Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index
Gasnohromatografski retencioni indeksi n-supstituisanih Amino derivata s-triazina na kapilarnim kolonama. Deo V. Uticaj temperature na retencioni indeks
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
The temperature dependence of the retention index was studied for N-substituted amino s-triazines on DB-1, DB-5 and DB-WAX capillary columns within the temperature range 190–230 ºC. Two linear equations with the column temperature and its reciprocal as variables were studied. The first one shows a slightly better precision for 2,4-bis(alky lamino)-6-chloro-s-triazines and 2-alkylamino-4,6-dichloro-s-triazines while the second one shows a better precision for 2,4-bis(cycloalkylamino)-6-chloro-s-triazines.
U radu je prikazana linearna zavisnost retencionog indeksa od temperature korišćenjem linearnih zavisnosti retencionog indeksa u funkciji temperature kolone t, ºC ili 1/T, K–1 za s-triazine na kapilarnim kolonama DB-1, DB-5 i DB-WAX u temperaturnom intervalu 190–230 ºC.
Ključne reči:
retention indices / s-triazines / temperature dependenceIzvor:
Journal of the Serbian Chemical Society, 2003, 68, 11, 825-831Izdavač:
- Serbian Chemical Society, Belgrade
Institucija/grupa
Tehnološko-metalurški fakultetTY - JOUR AU - Mijin, Dušan AU - Antonović, Dušan AU - Jovanović, Bratislav Ž. PY - 2003 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/583 AB - The temperature dependence of the retention index was studied for N-substituted amino s-triazines on DB-1, DB-5 and DB-WAX capillary columns within the temperature range 190–230 ºC. Two linear equations with the column temperature and its reciprocal as variables were studied. The first one shows a slightly better precision for 2,4-bis(alky lamino)-6-chloro-s-triazines and 2-alkylamino-4,6-dichloro-s-triazines while the second one shows a better precision for 2,4-bis(cycloalkylamino)-6-chloro-s-triazines. AB - U radu je prikazana linearna zavisnost retencionog indeksa od temperature korišćenjem linearnih zavisnosti retencionog indeksa u funkciji temperature kolone t, ºC ili 1/T, K–1 za s-triazine na kapilarnim kolonama DB-1, DB-5 i DB-WAX u temperaturnom intervalu 190–230 ºC. PB - Serbian Chemical Society, Belgrade T2 - Journal of the Serbian Chemical Society T1 - Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index T1 - Gasnohromatografski retencioni indeksi n-supstituisanih Amino derivata s-triazina na kapilarnim kolonama. Deo V. Uticaj temperature na retencioni indeks EP - 831 IS - 11 SP - 825 VL - 68 UR - https://hdl.handle.net/21.15107/rcub_technorep_583 ER -
@article{ author = "Mijin, Dušan and Antonović, Dušan and Jovanović, Bratislav Ž.", year = "2003", abstract = "The temperature dependence of the retention index was studied for N-substituted amino s-triazines on DB-1, DB-5 and DB-WAX capillary columns within the temperature range 190–230 ºC. Two linear equations with the column temperature and its reciprocal as variables were studied. The first one shows a slightly better precision for 2,4-bis(alky lamino)-6-chloro-s-triazines and 2-alkylamino-4,6-dichloro-s-triazines while the second one shows a better precision for 2,4-bis(cycloalkylamino)-6-chloro-s-triazines., U radu je prikazana linearna zavisnost retencionog indeksa od temperature korišćenjem linearnih zavisnosti retencionog indeksa u funkciji temperature kolone t, ºC ili 1/T, K–1 za s-triazine na kapilarnim kolonama DB-1, DB-5 i DB-WAX u temperaturnom intervalu 190–230 ºC.", publisher = "Serbian Chemical Society, Belgrade", journal = "Journal of the Serbian Chemical Society", title = "Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index, Gasnohromatografski retencioni indeksi n-supstituisanih Amino derivata s-triazina na kapilarnim kolonama. Deo V. Uticaj temperature na retencioni indeks", pages = "831-825", number = "11", volume = "68", url = "https://hdl.handle.net/21.15107/rcub_technorep_583" }
Mijin, D., Antonović, D.,& Jovanović, B. Ž.. (2003). Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index. in Journal of the Serbian Chemical Society Serbian Chemical Society, Belgrade., 68(11), 825-831. https://hdl.handle.net/21.15107/rcub_technorep_583
Mijin D, Antonović D, Jovanović BŽ. Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index. in Journal of the Serbian Chemical Society. 2003;68(11):825-831. https://hdl.handle.net/21.15107/rcub_technorep_583 .
Mijin, Dušan, Antonović, Dušan, Jovanović, Bratislav Ž., "Gas chromatographic retention indices for N-substituted amino s-triazines on capillary columns. Part V. Temperature dependence of the retention index" in Journal of the Serbian Chemical Society, 68, no. 11 (2003):825-831, https://hdl.handle.net/21.15107/rcub_technorep_583 .