Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors
Samo za registrovane korisnike
2004
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
A model based on first principles and free of any semiempirical parameters is presented for trickling solids holdup in gas-flowing solids-fixed bed contactors. A small double-cone cavity is used to characterize the voids in packed beds. A comparison of model-predicted value holdup and numerous values reported in the literature is presented.
Izvor:
Industrial & Engineering Chemistry Research, 2004, 43, 23, 7445-7448Izdavač:
- Amer Chemical Soc, Washington
DOI: 10.1021/ie0401105
ISSN: 0888-5885
WoS: 000224977600025
Scopus: 2-s2.0-8344221286
Institucija/grupa
Tehnološko-metalurški fakultetTY - JOUR AU - Duduković, Aleksandar AU - Nikačević, Nikola AU - Kuzeljević, Željko V. PY - 2004 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/706 AB - A model based on first principles and free of any semiempirical parameters is presented for trickling solids holdup in gas-flowing solids-fixed bed contactors. A small double-cone cavity is used to characterize the voids in packed beds. A comparison of model-predicted value holdup and numerous values reported in the literature is presented. PB - Amer Chemical Soc, Washington T2 - Industrial & Engineering Chemistry Research T1 - Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors EP - 7448 IS - 23 SP - 7445 VL - 43 DO - 10.1021/ie0401105 ER -
@article{ author = "Duduković, Aleksandar and Nikačević, Nikola and Kuzeljević, Željko V.", year = "2004", abstract = "A model based on first principles and free of any semiempirical parameters is presented for trickling solids holdup in gas-flowing solids-fixed bed contactors. A small double-cone cavity is used to characterize the voids in packed beds. A comparison of model-predicted value holdup and numerous values reported in the literature is presented.", publisher = "Amer Chemical Soc, Washington", journal = "Industrial & Engineering Chemistry Research", title = "Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors", pages = "7448-7445", number = "23", volume = "43", doi = "10.1021/ie0401105" }
Duduković, A., Nikačević, N.,& Kuzeljević, Ž. V.. (2004). Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors. in Industrial & Engineering Chemistry Research Amer Chemical Soc, Washington., 43(23), 7445-7448. https://doi.org/10.1021/ie0401105
Duduković A, Nikačević N, Kuzeljević ŽV. Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors. in Industrial & Engineering Chemistry Research. 2004;43(23):7445-7448. doi:10.1021/ie0401105 .
Duduković, Aleksandar, Nikačević, Nikola, Kuzeljević, Željko V., "Modeling and predictions of solids dynamic holdup in gas-flowing solids-fixed bed contactors" in Industrial & Engineering Chemistry Research, 43, no. 23 (2004):7445-7448, https://doi.org/10.1021/ie0401105 . .