TechnoRep - Faculty of Technology and Metallurgy Repository
University of Belgrade - Faculty of Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   TechnoRep
  • Tehnološko-metalurški fakultet
  • Radovi istraživača / Researchers’ publications (TMF)
  • View Item
  •   TechnoRep
  • Tehnološko-metalurški fakultet
  • Radovi istraživača / Researchers’ publications (TMF)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition

Authorized Users Only
2007
Authors
Tanasković, Dušanka
Jokić, Bojan
Socol, Gabriel
Popescu, A. C.
Mihailescu, Ion N.
Petrović, Rada
Janaćković, Đorđe
Article (Published version)
Metadata
Show full item record
Abstract
Functionally graded glass-apatite multistructures were synthesized by pulsed laser deposition on Ti substrates. We used sintered targets of hydroxyapatite Ca-10(PO4)(6)(OH)(2), or bioglasses in the system SiO2-Na2O-K2O-CaO-MgO-P2O5 with SiO2 content of either 57 wt.% (6P57) or 61 wt.% (061). A UV KrF* (lambda = 248 nm, tau gt 7 ns) excimer laser source was used for the multipulse laser ablation of the targets. The hydroxyapatite thin films were obtained in H2O Vapors, while the bioglass layers were deposited in O-2. Thin films of 6P61 were deposited in direct contact with Ti, because Ti and this glass have similar thermal expansion behaviors, which ensure good bioglass adhesion to the substrate. This glass, however, is not bioactive, so yet more depositions of 6P57 bioglass and/or hydroxyapatite thin films were performed. All structures with hydroxyapatite overcoating were post-treated in a flux of water vapors. The obtained multistructures were characterized by various techniques. X...ray investigations of the coatings found small amounts of crystalline hydroxyapatite in the outer layers. The scanning electron microscopy analyses revealed homogeneous coatings with good adhesion to the Ti substrate. Our studies showed that the multistructures we had obtained were compatible with further use in biomimetic metallic implants with glass-apatite coating applications.

Keywords:
biomimetic metallic implants / bioglasses / bioactive thin layers / pulsed laser deposition
Source:
Applied Surface Science, 2007, 254, 4, 1279-1282
Publisher:
  • Elsevier Science Bv, Amsterdam
Funding / projects:
  • Sinteza, struktura, svojstva i primena funkcionalnih nanostrukturnih keramičkih i biokeramičkih materijala (RS-142070)

DOI: 10.1016/j.apsusc.2007.08.009

ISSN: 0169-4332

WoS: 000252299500100

Scopus: 2-s2.0-36348943087
[ Google Scholar ]
42
37
URI
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1149
Collections
  • Radovi istraživača / Researchers’ publications (TMF)
Institution/Community
Tehnološko-metalurški fakultet
TY  - JOUR
AU  - Tanasković, Dušanka
AU  - Jokić, Bojan
AU  - Socol, Gabriel
AU  - Popescu, A. C.
AU  - Mihailescu, Ion N.
AU  - Petrović, Rada
AU  - Janaćković, Đorđe
PY  - 2007
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1149
AB  - Functionally graded glass-apatite multistructures were synthesized by pulsed laser deposition on Ti substrates. We used sintered targets of hydroxyapatite Ca-10(PO4)(6)(OH)(2), or bioglasses in the system SiO2-Na2O-K2O-CaO-MgO-P2O5 with SiO2 content of either 57 wt.% (6P57) or 61 wt.% (061). A UV KrF* (lambda = 248 nm, tau  gt  7 ns) excimer laser source was used for the multipulse laser ablation of the targets. The hydroxyapatite thin films were obtained in H2O Vapors, while the bioglass layers were deposited in O-2. Thin films of 6P61 were deposited in direct contact with Ti, because Ti and this glass have similar thermal expansion behaviors, which ensure good bioglass adhesion to the substrate. This glass, however, is not bioactive, so yet more depositions of 6P57 bioglass and/or hydroxyapatite thin films were performed. All structures with hydroxyapatite overcoating were post-treated in a flux of water vapors. The obtained multistructures were characterized by various techniques. Xray investigations of the coatings found small amounts of crystalline hydroxyapatite in the outer layers. The scanning electron microscopy analyses revealed homogeneous coatings with good adhesion to the Ti substrate. Our studies showed that the multistructures we had obtained were compatible with further use in biomimetic metallic implants with glass-apatite coating applications.
PB  - Elsevier Science Bv, Amsterdam
T2  - Applied Surface Science
T1  - Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition
EP  - 1282
IS  - 4
SP  - 1279
VL  - 254
DO  - 10.1016/j.apsusc.2007.08.009
ER  - 
@article{
author = "Tanasković, Dušanka and Jokić, Bojan and Socol, Gabriel and Popescu, A. C. and Mihailescu, Ion N. and Petrović, Rada and Janaćković, Đorđe",
year = "2007",
abstract = "Functionally graded glass-apatite multistructures were synthesized by pulsed laser deposition on Ti substrates. We used sintered targets of hydroxyapatite Ca-10(PO4)(6)(OH)(2), or bioglasses in the system SiO2-Na2O-K2O-CaO-MgO-P2O5 with SiO2 content of either 57 wt.% (6P57) or 61 wt.% (061). A UV KrF* (lambda = 248 nm, tau  gt  7 ns) excimer laser source was used for the multipulse laser ablation of the targets. The hydroxyapatite thin films were obtained in H2O Vapors, while the bioglass layers were deposited in O-2. Thin films of 6P61 were deposited in direct contact with Ti, because Ti and this glass have similar thermal expansion behaviors, which ensure good bioglass adhesion to the substrate. This glass, however, is not bioactive, so yet more depositions of 6P57 bioglass and/or hydroxyapatite thin films were performed. All structures with hydroxyapatite overcoating were post-treated in a flux of water vapors. The obtained multistructures were characterized by various techniques. Xray investigations of the coatings found small amounts of crystalline hydroxyapatite in the outer layers. The scanning electron microscopy analyses revealed homogeneous coatings with good adhesion to the Ti substrate. Our studies showed that the multistructures we had obtained were compatible with further use in biomimetic metallic implants with glass-apatite coating applications.",
publisher = "Elsevier Science Bv, Amsterdam",
journal = "Applied Surface Science",
title = "Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition",
pages = "1282-1279",
number = "4",
volume = "254",
doi = "10.1016/j.apsusc.2007.08.009"
}
Tanasković, D., Jokić, B., Socol, G., Popescu, A. C., Mihailescu, I. N., Petrović, R.,& Janaćković, Đ.. (2007). Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition. in Applied Surface Science
Elsevier Science Bv, Amsterdam., 254(4), 1279-1282.
https://doi.org/10.1016/j.apsusc.2007.08.009
Tanasković D, Jokić B, Socol G, Popescu AC, Mihailescu IN, Petrović R, Janaćković Đ. Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition. in Applied Surface Science. 2007;254(4):1279-1282.
doi:10.1016/j.apsusc.2007.08.009 .
Tanasković, Dušanka, Jokić, Bojan, Socol, Gabriel, Popescu, A. C., Mihailescu, Ion N., Petrović, Rada, Janaćković, Đorđe, "Synthesis of functionally graded bioactive glass-apatite multistructures on Ti substrates by pulsed laser deposition" in Applied Surface Science, 254, no. 4 (2007):1279-1282,
https://doi.org/10.1016/j.apsusc.2007.08.009 . .

DSpace software copyright © 2002-2015  DuraSpace
About TechnoRep | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About TechnoRep | Send Feedback

OpenAIRERCUB