Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger
Само за регистроване кориснике
2008
Конференцијски прилог (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008).
Извор:
CHISA 2008 - 18th International Congress of Chemical and Process Engineering, 2008Издавач:
- 18th International Congress of Chemical and Process Engineering, CHISA 2008
Институција/група
Tehnološko-metalurški fakultetTY - CONF AU - Živković, Emila AU - Kabelac, Stephan AU - Šerbanović, Slobodan P. PY - 2008 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1214 AB - The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008). PB - 18th International Congress of Chemical and Process Engineering, CHISA 2008 C3 - CHISA 2008 - 18th International Congress of Chemical and Process Engineering T1 - Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger UR - https://hdl.handle.net/21.15107/rcub_technorep_1214 ER -
@conference{ author = "Živković, Emila and Kabelac, Stephan and Šerbanović, Slobodan P.", year = "2008", abstract = "The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008).", publisher = "18th International Congress of Chemical and Process Engineering, CHISA 2008", journal = "CHISA 2008 - 18th International Congress of Chemical and Process Engineering", title = "Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger", url = "https://hdl.handle.net/21.15107/rcub_technorep_1214" }
Živković, E., Kabelac, S.,& Šerbanović, S. P.. (2008). Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger. in CHISA 2008 - 18th International Congress of Chemical and Process Engineering 18th International Congress of Chemical and Process Engineering, CHISA 2008.. https://hdl.handle.net/21.15107/rcub_technorep_1214
Živković E, Kabelac S, Šerbanović SP. Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger. in CHISA 2008 - 18th International Congress of Chemical and Process Engineering. 2008;. https://hdl.handle.net/21.15107/rcub_technorep_1214 .
Živković, Emila, Kabelac, Stephan, Šerbanović, Slobodan P., "Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger" in CHISA 2008 - 18th International Congress of Chemical and Process Engineering (2008), https://hdl.handle.net/21.15107/rcub_technorep_1214 .