Development of ion chromatography methods for the determination of trace anions in ultra pure water from power plants
Razvoj metoda jonske hromatografije za određivanje tragova anjona u ultra čistim vodama iz termoelektrana
dc.creator | Čičkarić, Dragana Z. | |
dc.creator | Deršek-Timotić, Ivana | |
dc.creator | Onjia, Antonije | |
dc.creator | Rajaković, Ljubinka V. | |
dc.date.accessioned | 2021-03-10T10:24:17Z | |
dc.date.available | 2021-03-10T10:24:17Z | |
dc.date.issued | 2005 | |
dc.identifier.issn | 0352-5139 | |
dc.identifier.uri | http://TechnoRep.tmf.bg.ac.rs/handle/123456789/796 | |
dc.description.abstract | A suppressed ion chromatography (IC) technique, using a carbonate/hydrogen carbonate or a hydroxide eluent, has been evaluated as a monitoring tool for the detection of major anions (F-, Cl-, NO3-, PO43- and SO42-) in ultra pure water and condensed steam from thermal power plants. An electrical conductivity detector with an anion-exchange column (IonPac AS14), an auto self-regenerating suppressor (ASRS), and an isocratic high-pressure pump system were used for the detection of low concentrations of inorganic anions. It was shown that the suppressed IC technique provides a suitable means for preventing possible damage to generating equipment in power plants. The detection limits of the method for the anions of interest were lt 0.3 μg/L. | en |
dc.description.abstract | Tehnika supresivne jonske hromatografije (IC) razvijena je za analizu tragova anjona (F-, Cl-, NO3-, PO43- and SO42-) u uzorcima ultra čiste vode. Detektor električne provodljivosti sa kolonom za jonsku izmenu (IonPac AS14) samoregenerišući anjonski supresor (ASRS) i izokratična IC pumpa visokog pritiska uspešno su primenjeni za otkrivanje niskih koncentracija neorganskih anjona. Razvijene su dve IC metode, jedna sa karbonatnim (za analizu NO3 PO43- i SO42- -jona), a druga sa hidroksidnim eluentom (za analizu F- i Cl--jona). Granice detekcije primenjenih metoda bile su: lt 0,3 μg/L (metoda sa karbonatnim eluntom) i lt 0,1 μg/L (metoda sa hidroksidnim eluentom). Na ovaj način razvijene su dve IC metode koje se mogu primeniti za kontrolu tragova anjona u sistemu voda-para u termoelektranama. | sr |
dc.publisher | Serbian Chemical Society, Belgrade | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Journal of the Serbian Chemical Society | |
dc.subject | trace analysis | en |
dc.subject | anions | en |
dc.subject | ultra pure water | en |
dc.subject | IC | en |
dc.subject | power plant | en |
dc.title | Development of ion chromatography methods for the determination of trace anions in ultra pure water from power plants | en |
dc.title | Razvoj metoda jonske hromatografije za određivanje tragova anjona u ultra čistim vodama iz termoelektrana | sr |
dc.type | article | |
dc.rights.license | BY-NC-ND | |
dc.citation.epage | 1003 | |
dc.citation.issue | 7 | |
dc.citation.other | 70(7): 995-1003 | |
dc.citation.rank | M23 | |
dc.citation.spage | 995 | |
dc.citation.volume | 70 | |
dc.identifier.fulltext | http://TechnoRep.tmf.bg.ac.rs/bitstream/id/10579/0352-51390507995C.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_technorep_796 | |
dc.identifier.scopus | 2-s2.0-31544474887 | |
dc.identifier.wos | 000231771300010 | |
dc.type.version | publishedVersion |