Претраживање
Приказ резултата 1-2 од 2
Failures of brass condenser tubes
(Society for Structural Integrity and Life, Institute for Material Testing, 2016)
Causes of failure of brass condenser tubes (CuZn28Sn1) in a thermal power plant in Serbia are analysed. Results of testing by Fourier transformed infrared spectroscopy (FTIR) have indicated the presence of ammonia and ...
Failures of Brass Condenser Tubes / Lomovi kondenzatorskih cevi od mesinga
(Institut za ispitivanje materijala, Beograd, 2016)
Causes of failure of brass condenser tubes (CuZn28Sn1) in a thermal power plant in Serbia are analysed. Results of testing by Fourier transformed infrared spectroscopy (FTIR) have indicated the presence of ammonia and ...