Претраживање
Приказ резултата 1-6 од 6
Fabrication of high strength seam welded steel tubes and quality indicator testing / Izrada šavnih cevi od čelika povišene čvrstoće i ispitivanje pokazatelja kvaliteta
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
The selection of steel, the dimensions and methods of fabricating seam welded steel tubes are closely connected to the function of tube as a whole structure in specific working conditions, for a calculated service life. ...
Integrity of biomedical implants of titanium alloys: Second part / Integritet biomedicinskih implanta od legura titana - drugi deo
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
This article reviews the diverse metallic materials for biomedical engineering applications and it is shown that titanium and titanium alloys possess numerous advantages, compared with other biocompatible metallic materials ...
Overhaul and reconstruction of an autoclave / Sanacija i rekonstrukcija autoklava
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
The project of overhaul and redesign of autoclaves, a substantial part of coal drying equipment is realized at the requirement of Kolubara Prerada-Vreoci. Autoclaves operate under pressure at elevated temperature. Frequent ...
Significance of cracks in the heat-affected-zone of steels for elevated temperature application / Značaj prslina u zoni uticaja toplote čelika za povišene temperature
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
Damage and failure of welded joints are classified according to the crack position. Type IV cracking occurs in welded joints in creep-resistant steels, due to enhanced rate of creep void formation in the presence of coarse ...
Integrity of biomedical implants of titanium alloys: First part / Integritet biomedicinskih implanta od legura titana - prvi deo
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
In the paper metallic materials for medical applications are presented, with attention paid to titanium and titanium alloys for biomedical engineering application. Basic properties of metallic materials required for medical ...
Possibility of life assessing the speed reducer for belt conveyor drive by applying tensometric measurements / Mogućnost procene veka prenosnika reduktora za pogon trakastih transportera primenom tenzometrijskih merenja
(Society for Structural Integrity and Life, Institute for Material Testing, 2008)
The load carrying structure of belt conveyors, a system with excessive elastic properties of its parts, is subjected to complex loads of dynamic character. Assessment of state of the drive and conveyor structure is possible ...