Ivić, Milka Avramov

Link to this page

Authority KeyName Variants
6c8f3340-68fa-49ed-ad27-19f92a674a6b
  • Ivić, Milka Avramov (1)
Projects

Author's Bibliography

Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution

Lović, Jelena; Lađarević, Jelena; Trišović, Nemanja; Andrić, Filip; Mladenović, Aleksandar; Mijin, Dušan; Vuković, Dragan; Petrović, Slobodan; Ivić, Milka Avramov

(2021)

TY  - JOUR
AU  - Lović, Jelena
AU  - Lađarević, Jelena
AU  - Trišović, Nemanja
AU  - Andrić, Filip
AU  - Mladenović, Aleksandar
AU  - Mijin, Dušan
AU  - Vuković, Dragan
AU  - Petrović, Slobodan
AU  - Ivić, Milka Avramov
PY  - 2021
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4896
AB  - The electrochemical characterization of sertraline at gold electrode was examined by cyclic voltammetry measurements (CV) in pH 8.4 bicarbonate buffer. Then Au electrode was evaluated for the quantitative determination of sertraline using square wave voltammetry (SWV). To enhance the sensitivity during the drug determination, (2-hydroxypropyl)-beta-cyclodextrin (HP beta CD) and beta-cyclodextrin (beta CD) inclusion complexes were employed. Using the proposed SWV technique, the anodic current peak was linear within a concentration range of 0.1-0.5 mu M with a limit of detection (LOD) of 2.0 x 10(-8) M and a limit of quantification (LOQ) of 6.7 x 10(-8) M. In the case of inclusion complex of the sertraline with HP beta CD, a good linearity range of 0.1-0.9 mu M was obtained with a LOD of 2.6 x 10(-8) M and a LOQ of 8.8 x 10(-8) M. The gold electrode revealed the same linearity range for inclusion complex of the sertraline with beta CD with a LOD and a LOQ being 2.6 x 10(-8) and 8.6 x 10(-8) M, respectively. Comparing the regression equations, it can be concluded that the sensitivity in the presence of inclusion complex can be up to 5 times higher. The applicability of the developed method was confirmed by the analysis of this drug in pharmaceutical formulation and in human serum spiked with sertraline standard. The comparison to HPLC method was successfully performed. [GRAPHICS] .
T2  - Monatshefte Fur Chemie
T1  - Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution
EP  - 192
IS  - 2
SP  - 185
VL  - 152
DO  - 10.1007/s00706-021-02745-3
ER  - 
@article{
author = "Lović, Jelena and Lađarević, Jelena and Trišović, Nemanja and Andrić, Filip and Mladenović, Aleksandar and Mijin, Dušan and Vuković, Dragan and Petrović, Slobodan and Ivić, Milka Avramov",
year = "2021",
abstract = "The electrochemical characterization of sertraline at gold electrode was examined by cyclic voltammetry measurements (CV) in pH 8.4 bicarbonate buffer. Then Au electrode was evaluated for the quantitative determination of sertraline using square wave voltammetry (SWV). To enhance the sensitivity during the drug determination, (2-hydroxypropyl)-beta-cyclodextrin (HP beta CD) and beta-cyclodextrin (beta CD) inclusion complexes were employed. Using the proposed SWV technique, the anodic current peak was linear within a concentration range of 0.1-0.5 mu M with a limit of detection (LOD) of 2.0 x 10(-8) M and a limit of quantification (LOQ) of 6.7 x 10(-8) M. In the case of inclusion complex of the sertraline with HP beta CD, a good linearity range of 0.1-0.9 mu M was obtained with a LOD of 2.6 x 10(-8) M and a LOQ of 8.8 x 10(-8) M. The gold electrode revealed the same linearity range for inclusion complex of the sertraline with beta CD with a LOD and a LOQ being 2.6 x 10(-8) and 8.6 x 10(-8) M, respectively. Comparing the regression equations, it can be concluded that the sensitivity in the presence of inclusion complex can be up to 5 times higher. The applicability of the developed method was confirmed by the analysis of this drug in pharmaceutical formulation and in human serum spiked with sertraline standard. The comparison to HPLC method was successfully performed. [GRAPHICS] .",
journal = "Monatshefte Fur Chemie",
title = "Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution",
pages = "192-185",
number = "2",
volume = "152",
doi = "10.1007/s00706-021-02745-3"
}
Lović, J., Lađarević, J., Trišović, N., Andrić, F., Mladenović, A., Mijin, D., Vuković, D., Petrović, S.,& Ivić, M. A.. (2021). Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution. in Monatshefte Fur Chemie, 152(2), 185-192.
https://doi.org/10.1007/s00706-021-02745-3
Lović J, Lađarević J, Trišović N, Andrić F, Mladenović A, Mijin D, Vuković D, Petrović S, Ivić MA. Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution. in Monatshefte Fur Chemie. 2021;152(2):185-192.
doi:10.1007/s00706-021-02745-3 .
Lović, Jelena, Lađarević, Jelena, Trišović, Nemanja, Andrić, Filip, Mladenović, Aleksandar, Mijin, Dušan, Vuković, Dragan, Petrović, Slobodan, Ivić, Milka Avramov, "Electrochemical determination of sertraline in pharmaceutical formulation and serum using a gold electrode in a pH 8.4 bicarbonate solution" in Monatshefte Fur Chemie, 152, no. 2 (2021):185-192,
https://doi.org/10.1007/s00706-021-02745-3 . .
5
1
5