SP  - 1117
VL  - 38
DO  - 10.1016/j.dental.2022.04.024
ER  - 
@article{
author = "Radunović, Milena and Pavić, Aleksandar and Ivanović, Vera and Milivojević, Marija and Radović, Igor and Di Carlo, Roberta and Pilato, Serena and Fontana, Antonella and Piattelli, Adriano and Petrović, Sanja",
year = "2022",
abstract = "The aims of the study were: 1) to evaluate the effect on biofilm formation of barrier membranes and titanium surfaces coated with graphene-oxide (GO); 2) to analyze the connection between the superficial topography of the tested materials and the amount of bacterial accumulation on them and 3) to analyze the biocompatibility of GO functionalized discs using the zebrafish model. Methods: Single species bacterial biofilms (Streptococcus oralis, Veilonella parvula, Fusobacterium nucleatum, Porphyomonas gingivalis) were grown on GO-free membranes, membranes coated with 2 and 10 μg/ml of GO, GO-free and GO-coated titanium discs. The biofilms were analyzed by determining the CFU count and by Scanning Electron Microscopy (SEM) and the materials’ topography by Atomic Force Microscopy (AFM). Zebrafish model was used to determine the materials’ toxicity and inflammatory effects. Results: AFM showed similar roughness of control and GO-coated materials. CFU counts on GO-coated discs were significantly lower than on control discs for all species. CFU counts of S. oralis, V. parvula and P. gingivalis were lower on biofilms grown on both types of GO-coated membranes than on GO-free membrane. SEM analysis showed different formation of single species biofilm of S. oralis on control and GO-coated materials. GO-functionalized titanium discs do not induce toxic or inflammatory effects. Significance: Titanium implant surfaces functionalized with GO have shown to be biocompatible and less susceptible to biofilm formation. These results encourage further in vivo investigation of the tested materials on infection prevention, specifically in prevention and reduction of peri-implant mucositis and periimplantitis incidence.",
publisher = "Elsevier Inc.",
journal = "Dental Materials",
title = "Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes",
pages = "1127-1117",
number = "7",
volume = "38",
doi = "10.1016/j.dental.2022.04.024"
}
Radunović, M., Pavić, A., Ivanović, V., Milivojević, M., Radović, I., Di Carlo, R., Pilato, S., Fontana, A., Piattelli, A.,& Petrović, S.. (2022). Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes. in Dental Materials
Elsevier Inc.., 38(7), 1117-1127.
https://doi.org/10.1016/j.dental.2022.04.024
Radunović M, Pavić A, Ivanović V, Milivojević M, Radović I, Di Carlo R, Pilato S, Fontana A, Piattelli A, Petrović S. Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes. in Dental Materials. 2022;38(7):1117-1127.
doi:10.1016/j.dental.2022.04.024 .
Radunović, Milena, Pavić, Aleksandar, Ivanović, Vera, Milivojević, Marija, Radović, Igor, Di Carlo, Roberta, Pilato, Serena, Fontana, Antonella, Piattelli, Adriano, Petrović, Sanja, "Biocompatibility and antibiofilm activity of graphene-oxide functionalized titanium discs and collagen membranes" in Dental Materials, 38, no. 7 (2022):1117-1127,
https://doi.org/10.1016/j.dental.2022.04.024 . .
1
5
5