Flow-injection chemiluminescence determination of formaldehyde in water
Само за регистроване кориснике
2007
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemi luminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 mu l chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 x 10(-8) to 1 x 10(-5) M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 x 10-8 M. The relative standard deviations for 15 repeated measurements of 1 x 10(-6) and 5 x 10(-6) mol l(-1) HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good... agreement.
Кључне речи:
formaldehyde / chemiluminescence / flow-injection analysis / simplexИзвор:
Talanta, 2007, 71, 2, 900-905Издавач:
- Elsevier Science Bv, Amsterdam
DOI: 10.1016/j.talanta.2006.05.078
ISSN: 0039-9140
PubMed: 19071392
WoS: 000244369600059
Scopus: 2-s2.0-33846307061
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Motyka, Kamil AU - Onjia, Antonije AU - Mikuska, Pavel AU - Vecera, Zbynek PY - 2007 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1076 AB - A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemi luminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 mu l chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 x 10(-8) to 1 x 10(-5) M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 x 10-8 M. The relative standard deviations for 15 repeated measurements of 1 x 10(-6) and 5 x 10(-6) mol l(-1) HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good agreement. PB - Elsevier Science Bv, Amsterdam T2 - Talanta T1 - Flow-injection chemiluminescence determination of formaldehyde in water EP - 905 IS - 2 SP - 900 VL - 71 DO - 10.1016/j.talanta.2006.05.078 ER -
@article{ author = "Motyka, Kamil and Onjia, Antonije and Mikuska, Pavel and Vecera, Zbynek", year = "2007", abstract = "A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemi luminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 mu l chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 x 10(-8) to 1 x 10(-5) M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 x 10-8 M. The relative standard deviations for 15 repeated measurements of 1 x 10(-6) and 5 x 10(-6) mol l(-1) HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good agreement.", publisher = "Elsevier Science Bv, Amsterdam", journal = "Talanta", title = "Flow-injection chemiluminescence determination of formaldehyde in water", pages = "905-900", number = "2", volume = "71", doi = "10.1016/j.talanta.2006.05.078" }
Motyka, K., Onjia, A., Mikuska, P.,& Vecera, Z.. (2007). Flow-injection chemiluminescence determination of formaldehyde in water. in Talanta Elsevier Science Bv, Amsterdam., 71(2), 900-905. https://doi.org/10.1016/j.talanta.2006.05.078
Motyka K, Onjia A, Mikuska P, Vecera Z. Flow-injection chemiluminescence determination of formaldehyde in water. in Talanta. 2007;71(2):900-905. doi:10.1016/j.talanta.2006.05.078 .
Motyka, Kamil, Onjia, Antonije, Mikuska, Pavel, Vecera, Zbynek, "Flow-injection chemiluminescence determination of formaldehyde in water" in Talanta, 71, no. 2 (2007):900-905, https://doi.org/10.1016/j.talanta.2006.05.078 . .