Voltammetric and differential pulse determination of roxithromycin
Authorized Users Only
2010
Authors
Drljević-Đurić, KaticaJović, Vladimir D.

Lačnjevac, Uroš

Avramov-Ivić, Milka

Petrović, Slobodan
Mijin, Dušan

Đorđević, S. B.
Article (Published version)

Metadata
Show full item recordAbstract
The oxidative behavior of antibiotic roxithromycin standard was studied at a gold electrode in 0.05 M NaHCO3 using cyclic linear sweep voltammetry and differential pulse voltammetry. It was found that the value of the oxidative peak of pure roxithromycin at 0.81 V vs. SCE in 0.05 M NaHCO3 at a scan rate of 50 mV s(-1) is a linear function of the concentration in a range 0.10006-0.654 mg cm(-3). It was also found that peak current density at 0.75 V vs. SCE at a scan rate of 2 mVs(-1), pulse amplitude of 25 mV and pulse time of 0.1 s exhibits linear dependence on the concentration of roxithromycin from 0.1006 to 0.476 mg cm(-3). Roxithromycin as a content of solid dosage form and urine was quantitatively determined and the obtained results were checked by HPLC.
Keywords:
Roxithromycin / Gold electrode / Cyclic voltammetry / Differential pulse voltammetrySource:
Electrochimica Acta, 2010, 56, 1, 47-52Publisher:
- Pergamon-Elsevier Science Ltd, Oxford
Funding / projects:
- Proučavanje sinteze, strukture i aktivnosti organskih jedinjenja prirodnog i sintetskog porekla (RS-142063)
DOI: 10.1016/j.electacta.2010.09.067
ISSN: 0013-4686
WoS: 000285177800005
Scopus: 2-s2.0-78649992513
Institution/Community
Tehnološko-metalurški fakultetTY - JOUR AU - Drljević-Đurić, Katica AU - Jović, Vladimir D. AU - Lačnjevac, Uroš AU - Avramov-Ivić, Milka AU - Petrović, Slobodan AU - Mijin, Dušan AU - Đorđević, S. B. PY - 2010 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1718 AB - The oxidative behavior of antibiotic roxithromycin standard was studied at a gold electrode in 0.05 M NaHCO3 using cyclic linear sweep voltammetry and differential pulse voltammetry. It was found that the value of the oxidative peak of pure roxithromycin at 0.81 V vs. SCE in 0.05 M NaHCO3 at a scan rate of 50 mV s(-1) is a linear function of the concentration in a range 0.10006-0.654 mg cm(-3). It was also found that peak current density at 0.75 V vs. SCE at a scan rate of 2 mVs(-1), pulse amplitude of 25 mV and pulse time of 0.1 s exhibits linear dependence on the concentration of roxithromycin from 0.1006 to 0.476 mg cm(-3). Roxithromycin as a content of solid dosage form and urine was quantitatively determined and the obtained results were checked by HPLC. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - Electrochimica Acta T1 - Voltammetric and differential pulse determination of roxithromycin EP - 52 IS - 1 SP - 47 VL - 56 DO - 10.1016/j.electacta.2010.09.067 ER -
@article{ author = "Drljević-Đurić, Katica and Jović, Vladimir D. and Lačnjevac, Uroš and Avramov-Ivić, Milka and Petrović, Slobodan and Mijin, Dušan and Đorđević, S. B.", year = "2010", abstract = "The oxidative behavior of antibiotic roxithromycin standard was studied at a gold electrode in 0.05 M NaHCO3 using cyclic linear sweep voltammetry and differential pulse voltammetry. It was found that the value of the oxidative peak of pure roxithromycin at 0.81 V vs. SCE in 0.05 M NaHCO3 at a scan rate of 50 mV s(-1) is a linear function of the concentration in a range 0.10006-0.654 mg cm(-3). It was also found that peak current density at 0.75 V vs. SCE at a scan rate of 2 mVs(-1), pulse amplitude of 25 mV and pulse time of 0.1 s exhibits linear dependence on the concentration of roxithromycin from 0.1006 to 0.476 mg cm(-3). Roxithromycin as a content of solid dosage form and urine was quantitatively determined and the obtained results were checked by HPLC.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "Electrochimica Acta", title = "Voltammetric and differential pulse determination of roxithromycin", pages = "52-47", number = "1", volume = "56", doi = "10.1016/j.electacta.2010.09.067" }
Drljević-Đurić, K., Jović, V. D., Lačnjevac, U., Avramov-Ivić, M., Petrović, S., Mijin, D.,& Đorđević, S. B.. (2010). Voltammetric and differential pulse determination of roxithromycin. in Electrochimica Acta Pergamon-Elsevier Science Ltd, Oxford., 56(1), 47-52. https://doi.org/10.1016/j.electacta.2010.09.067
Drljević-Đurić K, Jović VD, Lačnjevac U, Avramov-Ivić M, Petrović S, Mijin D, Đorđević SB. Voltammetric and differential pulse determination of roxithromycin. in Electrochimica Acta. 2010;56(1):47-52. doi:10.1016/j.electacta.2010.09.067 .
Drljević-Đurić, Katica, Jović, Vladimir D., Lačnjevac, Uroš, Avramov-Ivić, Milka, Petrović, Slobodan, Mijin, Dušan, Đorđević, S. B., "Voltammetric and differential pulse determination of roxithromycin" in Electrochimica Acta, 56, no. 1 (2010):47-52, https://doi.org/10.1016/j.electacta.2010.09.067 . .