Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage
Authorized Users Only
2013
Authors
Lezaja, MajaVeljović, Đorđe

Jokić, Bojan
Cvijović-Alagić, Ivana

Zrilić, Milorad

Miletić, Vesna

Article (Published version)

Metadata
Show full item recordAbstract
This study investigated the effect of shape, size, and surface modification of hydroxyapatite (HAP) fillers on the degree of conversion (DC) and mechanical properties of a model BisGMA/TEGDMA composite initially and after 4 weeks of storage. Ten percent of conventional glass fillers were replaced by HAP spheres (Sph), silicon-doped spheres (Sph(Si)), whiskers (Wh), silicon-doped whiskers (Wh(Si)), and nanosized HAP particles (Nano). Spheres were specifically structured agglomerates consisting of a central void and radially orientated primary particles, whereas whiskers were compact monocrystals. DC, Vickers hardness (HV), flexural strength (Fs), flexural modulus (Ef), compressive strength (Cs), and compressive modulus (Ec) were tested. There were no significant differences in the DC between all tested groups. HV decreased by 5.4-17% with the addition of HAP, while Fs increased by 13.9-29% except in Nano group (decrease by 13%). After storage, Sph and Sph(Si) groups showed similar HV, E...f, Cs and Ec and higher Fs than the control. The fracture mode of HAP spheres was through the central void whereas whiskers showed longitudinal delamination, transverse, and mixed fractures. HAP spheres with or without silicon- doping have a potential to be part of the filler content of dental composites.
Keywords:
hydroxyapatite / dental composites / mechanical properties / whiskers / fillers / methacrylateSource:
Journal of Biomedical Materials Research Part B-Applied Biomaterials, 2013, 101, 8, 1469-1476Publisher:
- Wiley-Blackwell, Hoboken
Funding / projects:
- Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)
- Synthesis, processing and applications of nanostructured multifunctional materials with defined properties (RS-45019)
DOI: 10.1002/jbm.b.32967
ISSN: 1552-4973
PubMed: 23744667
WoS: 000328450200016
Scopus: 2-s2.0-84886596446
Institution/Community
Tehnološko-metalurški fakultetTY - JOUR AU - Lezaja, Maja AU - Veljović, Đorđe AU - Jokić, Bojan AU - Cvijović-Alagić, Ivana AU - Zrilić, Milorad AU - Miletić, Vesna PY - 2013 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2471 AB - This study investigated the effect of shape, size, and surface modification of hydroxyapatite (HAP) fillers on the degree of conversion (DC) and mechanical properties of a model BisGMA/TEGDMA composite initially and after 4 weeks of storage. Ten percent of conventional glass fillers were replaced by HAP spheres (Sph), silicon-doped spheres (Sph(Si)), whiskers (Wh), silicon-doped whiskers (Wh(Si)), and nanosized HAP particles (Nano). Spheres were specifically structured agglomerates consisting of a central void and radially orientated primary particles, whereas whiskers were compact monocrystals. DC, Vickers hardness (HV), flexural strength (Fs), flexural modulus (Ef), compressive strength (Cs), and compressive modulus (Ec) were tested. There were no significant differences in the DC between all tested groups. HV decreased by 5.4-17% with the addition of HAP, while Fs increased by 13.9-29% except in Nano group (decrease by 13%). After storage, Sph and Sph(Si) groups showed similar HV, Ef, Cs and Ec and higher Fs than the control. The fracture mode of HAP spheres was through the central void whereas whiskers showed longitudinal delamination, transverse, and mixed fractures. HAP spheres with or without silicon- doping have a potential to be part of the filler content of dental composites. PB - Wiley-Blackwell, Hoboken T2 - Journal of Biomedical Materials Research Part B-Applied Biomaterials T1 - Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage EP - 1476 IS - 8 SP - 1469 VL - 101 DO - 10.1002/jbm.b.32967 ER -
@article{ author = "Lezaja, Maja and Veljović, Đorđe and Jokić, Bojan and Cvijović-Alagić, Ivana and Zrilić, Milorad and Miletić, Vesna", year = "2013", abstract = "This study investigated the effect of shape, size, and surface modification of hydroxyapatite (HAP) fillers on the degree of conversion (DC) and mechanical properties of a model BisGMA/TEGDMA composite initially and after 4 weeks of storage. Ten percent of conventional glass fillers were replaced by HAP spheres (Sph), silicon-doped spheres (Sph(Si)), whiskers (Wh), silicon-doped whiskers (Wh(Si)), and nanosized HAP particles (Nano). Spheres were specifically structured agglomerates consisting of a central void and radially orientated primary particles, whereas whiskers were compact monocrystals. DC, Vickers hardness (HV), flexural strength (Fs), flexural modulus (Ef), compressive strength (Cs), and compressive modulus (Ec) were tested. There were no significant differences in the DC between all tested groups. HV decreased by 5.4-17% with the addition of HAP, while Fs increased by 13.9-29% except in Nano group (decrease by 13%). After storage, Sph and Sph(Si) groups showed similar HV, Ef, Cs and Ec and higher Fs than the control. The fracture mode of HAP spheres was through the central void whereas whiskers showed longitudinal delamination, transverse, and mixed fractures. HAP spheres with or without silicon- doping have a potential to be part of the filler content of dental composites.", publisher = "Wiley-Blackwell, Hoboken", journal = "Journal of Biomedical Materials Research Part B-Applied Biomaterials", title = "Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage", pages = "1476-1469", number = "8", volume = "101", doi = "10.1002/jbm.b.32967" }
Lezaja, M., Veljović, Đ., Jokić, B., Cvijović-Alagić, I., Zrilić, M.,& Miletić, V.. (2013). Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage. in Journal of Biomedical Materials Research Part B-Applied Biomaterials Wiley-Blackwell, Hoboken., 101(8), 1469-1476. https://doi.org/10.1002/jbm.b.32967
Lezaja M, Veljović Đ, Jokić B, Cvijović-Alagić I, Zrilić M, Miletić V. Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage. in Journal of Biomedical Materials Research Part B-Applied Biomaterials. 2013;101(8):1469-1476. doi:10.1002/jbm.b.32967 .
Lezaja, Maja, Veljović, Đorđe, Jokić, Bojan, Cvijović-Alagić, Ivana, Zrilić, Milorad, Miletić, Vesna, "Effect of hydroxyapatite spheres, whiskers, and nanoparticles on mechanical properties of a model BisGMA/TEGDMA composite initially and after storage" in Journal of Biomedical Materials Research Part B-Applied Biomaterials, 101, no. 8 (2013):1469-1476, https://doi.org/10.1002/jbm.b.32967 . .