Hohenwarter, Anton

Link to this page

Authority KeyName Variants
5453e14a-a116-4029-8dd5-0624ca2c970b
  • Hohenwarter, Anton (1)
Projects

Author's Bibliography

The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application

Mihajlović, Dragana; Rakin, Marko; Hohenwarter, Anton; Veljović, Đorđe; Kojić, Vesna; Đokić, Veljko

(Hoboken : John Wiley & Sons, 2024)

TY  - CHAP
AU  - Mihajlović, Dragana
AU  - Rakin, Marko
AU  - Hohenwarter, Anton
AU  - Veljović, Đorđe
AU  - Kojić, Vesna
AU  - Đokić, Veljko
PY  - 2024
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/7147
AB  - Primary implant stability after implantation is in relation with its good mechanical contact with the touching tissue. Adequate integration of the implant with the bone tissue is necessary to provide safety and efficiency of the implant over its life. Generally, two surface properties are the most important facts for tissue response to the implant: the surface topography and chemical composition. Compared to a smooth implant surface, a controlled rough surface provides more surface area for integration with the surrounding tissues and allows successful implant ingrowth into the tissues. It was found that the nanostructured modification of the titanium surface on the level of nano-sized pores influences the adhesion, spreading and growing of osteoblastic cells. There are many methods for nanostructure modification of biomedical alloy surfaces, but one of the common techniques is electrochemical anodization (anodic oxidation). Electrochemical anodization is a method that leads to the creation of a nanotubular oxide film on the material surface. The advantage of anodic oxidation is the possibility of controlling the nanostructured morphology of the surface and dimensions of nanotubes, such as diameter, length, wall thickness and shape of nanotubes through variation of the solution, pH value, potential or duration of anodic oxidation. 
Surface modification of Ti-13Nb-13Zr alloy in a coarse-grained (as received) and ultrafine-grained state induced by high pressure torsion was conducted using an electrochemical anodization process in a 1 M H3PO4 + NaF electrolyte, for 30, 60, 90 and 120 minutes. Scanning electron microscopy (SEM) was used to analyze the morphology, while atomic force microscopy (AFM) was used to characterize the topography of the modified surface. The results showed that a homogenous nanotubular oxide film consisting of nanotubes could be obtained using the electrochemical anodization treatment, while the roughness of the nanostructured surface increased compared to the bare surface. The aim of the studies given in this chapter is to examine the morphology of the nanostructured surface and estimate in vitro biocompatibility of the above-mentioned titanium alloy after the creation of the nanotubular oxide film. In vitro examinations were performed on mouse fibroblast (L929) and human fibroblast (MRC-5) cell lines. The results showed that the nanotubular oxide film obtained on the coarse-grained Ti-13Nb-13Zr alloy (CG TNZ) and the ultrafine-grained Ti-13Nb-13Zr alloy (UFG TNZ) increased the fractions of surviving cells compared to their counterpart alloy, while the cells had better spreading and adhesion on the nanostructured and bare surfaces of the UFG titanium alloy.
PB  - Hoboken : John Wiley & Sons
PB  - Beverly : Scrivener Publishing LLC
T2  - Mechanical Engineering in Biomedical Application: Bio-3D Printing, Biofluid Mechanics, Implant Design, Biomaterials, Computational Biomechanics, Tissue Mechanics
T1  - The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application
EP  - 150
SP  - 121
DO  - 10.1002/9781394175109.ch5
UR  - https://hdl.handle.net/21.15107/rcub_technorep_7147
ER  - 
@inbook{
author = "Mihajlović, Dragana and Rakin, Marko and Hohenwarter, Anton and Veljović, Đorđe and Kojić, Vesna and Đokić, Veljko",
year = "2024",
abstract = "Primary implant stability after implantation is in relation with its good mechanical contact with the touching tissue. Adequate integration of the implant with the bone tissue is necessary to provide safety and efficiency of the implant over its life. Generally, two surface properties are the most important facts for tissue response to the implant: the surface topography and chemical composition. Compared to a smooth implant surface, a controlled rough surface provides more surface area for integration with the surrounding tissues and allows successful implant ingrowth into the tissues. It was found that the nanostructured modification of the titanium surface on the level of nano-sized pores influences the adhesion, spreading and growing of osteoblastic cells. There are many methods for nanostructure modification of biomedical alloy surfaces, but one of the common techniques is electrochemical anodization (anodic oxidation). Electrochemical anodization is a method that leads to the creation of a nanotubular oxide film on the material surface. The advantage of anodic oxidation is the possibility of controlling the nanostructured morphology of the surface and dimensions of nanotubes, such as diameter, length, wall thickness and shape of nanotubes through variation of the solution, pH value, potential or duration of anodic oxidation. 
Surface modification of Ti-13Nb-13Zr alloy in a coarse-grained (as received) and ultrafine-grained state induced by high pressure torsion was conducted using an electrochemical anodization process in a 1 M H3PO4 + NaF electrolyte, for 30, 60, 90 and 120 minutes. Scanning electron microscopy (SEM) was used to analyze the morphology, while atomic force microscopy (AFM) was used to characterize the topography of the modified surface. The results showed that a homogenous nanotubular oxide film consisting of nanotubes could be obtained using the electrochemical anodization treatment, while the roughness of the nanostructured surface increased compared to the bare surface. The aim of the studies given in this chapter is to examine the morphology of the nanostructured surface and estimate in vitro biocompatibility of the above-mentioned titanium alloy after the creation of the nanotubular oxide film. In vitro examinations were performed on mouse fibroblast (L929) and human fibroblast (MRC-5) cell lines. The results showed that the nanotubular oxide film obtained on the coarse-grained Ti-13Nb-13Zr alloy (CG TNZ) and the ultrafine-grained Ti-13Nb-13Zr alloy (UFG TNZ) increased the fractions of surviving cells compared to their counterpart alloy, while the cells had better spreading and adhesion on the nanostructured and bare surfaces of the UFG titanium alloy.",
publisher = "Hoboken : John Wiley & Sons, Beverly : Scrivener Publishing LLC",
journal = "Mechanical Engineering in Biomedical Application: Bio-3D Printing, Biofluid Mechanics, Implant Design, Biomaterials, Computational Biomechanics, Tissue Mechanics",
booktitle = "The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application",
pages = "150-121",
doi = "10.1002/9781394175109.ch5",
url = "https://hdl.handle.net/21.15107/rcub_technorep_7147"
}
Mihajlović, D., Rakin, M., Hohenwarter, A., Veljović, Đ., Kojić, V.,& Đokić, V.. (2024). The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application. in Mechanical Engineering in Biomedical Application: Bio-3D Printing, Biofluid Mechanics, Implant Design, Biomaterials, Computational Biomechanics, Tissue Mechanics
Hoboken : John Wiley & Sons., 121-150.
https://doi.org/10.1002/9781394175109.ch5
https://hdl.handle.net/21.15107/rcub_technorep_7147
Mihajlović D, Rakin M, Hohenwarter A, Veljović Đ, Kojić V, Đokić V. The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application. in Mechanical Engineering in Biomedical Application: Bio-3D Printing, Biofluid Mechanics, Implant Design, Biomaterials, Computational Biomechanics, Tissue Mechanics. 2024;:121-150.
doi:10.1002/9781394175109.ch5
https://hdl.handle.net/21.15107/rcub_technorep_7147 .
Mihajlović, Dragana, Rakin, Marko, Hohenwarter, Anton, Veljović, Đorđe, Kojić, Vesna, Đokić, Veljko, "The Effect of the Nanostructured Surface Modification on the Morphology and Biocompatibility of Ultrafine-Grained Titanium Alloy for Medical Application" in Mechanical Engineering in Biomedical Application: Bio-3D Printing, Biofluid Mechanics, Implant Design, Biomaterials, Computational Biomechanics, Tissue Mechanics (2024):121-150,
https://doi.org/10.1002/9781394175109.ch5 .,
https://hdl.handle.net/21.15107/rcub_technorep_7147 .