TechnoRep - Faculty of Technology and Metallurgy Repository
University of Belgrade - Faculty of Technology and Metallurgy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   TechnoRep
  • Tehnološko-metalurški fakultet
  • Radovi istraživača / Researchers’ publications (TMF)
  • View Item
  •   TechnoRep
  • Tehnološko-metalurški fakultet
  • Radovi istraživača / Researchers’ publications (TMF)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles

Authorized Users Only
2011
Authors
Jokić, Bojan
Mitrić, Miodrag
Popović, Maja
Sima, L.
Petrescu, S. M.
Petrović, Rada
Janaćković, Đorđe
Article (Published version)
Metadata
Show full item record
Abstract
In this work, the influence of the morphology of hydroxyapatite particles on silicon substitution through hydrothermal synthesis performed under the same conditions was investigated. Spherical- and whisker-like hydroxyapatite particles were obtained starting from calcium-nitrate, sodium dihydrogen phosphate, disodium-ethylenediaminetetraacetic acid and urea (used only for the synthesis of whisker-like particles) dissolved in aqueous solutions. Silicon was introduced into the solution using tetraethylorthosilicate. X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy indicate that silicon doping induce different phase compositions and bioactivity of spherical- and whisker-like hydroxyapatite particles obtained under the same hydrothermal conditions. Silicon-substituted, spherical hydroxyapatites particles showed greater phase transformation to silicon-substituted alpha- calcium-phosphate compare...d with whiskers-like hydroxyapatite particles synthesized with the same amount of added silicon. Metabolic activity assay performed with SaOs2 osteosarcoma cells showed better biocompatibility of annealed biphasic spherical-like particles compared with annealed whiskerlike particles while dried spherical-like particles induce high cytotoxicity effect.

Source:
Journal of Materials Science-Materials in Medicine, 2011, 22, 10, 2175-2185
Publisher:
  • Springer, Dordrecht
Funding / projects:
  • Synthesis, processing and applications of nanostructured multifunctional materials with defined properties (RS-45019)

DOI: 10.1007/s10856-011-4412-6

ISSN: 0957-4530

PubMed: 21823030

WoS: 000295712600004

Scopus: 2-s2.0-84855166904
[ Google Scholar ]
11
9
URI
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1863
Collections
  • Radovi istraživača / Researchers’ publications (TMF)
Institution/Community
Tehnološko-metalurški fakultet
TY  - JOUR
AU  - Jokić, Bojan
AU  - Mitrić, Miodrag
AU  - Popović, Maja
AU  - Sima, L.
AU  - Petrescu, S. M.
AU  - Petrović, Rada
AU  - Janaćković, Đorđe
PY  - 2011
UR  - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/1863
AB  - In this work, the influence of the morphology of hydroxyapatite particles on silicon substitution through hydrothermal synthesis performed under the same conditions was investigated. Spherical- and whisker-like hydroxyapatite particles were obtained starting from calcium-nitrate, sodium dihydrogen phosphate, disodium-ethylenediaminetetraacetic acid and urea (used only for the synthesis of whisker-like particles) dissolved in aqueous solutions. Silicon was introduced into the solution using tetraethylorthosilicate. X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy indicate that silicon doping induce different phase compositions and bioactivity of spherical- and whisker-like hydroxyapatite particles obtained under the same hydrothermal conditions. Silicon-substituted, spherical hydroxyapatites particles showed greater phase transformation to silicon-substituted alpha- calcium-phosphate compared with whiskers-like hydroxyapatite particles synthesized with the same amount of added silicon. Metabolic activity assay performed with SaOs2 osteosarcoma cells showed better biocompatibility of annealed biphasic spherical-like particles compared with annealed whiskerlike particles while dried spherical-like particles induce high cytotoxicity effect.
PB  - Springer, Dordrecht
T2  - Journal of Materials Science-Materials in Medicine
T1  - The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles
EP  - 2185
IS  - 10
SP  - 2175
VL  - 22
DO  - 10.1007/s10856-011-4412-6
ER  - 
@article{
author = "Jokić, Bojan and Mitrić, Miodrag and Popović, Maja and Sima, L. and Petrescu, S. M. and Petrović, Rada and Janaćković, Đorđe",
year = "2011",
abstract = "In this work, the influence of the morphology of hydroxyapatite particles on silicon substitution through hydrothermal synthesis performed under the same conditions was investigated. Spherical- and whisker-like hydroxyapatite particles were obtained starting from calcium-nitrate, sodium dihydrogen phosphate, disodium-ethylenediaminetetraacetic acid and urea (used only for the synthesis of whisker-like particles) dissolved in aqueous solutions. Silicon was introduced into the solution using tetraethylorthosilicate. X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and transmission electron microscopy indicate that silicon doping induce different phase compositions and bioactivity of spherical- and whisker-like hydroxyapatite particles obtained under the same hydrothermal conditions. Silicon-substituted, spherical hydroxyapatites particles showed greater phase transformation to silicon-substituted alpha- calcium-phosphate compared with whiskers-like hydroxyapatite particles synthesized with the same amount of added silicon. Metabolic activity assay performed with SaOs2 osteosarcoma cells showed better biocompatibility of annealed biphasic spherical-like particles compared with annealed whiskerlike particles while dried spherical-like particles induce high cytotoxicity effect.",
publisher = "Springer, Dordrecht",
journal = "Journal of Materials Science-Materials in Medicine",
title = "The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles",
pages = "2185-2175",
number = "10",
volume = "22",
doi = "10.1007/s10856-011-4412-6"
}
Jokić, B., Mitrić, M., Popović, M., Sima, L., Petrescu, S. M., Petrović, R.,& Janaćković, Đ.. (2011). The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles. in Journal of Materials Science-Materials in Medicine
Springer, Dordrecht., 22(10), 2175-2185.
https://doi.org/10.1007/s10856-011-4412-6
Jokić B, Mitrić M, Popović M, Sima L, Petrescu SM, Petrović R, Janaćković Đ. The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles. in Journal of Materials Science-Materials in Medicine. 2011;22(10):2175-2185.
doi:10.1007/s10856-011-4412-6 .
Jokić, Bojan, Mitrić, Miodrag, Popović, Maja, Sima, L., Petrescu, S. M., Petrović, Rada, Janaćković, Đorđe, "The influence of silicon substitution on the properties of spherical- and whisker-like biphasic alpha-calcium-phosphate/hydroxyapatite particles" in Journal of Materials Science-Materials in Medicine, 22, no. 10 (2011):2175-2185,
https://doi.org/10.1007/s10856-011-4412-6 . .

DSpace software copyright © 2002-2015  DuraSpace
About TechnoRep | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About TechnoRep | Send Feedback

OpenAIRERCUB