Pressure drop in a countercurrent gas-flowing solids-packed bed contactor
Само за регистроване кориснике
2001
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The equations for prediction of pressure drop in countercurrent gas-flowing solids-packed bed contactors are proposed. The correlations are based on all available data for various constructions, packing elements, and gas and flowing solids properties. The equations give good predictions and are given separately for preloading and loading zones, together with the correlation for the determination of the loading point.
Извор:
Industrial and Engineering Chemistry Research, 2001, 40, 25, 6039-6043Издавач:
- American Chemical Society
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Predojević, Zlatica J. AU - Petrović, Dragan Lj. AU - Duduković, Aleksandar P. PY - 2001 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5345 AB - The equations for prediction of pressure drop in countercurrent gas-flowing solids-packed bed contactors are proposed. The correlations are based on all available data for various constructions, packing elements, and gas and flowing solids properties. The equations give good predictions and are given separately for preloading and loading zones, together with the correlation for the determination of the loading point. PB - American Chemical Society T2 - Industrial and Engineering Chemistry Research T1 - Pressure drop in a countercurrent gas-flowing solids-packed bed contactor EP - 6043 IS - 25 SP - 6039 VL - 40 DO - 10.1021/ie0102798 ER -
@article{ author = "Predojević, Zlatica J. and Petrović, Dragan Lj. and Duduković, Aleksandar P.", year = "2001", abstract = "The equations for prediction of pressure drop in countercurrent gas-flowing solids-packed bed contactors are proposed. The correlations are based on all available data for various constructions, packing elements, and gas and flowing solids properties. The equations give good predictions and are given separately for preloading and loading zones, together with the correlation for the determination of the loading point.", publisher = "American Chemical Society", journal = "Industrial and Engineering Chemistry Research", title = "Pressure drop in a countercurrent gas-flowing solids-packed bed contactor", pages = "6043-6039", number = "25", volume = "40", doi = "10.1021/ie0102798" }
Predojević, Z. J., Petrović, D. Lj.,& Duduković, A. P.. (2001). Pressure drop in a countercurrent gas-flowing solids-packed bed contactor. in Industrial and Engineering Chemistry Research American Chemical Society., 40(25), 6039-6043. https://doi.org/10.1021/ie0102798
Predojević ZJ, Petrović DL, Duduković AP. Pressure drop in a countercurrent gas-flowing solids-packed bed contactor. in Industrial and Engineering Chemistry Research. 2001;40(25):6039-6043. doi:10.1021/ie0102798 .
Predojević, Zlatica J., Petrović, Dragan Lj., Duduković, Aleksandar P., "Pressure drop in a countercurrent gas-flowing solids-packed bed contactor" in Industrial and Engineering Chemistry Research, 40, no. 25 (2001):6039-6043, https://doi.org/10.1021/ie0102798 . .