Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger

Samo za registrovane korisnike
2008
Autori
Živković, Emila
Kabelac, Stephan
Šerbanović, Slobodan P.
Konferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008).
Izvor:
CHISA 2008 - 18th International Congress of Chemical and Process Engineering, 2008
Izdavač:
  • 18th International Congress of Chemical and Process Engineering, CHISA 2008

ISBN: 978-800202054-7

PubMed:

Scopus: 2-s2.0-84873409334
[ Google Scholar ]
Handle
https://hdl.handle.net/21.15107/rcub_technorep_1214
URI
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1214
Kolekcije
  • Radovi istraživača / Researchers’ publications (TMF)
Institucija/grupa
Tehnološko-metalurški fakultet
TY  - CONF
AU  - Živković, Emila
AU  - Kabelac, Stephan
AU  - Šerbanović, Slobodan P.
PY  - 2008
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1214
AB  - The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008).
PB  - 18th International Congress of Chemical and Process Engineering, CHISA 2008
C3  - CHISA 2008 - 18th International Congress of Chemical and Process Engineering
T1  - Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger
UR  - https://hdl.handle.net/21.15107/rcub_technorep_1214
ER  - 
@conference{
author = "Živković, Emila and Kabelac, Stephan and Šerbanović, Slobodan P.",
year = "2008",
abstract = "The evaporation heat transfer coefficient of refrigerant R-134a in a vertical plate heat exchanger was investigated. The area of the plate was divided into several segments along the vertical axis. For each of the segments, the local value of the heat transfer coefficient was calculated and presented as a function of the mean vapor quality in the segment. The temperature distribution and vapor quality profile inside the plate were determined. The influences of the mass flux, heat flux, system pressure, and flow configuration on the heat transfer coefficient were accounted for and a comparison with published data was carried out. This is an abstract of a paper presented at the 18th International Congress of Chemical and Process Engineering (Prague, Czech Republic 8/24-28/2008).",
publisher = "18th International Congress of Chemical and Process Engineering, CHISA 2008",
journal = "CHISA 2008 - 18th International Congress of Chemical and Process Engineering",
title = "Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger",
url = "https://hdl.handle.net/21.15107/rcub_technorep_1214"
}
Živković, E., Kabelac, S.,& Šerbanović, S. P.. (2008). Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger. in CHISA 2008 - 18th International Congress of Chemical and Process Engineering
18th International Congress of Chemical and Process Engineering, CHISA 2008..
https://hdl.handle.net/21.15107/rcub_technorep_1214
Živković E, Kabelac S, Šerbanović SP. Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger. in CHISA 2008 - 18th International Congress of Chemical and Process Engineering. 2008;.
https://hdl.handle.net/21.15107/rcub_technorep_1214 .
Živković, Emila, Kabelac, Stephan, Šerbanović, Slobodan P., "Local heat transfer coefficients during refrigerant R-134a evaporation in a vertical plate heat exchanger" in CHISA 2008 - 18th International Congress of Chemical and Process Engineering (2008),
https://hdl.handle.net/21.15107/rcub_technorep_1214 .

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu TechnoRep | Pošaljite zapažanja

OpenAIRERCUB
 

 

Kompletan repozitorijumInstitucije/grupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O repozitorijumu TechnoRep | Pošaljite zapažanja

OpenAIRERCUB