Kumrić, Ksenija

Link to this page

Authority KeyName Variants
f17ccd1f-a373-4aff-bde6-65b8a028b202
  • Kumrić, Ksenija (1)
Projects

Author's Bibliography

Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry

Trtić-Petrović, Tatjana M.; Đorđević, Jelena S.; Dujaković, Nikolina; Kumrić, Ksenija; Vasiljević, Tatjana; Laušević, Mila

(2010)

TY  - JOUR
AU  - Trtić-Petrović, Tatjana M.
AU  - Đorđević, Jelena S.
AU  - Dujaković, Nikolina
AU  - Kumrić, Ksenija
AU  - Vasiljević, Tatjana
AU  - Laušević, Mila
PY  - 2010
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5590
AB  - An optimised extraction and cleanup method for the analysis of pesticide in natural water samples is presented. Sixteen pesticides of different polarity and from the different chemical classes (organophosphates, triazines, benzimidazoles, carbamates, carbamides, neonicotinoides, methylureas, phenylureas and benzohydrazides), most frequently used in Serbia, were selected for the analysis. Liquid-phase microextraction in a single hollow fibre (HF-LPME) has been applied for sample preparation. The concentrations of pesticides were determined using HPLC-MS/MS method with electrospray ionisation. The extraction behaviour and selection of the experimental conditions was predicted based on log D and pK (a) values of targeted pesticides, which were calculated applying the computer software ACD/Labs PhysChem Suite v12. The influence of the donor pH and concentration of pesticides, organic phase composition as well as the extraction time on the extraction efficiency was investigated. Optimum extraction conditions were evaluated with respect to the investigated parameters of the extraction. The extraction method was validated for 10 out of 16 studied pesticides. Linear range of the pesticides was 0.1-5 A mu g L(-1) with the correlation coefficient from 0.991 to 0.9998, and the relative standard deviation for three standard measurements was between 0.2 and 11.8%. The limits of detections ranged from 0.026 to 0.237 A mu g L(-1) and the limits of quantifications from 0.094 to 0.793 A mu g L(-1). The optimised two-phase HF-LPME method was successfully applied for determination of moderately polar as well low-polar pesticides in the environmental water samples.
T2  - Analytical and Bioanalytical Chemistry
T1  - Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry
EP  - 2243
IS  - 6
SP  - 2233
VL  - 397
DO  - 10.1007/s00216-010-3725-5
ER  - 
@article{
author = "Trtić-Petrović, Tatjana M. and Đorđević, Jelena S. and Dujaković, Nikolina and Kumrić, Ksenija and Vasiljević, Tatjana and Laušević, Mila",
year = "2010",
abstract = "An optimised extraction and cleanup method for the analysis of pesticide in natural water samples is presented. Sixteen pesticides of different polarity and from the different chemical classes (organophosphates, triazines, benzimidazoles, carbamates, carbamides, neonicotinoides, methylureas, phenylureas and benzohydrazides), most frequently used in Serbia, were selected for the analysis. Liquid-phase microextraction in a single hollow fibre (HF-LPME) has been applied for sample preparation. The concentrations of pesticides were determined using HPLC-MS/MS method with electrospray ionisation. The extraction behaviour and selection of the experimental conditions was predicted based on log D and pK (a) values of targeted pesticides, which were calculated applying the computer software ACD/Labs PhysChem Suite v12. The influence of the donor pH and concentration of pesticides, organic phase composition as well as the extraction time on the extraction efficiency was investigated. Optimum extraction conditions were evaluated with respect to the investigated parameters of the extraction. The extraction method was validated for 10 out of 16 studied pesticides. Linear range of the pesticides was 0.1-5 A mu g L(-1) with the correlation coefficient from 0.991 to 0.9998, and the relative standard deviation for three standard measurements was between 0.2 and 11.8%. The limits of detections ranged from 0.026 to 0.237 A mu g L(-1) and the limits of quantifications from 0.094 to 0.793 A mu g L(-1). The optimised two-phase HF-LPME method was successfully applied for determination of moderately polar as well low-polar pesticides in the environmental water samples.",
journal = "Analytical and Bioanalytical Chemistry",
title = "Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry",
pages = "2243-2233",
number = "6",
volume = "397",
doi = "10.1007/s00216-010-3725-5"
}
Trtić-Petrović, T. M., Đorđević, J. S., Dujaković, N., Kumrić, K., Vasiljević, T.,& Laušević, M.. (2010). Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry. in Analytical and Bioanalytical Chemistry, 397(6), 2233-2243.
https://doi.org/10.1007/s00216-010-3725-5
Trtić-Petrović TM, Đorđević JS, Dujaković N, Kumrić K, Vasiljević T, Laušević M. Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry. in Analytical and Bioanalytical Chemistry. 2010;397(6):2233-2243.
doi:10.1007/s00216-010-3725-5 .
Trtić-Petrović, Tatjana M., Đorđević, Jelena S., Dujaković, Nikolina, Kumrić, Ksenija, Vasiljević, Tatjana, Laušević, Mila, "Determination of selected pesticides in environmental water by employing liquid-phase microextraction and liquid chromatography-tandem mass spectrometry" in Analytical and Bioanalytical Chemistry, 397, no. 6 (2010):2233-2243,
https://doi.org/10.1007/s00216-010-3725-5 . .
52
41
49