Savić-Stanković, Tatjana

Link to this page

Authority KeyName Variants
orcid::0000-0001-6389-4054
  • Savić-Stanković, Tatjana (1)
  • Savić‐Stanković, Tatjana (1)
Projects

Author's Bibliography

Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting

Miletić, Vesna; Avuthu, Rajiv; Zaprzala, Patrick; Divnić‐Resnik, Tihana; Savić‐Stanković, Tatjana; Cabunac, Jovan; Stašić, Jovana N.; Matić, Tamara

(John Wiley and Sons Inc., 2024)

TY  - JOUR
AU  - Miletić, Vesna
AU  - Avuthu, Rajiv
AU  - Zaprzala, Patrick
AU  - Divnić‐Resnik, Tihana
AU  - Savić‐Stanković, Tatjana
AU  - Cabunac, Jovan
AU  - Stašić, Jovana N.
AU  - Matić, Tamara
PY  - 2024
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7503
AB  - Objectives: To evaluate the effects of enhanced personal protective equipment (Enhanced_PPE) on student-operator's experience and restorative procedure. Methods: Student-operators (N = 29 Year 3 dental students) performed Class II composite restorations (SimpliShade, Kerr) in typodont upper molars (OneDental) equipped with N95 respirators, full-face shields, disposable headwear and gowns (Enhanced_PPE) or surgical masks, protective glasses/goggles and non-disposable gowns (Standard_PPE) 2 weeks later. Cavity dimensions were measured on cone beam computed tomography images. The quality of composite restorations was assessed using selected FDI criteria and Vickers hardness. A questionnaire assessed the operators' discomfort, anxiety, confidence, ability to perform, and procedure outcome. Data were analyzed using paired t-test and McNemar test (alpha = 0.05). Results: Student-operators experienced greater discomfort and anxiety, reduced confidence and ability to perform, and rated the procedure as less satisfactory with Enhanced_PPE (p < 0.05). Differences in proximal box width were marginally significant (Enhanced_PPE 1.8 ± 0.4 mm, Standard_PPE 1.6 ± 0.3 mm) (p = 0.047). Other cavity dimensions were similar between groups (p > 0.05) as were restorations regarding surface luster, anatomical form, marginal adaptation, proximal contour, and contact (p > 0.05). There were no differences in the hardness of composite restorations (top p = 0.349, bottom p = 0.334). Conclusions: Enhanced_PPE led to student-operator discomfort, anxiety, and reduced confidence, but did not impact the quality of Class II preparation and composite restorations versus Standard_PPE.
PB  - John Wiley and Sons Inc.
T2  - Journal of Dental Education
T1  - Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting
DO  - 10.1002/jdd.13593
ER  - 
@article{
author = "Miletić, Vesna and Avuthu, Rajiv and Zaprzala, Patrick and Divnić‐Resnik, Tihana and Savić‐Stanković, Tatjana and Cabunac, Jovan and Stašić, Jovana N. and Matić, Tamara",
year = "2024",
abstract = "Objectives: To evaluate the effects of enhanced personal protective equipment (Enhanced_PPE) on student-operator's experience and restorative procedure. Methods: Student-operators (N = 29 Year 3 dental students) performed Class II composite restorations (SimpliShade, Kerr) in typodont upper molars (OneDental) equipped with N95 respirators, full-face shields, disposable headwear and gowns (Enhanced_PPE) or surgical masks, protective glasses/goggles and non-disposable gowns (Standard_PPE) 2 weeks later. Cavity dimensions were measured on cone beam computed tomography images. The quality of composite restorations was assessed using selected FDI criteria and Vickers hardness. A questionnaire assessed the operators' discomfort, anxiety, confidence, ability to perform, and procedure outcome. Data were analyzed using paired t-test and McNemar test (alpha = 0.05). Results: Student-operators experienced greater discomfort and anxiety, reduced confidence and ability to perform, and rated the procedure as less satisfactory with Enhanced_PPE (p < 0.05). Differences in proximal box width were marginally significant (Enhanced_PPE 1.8 ± 0.4 mm, Standard_PPE 1.6 ± 0.3 mm) (p = 0.047). Other cavity dimensions were similar between groups (p > 0.05) as were restorations regarding surface luster, anatomical form, marginal adaptation, proximal contour, and contact (p > 0.05). There were no differences in the hardness of composite restorations (top p = 0.349, bottom p = 0.334). Conclusions: Enhanced_PPE led to student-operator discomfort, anxiety, and reduced confidence, but did not impact the quality of Class II preparation and composite restorations versus Standard_PPE.",
publisher = "John Wiley and Sons Inc.",
journal = "Journal of Dental Education",
title = "Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting",
doi = "10.1002/jdd.13593"
}
Miletić, V., Avuthu, R., Zaprzala, P., Divnić‐Resnik, T., Savić‐Stanković, T., Cabunac, J., Stašić, J. N.,& Matić, T.. (2024). Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting. in Journal of Dental Education
John Wiley and Sons Inc...
https://doi.org/10.1002/jdd.13593
Miletić V, Avuthu R, Zaprzala P, Divnić‐Resnik T, Savić‐Stanković T, Cabunac J, Stašić JN, Matić T. Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting. in Journal of Dental Education. 2024;.
doi:10.1002/jdd.13593 .
Miletić, Vesna, Avuthu, Rajiv, Zaprzala, Patrick, Divnić‐Resnik, Tihana, Savić‐Stanković, Tatjana, Cabunac, Jovan, Stašić, Jovana N., Matić, Tamara, "Enhanced personal protective equipment and dental students’ experience and quality of a restorative procedure in a simulated clinical setting" in Journal of Dental Education (2024),
https://doi.org/10.1002/jdd.13593 . .

Optical properties of composite restorations influenced by dissimilar dentin restoratives

Marjanović, Jovana; Veljović, Đorđe; Stasić, Jovana; Savić-Stanković, Tatjana; Trifković, Branka; Miletić, Vesna

(Elsevier Sci Ltd, Oxford, 2018)

TY  - JOUR
AU  - Marjanović, Jovana
AU  - Veljović, Đorđe
AU  - Stasić, Jovana
AU  - Savić-Stanković, Tatjana
AU  - Trifković, Branka
AU  - Miletić, Vesna
PY  - 2018
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3999
AB  - Objectives. To evaluate optical properties (color and translucency) of 'sandwich' restorations of resin-based composites and esthetically unfavorable dentin restoratives. Methods. Cylindrical 'dentin' specimens (8 mm in diameter and 2 mm thick, N = 5/group) were prepared using EverX Posterior (GC), Biodentine (Septodont), experimental hydroxyapatite (HAP) or conventional composites (Gradia Direct Posterior, GC; Filtek Z250 and Filtek Z500, 3M ESPE). Capping 'enamel' layers were prepared using composites (Gradia Direct Posterior, Filtek Z250 or Z550) of Al or A3 shade and the following thickness: 0.6, 1 or 2 mm. Color (Delta E) and translucency parameter (TP) were determined using a spectrophotometer (VITA Easyshade Advance 4.0, VITA Zahnfabrik). Data were statistically analyzed using analysis of variance with Tukey's post-hoc tests (alpha = 0.05). Results. TP was greatly affected by layer thickness, whilst Delta E depended on shade and layer thickness of the capping composite. HAP and Biodentine showed significantly lower TP and higher Delta E (deviation from 'ideal white') than composites (p  lt  0.05). Greater TP was seen in EverX_composite groups than in corresponding control groups of the same shade and thickness. TP of composites combined with Biodentine or HAP was below 2, lower than the corresponding control groups (p  lt  0.05). Within-group differences of Delta E were greatest in HAP_composite groups. EverX_Gradia and EverX_FiltekZ250 combinations showed the most comparable Delta E with the control groups. Significance. A 2 mm thick layer of composite covering dentin restoratives with unfavorable esthetics is recommended for a final 'sandwich' restoration that is esthetically comparable to a conventional, mono-composite control restoration.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Optical properties of composite restorations influenced by dissimilar dentin restoratives
EP  - 745
IS  - 5
SP  - 737
VL  - 34
DO  - 10.1016/j.dental.2018.01.017
ER  - 
@article{
author = "Marjanović, Jovana and Veljović, Đorđe and Stasić, Jovana and Savić-Stanković, Tatjana and Trifković, Branka and Miletić, Vesna",
year = "2018",
abstract = "Objectives. To evaluate optical properties (color and translucency) of 'sandwich' restorations of resin-based composites and esthetically unfavorable dentin restoratives. Methods. Cylindrical 'dentin' specimens (8 mm in diameter and 2 mm thick, N = 5/group) were prepared using EverX Posterior (GC), Biodentine (Septodont), experimental hydroxyapatite (HAP) or conventional composites (Gradia Direct Posterior, GC; Filtek Z250 and Filtek Z500, 3M ESPE). Capping 'enamel' layers were prepared using composites (Gradia Direct Posterior, Filtek Z250 or Z550) of Al or A3 shade and the following thickness: 0.6, 1 or 2 mm. Color (Delta E) and translucency parameter (TP) were determined using a spectrophotometer (VITA Easyshade Advance 4.0, VITA Zahnfabrik). Data were statistically analyzed using analysis of variance with Tukey's post-hoc tests (alpha = 0.05). Results. TP was greatly affected by layer thickness, whilst Delta E depended on shade and layer thickness of the capping composite. HAP and Biodentine showed significantly lower TP and higher Delta E (deviation from 'ideal white') than composites (p  lt  0.05). Greater TP was seen in EverX_composite groups than in corresponding control groups of the same shade and thickness. TP of composites combined with Biodentine or HAP was below 2, lower than the corresponding control groups (p  lt  0.05). Within-group differences of Delta E were greatest in HAP_composite groups. EverX_Gradia and EverX_FiltekZ250 combinations showed the most comparable Delta E with the control groups. Significance. A 2 mm thick layer of composite covering dentin restoratives with unfavorable esthetics is recommended for a final 'sandwich' restoration that is esthetically comparable to a conventional, mono-composite control restoration.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Optical properties of composite restorations influenced by dissimilar dentin restoratives",
pages = "745-737",
number = "5",
volume = "34",
doi = "10.1016/j.dental.2018.01.017"
}
Marjanović, J., Veljović, Đ., Stasić, J., Savić-Stanković, T., Trifković, B.,& Miletić, V.. (2018). Optical properties of composite restorations influenced by dissimilar dentin restoratives. in Dental Materials
Elsevier Sci Ltd, Oxford., 34(5), 737-745.
https://doi.org/10.1016/j.dental.2018.01.017
Marjanović J, Veljović Đ, Stasić J, Savić-Stanković T, Trifković B, Miletić V. Optical properties of composite restorations influenced by dissimilar dentin restoratives. in Dental Materials. 2018;34(5):737-745.
doi:10.1016/j.dental.2018.01.017 .
Marjanović, Jovana, Veljović, Đorđe, Stasić, Jovana, Savić-Stanković, Tatjana, Trifković, Branka, Miletić, Vesna, "Optical properties of composite restorations influenced by dissimilar dentin restoratives" in Dental Materials, 34, no. 5 (2018):737-745,
https://doi.org/10.1016/j.dental.2018.01.017 . .
27
10
22