Živanović, Miloš Z.

Link to this page

Authority KeyName Variants
orcid::0000-0003-2965-1897
  • Živanović, Miloš Z. (3)
Projects

Author's Bibliography

Radon and thoron exhalation rate measurements from building materials used in Serbia

Čeliković, Igor T.; Pantelić, Gordana K.; Živanović, Miloš Z.; Vukanac, Ivana; Krneta-Nikolić, Jelena D.; Kandić, Aleksandar; Lončar, Boris B.

(2020)

TY  - JOUR
AU  - Čeliković, Igor T.
AU  - Pantelić, Gordana K.
AU  - Živanović, Miloš Z.
AU  - Vukanac, Ivana
AU  - Krneta-Nikolić, Jelena D.
AU  - Kandić, Aleksandar
AU  - Lončar, Boris B.
PY  - 2020
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5891
AB  - The second most important source of indoor radon, after soil beneath dwelling, is building material. With the increase in environmental awareness and new energy-saving policies, residents tend to replace the existing windows with tighter windows, which leads to a decrease in air exchange rate and consequently an increase in indoor radon concentration. In case of low exchange rates, dose caused by inhalation of radon and its progeny can exceed external dose originating from the radium content in the surrounding building material. In this paper, surface exhalation rates of radon ( 222 Rn) and thoron ( 220 Rn) from typical building materials used for construction and interior decoration of houses in Serbia were investigated. Surface exhalation rate measurements were performed using the closed-chamber method, while concentrations of radon and thoron in the chamber were continuously measured using an active device, RTM1688-2, produced by SARAD® GmbH. Finally, the impact of the replacement of windows on the indoor radon concentration was estimated.
T2  - Nukleonika
T1  - Radon and thoron exhalation rate measurements from building materials used in Serbia
EP  - 114
IS  - 2
SP  - 111
VL  - 65
DO  - 10.2478/nuka-2020-0017
ER  - 
@article{
author = "Čeliković, Igor T. and Pantelić, Gordana K. and Živanović, Miloš Z. and Vukanac, Ivana and Krneta-Nikolić, Jelena D. and Kandić, Aleksandar and Lončar, Boris B.",
year = "2020",
abstract = "The second most important source of indoor radon, after soil beneath dwelling, is building material. With the increase in environmental awareness and new energy-saving policies, residents tend to replace the existing windows with tighter windows, which leads to a decrease in air exchange rate and consequently an increase in indoor radon concentration. In case of low exchange rates, dose caused by inhalation of radon and its progeny can exceed external dose originating from the radium content in the surrounding building material. In this paper, surface exhalation rates of radon ( 222 Rn) and thoron ( 220 Rn) from typical building materials used for construction and interior decoration of houses in Serbia were investigated. Surface exhalation rate measurements were performed using the closed-chamber method, while concentrations of radon and thoron in the chamber were continuously measured using an active device, RTM1688-2, produced by SARAD® GmbH. Finally, the impact of the replacement of windows on the indoor radon concentration was estimated.",
journal = "Nukleonika",
title = "Radon and thoron exhalation rate measurements from building materials used in Serbia",
pages = "114-111",
number = "2",
volume = "65",
doi = "10.2478/nuka-2020-0017"
}
Čeliković, I. T., Pantelić, G. K., Živanović, M. Z., Vukanac, I., Krneta-Nikolić, J. D., Kandić, A.,& Lončar, B. B.. (2020). Radon and thoron exhalation rate measurements from building materials used in Serbia. in Nukleonika, 65(2), 111-114.
https://doi.org/10.2478/nuka-2020-0017
Čeliković IT, Pantelić GK, Živanović MZ, Vukanac I, Krneta-Nikolić JD, Kandić A, Lončar BB. Radon and thoron exhalation rate measurements from building materials used in Serbia. in Nukleonika. 2020;65(2):111-114.
doi:10.2478/nuka-2020-0017 .
Čeliković, Igor T., Pantelić, Gordana K., Živanović, Miloš Z., Vukanac, Ivana, Krneta-Nikolić, Jelena D., Kandić, Aleksandar, Lončar, Boris B., "Radon and thoron exhalation rate measurements from building materials used in Serbia" in Nukleonika, 65, no. 2 (2020):111-114,
https://doi.org/10.2478/nuka-2020-0017 . .
3
3

Ad-hoc intercomparison of four different radon exhalation measurement methods

Awhida, Ahmed; Ujić, Predrag; Pantelić, Gordana K.; Kolarž, Predrag M.; Čeliković, Igor T.; Živanović, Miloš Z.; Janićijević, Aco; Lončar, Boris

(Oxford Univ Press, Oxford, 2018)

TY  - JOUR
AU  - Awhida, Ahmed
AU  - Ujić, Predrag
AU  - Pantelić, Gordana K.
AU  - Kolarž, Predrag M.
AU  - Čeliković, Igor T.
AU  - Živanović, Miloš Z.
AU  - Janićijević, Aco
AU  - Lončar, Boris
PY  - 2018
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3953
AB  - It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods of the exhalation measurement, established in our laboratory for the purpose of the intercomparison is reported. Additionally, a comparison of advantages and disadvantages of used methods is discussed.
PB  - Oxford Univ Press, Oxford
T2  - Radiation Protection Dosimetry
T1  - Ad-hoc intercomparison of four different radon exhalation measurement methods
EP  - 142
IS  - 2
SP  - 138
VL  - 178
DO  - 10.1093/rpd/ncx096
ER  - 
@article{
author = "Awhida, Ahmed and Ujić, Predrag and Pantelić, Gordana K. and Kolarž, Predrag M. and Čeliković, Igor T. and Živanović, Miloš Z. and Janićijević, Aco and Lončar, Boris",
year = "2018",
abstract = "It is indicated that the exposure to radon originating from the building materials is not negligible and the radon exhalation measurement should get more attention in the future. The experience with four different methods of the exhalation measurement, established in our laboratory for the purpose of the intercomparison is reported. Additionally, a comparison of advantages and disadvantages of used methods is discussed.",
publisher = "Oxford Univ Press, Oxford",
journal = "Radiation Protection Dosimetry",
title = "Ad-hoc intercomparison of four different radon exhalation measurement methods",
pages = "142-138",
number = "2",
volume = "178",
doi = "10.1093/rpd/ncx096"
}
Awhida, A., Ujić, P., Pantelić, G. K., Kolarž, P. M., Čeliković, I. T., Živanović, M. Z., Janićijević, A.,& Lončar, B.. (2018). Ad-hoc intercomparison of four different radon exhalation measurement methods. in Radiation Protection Dosimetry
Oxford Univ Press, Oxford., 178(2), 138-142.
https://doi.org/10.1093/rpd/ncx096
Awhida A, Ujić P, Pantelić GK, Kolarž PM, Čeliković IT, Živanović MZ, Janićijević A, Lončar B. Ad-hoc intercomparison of four different radon exhalation measurement methods. in Radiation Protection Dosimetry. 2018;178(2):138-142.
doi:10.1093/rpd/ncx096 .
Awhida, Ahmed, Ujić, Predrag, Pantelić, Gordana K., Kolarž, Predrag M., Čeliković, Igor T., Živanović, Miloš Z., Janićijević, Aco, Lončar, Boris, "Ad-hoc intercomparison of four different radon exhalation measurement methods" in Radiation Protection Dosimetry, 178, no. 2 (2018):138-142,
https://doi.org/10.1093/rpd/ncx096 . .
1
1

Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation

Stanković, Srboljub J.; Ilic, R. D.; Živanović, Miloš Z.; Janković, Ksenija S.; Lončar, Boris B.

(2012)

TY  - JOUR
AU  - Stanković, Srboljub J.
AU  - Ilic, R. D.
AU  - Živanović, Miloš Z.
AU  - Janković, Ksenija S.
AU  - Lončar, Boris B.
PY  - 2012
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5714
AB  - Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.
T2  - Acta Physica Polonica A
T1  - Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation
EP  - 658
IS  - 4
SP  - 655
VL  - 122
DO  - 10.12693/APhysPolA.122.655
ER  - 
@article{
author = "Stanković, Srboljub J. and Ilic, R. D. and Živanović, Miloš Z. and Janković, Ksenija S. and Lončar, Boris B.",
year = "2012",
abstract = "Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.",
journal = "Acta Physica Polonica A",
title = "Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation",
pages = "658-655",
number = "4",
volume = "122",
doi = "10.12693/APhysPolA.122.655"
}
Stanković, S. J., Ilic, R. D., Živanović, M. Z., Janković, K. S.,& Lončar, B. B.. (2012). Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation. in Acta Physica Polonica A, 122(4), 655-658.
https://doi.org/10.12693/APhysPolA.122.655
Stanković SJ, Ilic RD, Živanović MZ, Janković KS, Lončar BB. Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation. in Acta Physica Polonica A. 2012;122(4):655-658.
doi:10.12693/APhysPolA.122.655 .
Stanković, Srboljub J., Ilic, R. D., Živanović, Miloš Z., Janković, Ksenija S., Lončar, Boris B., "Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation" in Acta Physica Polonica A, 122, no. 4 (2012):655-658,
https://doi.org/10.12693/APhysPolA.122.655 . .
2
3
3