Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium
Само за регистроване кориснике
2018
Аутори
Stevanović, MilenaĐošić, Marija
Janković, Ana
Kojić, Vesna
Vukašinović-Sekulić, Maja
Stojanović, Jovica
Odović, Jadranka
Crevar-Sakač, Milkica
Rhee, Kyong Yop
Mišković-Stanković, Vesna
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed a...gainst Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic.
Кључне речи:
biocomposite / coatings / electrophoretic deposition / surface analysis / antibacterial activityИзвор:
ACS Biomaterials Science & Engineering, 2018, 4, 12, 3994-4007Издавач:
- Amer Chemical Soc, Washington
Финансирање / пројекти:
- Basic Science Research Program of the Ministry of Education, Science and Technology of Korea [2018R1A2B5A02023190]
- Синтеза, развој технологија добијања и примена наноструктурних мултифункционалних материјала дефинисаних својстава (RS-45019)
DOI: 10.1021/acsbiomaterials.8b00859
ISSN: 2373-9878
WoS: 000453109000008
Scopus: 2-s2.0-85058300298
Колекције
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Stevanović, Milena AU - Đošić, Marija AU - Janković, Ana AU - Kojić, Vesna AU - Vukašinović-Sekulić, Maja AU - Stojanović, Jovica AU - Odović, Jadranka AU - Crevar-Sakač, Milkica AU - Rhee, Kyong Yop AU - Mišković-Stanković, Vesna PY - 2018 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3899 AB - Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed against Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic. PB - Amer Chemical Soc, Washington T2 - ACS Biomaterials Science & Engineering T1 - Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium EP - 4007 IS - 12 SP - 3994 VL - 4 DO - 10.1021/acsbiomaterials.8b00859 ER -
@article{ author = "Stevanović, Milena and Đošić, Marija and Janković, Ana and Kojić, Vesna and Vukašinović-Sekulić, Maja and Stojanović, Jovica and Odović, Jadranka and Crevar-Sakač, Milkica and Rhee, Kyong Yop and Mišković-Stanković, Vesna", year = "2018", abstract = "Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed against Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic.", publisher = "Amer Chemical Soc, Washington", journal = "ACS Biomaterials Science & Engineering", title = "Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium", pages = "4007-3994", number = "12", volume = "4", doi = "10.1021/acsbiomaterials.8b00859" }
Stevanović, M., Đošić, M., Janković, A., Kojić, V., Vukašinović-Sekulić, M., Stojanović, J., Odović, J., Crevar-Sakač, M., Rhee, K. Y.,& Mišković-Stanković, V.. (2018). Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium. in ACS Biomaterials Science & Engineering Amer Chemical Soc, Washington., 4(12), 3994-4007. https://doi.org/10.1021/acsbiomaterials.8b00859
Stevanović M, Đošić M, Janković A, Kojić V, Vukašinović-Sekulić M, Stojanović J, Odović J, Crevar-Sakač M, Rhee KY, Mišković-Stanković V. Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium. in ACS Biomaterials Science & Engineering. 2018;4(12):3994-4007. doi:10.1021/acsbiomaterials.8b00859 .
Stevanović, Milena, Đošić, Marija, Janković, Ana, Kojić, Vesna, Vukašinović-Sekulić, Maja, Stojanović, Jovica, Odović, Jadranka, Crevar-Sakač, Milkica, Rhee, Kyong Yop, Mišković-Stanković, Vesna, "Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium" in ACS Biomaterials Science & Engineering, 4, no. 12 (2018):3994-4007, https://doi.org/10.1021/acsbiomaterials.8b00859 . .