Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors
Razmena čestica između pokretne i nepokretne zone u kontaktorima gas-pokretna čvrsta faza-pakovan sloj
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
In countercurrent gas - flowing solids - fixed bed contactors, a fraction of the flowing solids is in motion (dynamic holdup), while the other fraction is resting on the fixed bed elements. In this study it was experimentally proved that the stagnant zone should not be considered as a dead part of the column, but that there is a dynamic exchange between these two portions of flowing solids particles. Combining a mathematical model with tracer experiments, the rate of exchange was determined and it was shown that only a small part (ca. 20 %) of the stagnant region should be considered as a dead one.
Kontaktori gas-pokretna čvrsta faza-pokovan sloj predstavljaju novi tip uređaja za separacione procese, prenos toplote i hemijske reaktore. U ovom tipu kontaktora gas struji na gore kroz pakovan sloj u koloni, dok sitne čestice pokretne čvrste faze struje na dole. Pokretnu čvrstu fazu karakterišu dinamički i statički sadržaj, jer se deo čestica nalazi u kretanju, dok drugi deo čestica miruje nataložen na elementima pakovanja. U ovom radu je pretpostavljeno i eksperimentalno dokazano da nataložene čestice na pakovanju ne predstavljaju neaktivni (mrtvi) deo pokretne čvrste faze, kao što se do sada pretpostavljalo, već postoji stalna razmena između pokretnih čestica u toku (dinamički sadržaj) i onih koje su nataložene (statički sadržaj). Primenom tehnike sa obeleženom supstancom pokazano je da samo mali deo nataloženih čestica na punjenju (oko 20 %) ne biva zamenjeno ni posle veoma dugog vremena i zaista predstavlja "mrtvu zonu". Kombinovanjem izvedenog matematičkog modela sa eksperimenta...lnim rezultatima određena je brzina razmene pokretnih i nepokretnih čestica.
Кључне речи:
gas-flowing solids-fixed bed contactors / gas-solids trickle flow / multiphase contactors / tracersИзвор:
Journal of the Serbian Chemical Society, 2005, 70, 1, 137-144Издавач:
- Serbian Chemical Society, Belgrade
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Duduković, Aleksandar AU - Nikačević, Nikola AU - Pjanović, Rada AU - Kuzeljević, Željko V. PY - 2005 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/774 AB - In countercurrent gas - flowing solids - fixed bed contactors, a fraction of the flowing solids is in motion (dynamic holdup), while the other fraction is resting on the fixed bed elements. In this study it was experimentally proved that the stagnant zone should not be considered as a dead part of the column, but that there is a dynamic exchange between these two portions of flowing solids particles. Combining a mathematical model with tracer experiments, the rate of exchange was determined and it was shown that only a small part (ca. 20 %) of the stagnant region should be considered as a dead one. AB - Kontaktori gas-pokretna čvrsta faza-pokovan sloj predstavljaju novi tip uređaja za separacione procese, prenos toplote i hemijske reaktore. U ovom tipu kontaktora gas struji na gore kroz pakovan sloj u koloni, dok sitne čestice pokretne čvrste faze struje na dole. Pokretnu čvrstu fazu karakterišu dinamički i statički sadržaj, jer se deo čestica nalazi u kretanju, dok drugi deo čestica miruje nataložen na elementima pakovanja. U ovom radu je pretpostavljeno i eksperimentalno dokazano da nataložene čestice na pakovanju ne predstavljaju neaktivni (mrtvi) deo pokretne čvrste faze, kao što se do sada pretpostavljalo, već postoji stalna razmena između pokretnih čestica u toku (dinamički sadržaj) i onih koje su nataložene (statički sadržaj). Primenom tehnike sa obeleženom supstancom pokazano je da samo mali deo nataloženih čestica na punjenju (oko 20 %) ne biva zamenjeno ni posle veoma dugog vremena i zaista predstavlja "mrtvu zonu". Kombinovanjem izvedenog matematičkog modela sa eksperimentalnim rezultatima određena je brzina razmene pokretnih i nepokretnih čestica. PB - Serbian Chemical Society, Belgrade T2 - Journal of the Serbian Chemical Society T1 - Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors T1 - Razmena čestica između pokretne i nepokretne zone u kontaktorima gas-pokretna čvrsta faza-pakovan sloj EP - 144 IS - 1 SP - 137 VL - 70 UR - https://hdl.handle.net/21.15107/rcub_technorep_774 ER -
@article{ author = "Duduković, Aleksandar and Nikačević, Nikola and Pjanović, Rada and Kuzeljević, Željko V.", year = "2005", abstract = "In countercurrent gas - flowing solids - fixed bed contactors, a fraction of the flowing solids is in motion (dynamic holdup), while the other fraction is resting on the fixed bed elements. In this study it was experimentally proved that the stagnant zone should not be considered as a dead part of the column, but that there is a dynamic exchange between these two portions of flowing solids particles. Combining a mathematical model with tracer experiments, the rate of exchange was determined and it was shown that only a small part (ca. 20 %) of the stagnant region should be considered as a dead one., Kontaktori gas-pokretna čvrsta faza-pokovan sloj predstavljaju novi tip uređaja za separacione procese, prenos toplote i hemijske reaktore. U ovom tipu kontaktora gas struji na gore kroz pakovan sloj u koloni, dok sitne čestice pokretne čvrste faze struje na dole. Pokretnu čvrstu fazu karakterišu dinamički i statički sadržaj, jer se deo čestica nalazi u kretanju, dok drugi deo čestica miruje nataložen na elementima pakovanja. U ovom radu je pretpostavljeno i eksperimentalno dokazano da nataložene čestice na pakovanju ne predstavljaju neaktivni (mrtvi) deo pokretne čvrste faze, kao što se do sada pretpostavljalo, već postoji stalna razmena između pokretnih čestica u toku (dinamički sadržaj) i onih koje su nataložene (statički sadržaj). Primenom tehnike sa obeleženom supstancom pokazano je da samo mali deo nataloženih čestica na punjenju (oko 20 %) ne biva zamenjeno ni posle veoma dugog vremena i zaista predstavlja "mrtvu zonu". Kombinovanjem izvedenog matematičkog modela sa eksperimentalnim rezultatima određena je brzina razmene pokretnih i nepokretnih čestica.", publisher = "Serbian Chemical Society, Belgrade", journal = "Journal of the Serbian Chemical Society", title = "Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors, Razmena čestica između pokretne i nepokretne zone u kontaktorima gas-pokretna čvrsta faza-pakovan sloj", pages = "144-137", number = "1", volume = "70", url = "https://hdl.handle.net/21.15107/rcub_technorep_774" }
Duduković, A., Nikačević, N., Pjanović, R.,& Kuzeljević, Ž. V.. (2005). Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors. in Journal of the Serbian Chemical Society Serbian Chemical Society, Belgrade., 70(1), 137-144. https://hdl.handle.net/21.15107/rcub_technorep_774
Duduković A, Nikačević N, Pjanović R, Kuzeljević ŽV. Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors. in Journal of the Serbian Chemical Society. 2005;70(1):137-144. https://hdl.handle.net/21.15107/rcub_technorep_774 .
Duduković, Aleksandar, Nikačević, Nikola, Pjanović, Rada, Kuzeljević, Željko V., "Exchange between the stagnant and flowing zone in gas-flowing solids-fixed bed contactors" in Journal of the Serbian Chemical Society, 70, no. 1 (2005):137-144, https://hdl.handle.net/21.15107/rcub_technorep_774 .