Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid
Само за регистроване кориснике
2015
Аутори
Janković, AnaEraković, Sanja
Mitrić, Miodrag
Matić, Ivana Z.
Juranić, Zorica D.
Tsui, Gary C. P.
Tang, C. Y.
Mišković-Stanković, Vesna
Rhee, Kyong Yop
Park, Soo Jin
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The hydroxyapatite/graphene (HAP/Gr) composite was electrodeposited on Ti using the electrophoretic deposition process to obtain uniform bioactive coating with improved mechanical strength and favorable corrosion stability in simulated body fluid (SBF). Incorporation of Gr was verified by Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis. The HAP/Gr composite coating exhibited reduced surface cracks, nearly double the hardness, and elastic modulus increased by almost 50% compared to pure HAP coating, as estimated by a nanoindentation test. The bioactive HAP/Gr composite coating provided a newly formed apatite layer in SBF with enhanced corrosion stability, as evidenced by electrochemical impedance spectroscopy. The thermal stability of the HAP/Gr coating was improved in comparison to the pure HAP coating, and the Ca/P ratio was closer to the stoichiometric value. No antibacterial activity against... Staphylococcus aureus or Escherichia coli could be verified. The HAP/Gr composite coating was classified as non-cytotoxic when tested against healthy peripheral blood mononuclear cells (PBMC).
Кључне речи:
Nano-structures / Mechanical properties / Corrosion / Surface analysisИзвор:
Journal of Alloys and Compounds, 2015, 624, 148-157Издавач:
- Elsevier Science Sa, Lausanne
Финансирање / пројекти:
- Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Education, Science and Technology [2013R1A1A2A10063466]
- Синтеза, развој технологија добијања и примена наноструктурних мултифункционалних материјала дефинисаних својстава (RS-45019)
DOI: 10.1016/j.jallcom.2014.11.078
ISSN: 0925-8388
WoS: 000346830300021
Scopus: 2-s2.0-84914129296
Колекције
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Janković, Ana AU - Eraković, Sanja AU - Mitrić, Miodrag AU - Matić, Ivana Z. AU - Juranić, Zorica D. AU - Tsui, Gary C. P. AU - Tang, C. Y. AU - Mišković-Stanković, Vesna AU - Rhee, Kyong Yop AU - Park, Soo Jin PY - 2015 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3006 AB - The hydroxyapatite/graphene (HAP/Gr) composite was electrodeposited on Ti using the electrophoretic deposition process to obtain uniform bioactive coating with improved mechanical strength and favorable corrosion stability in simulated body fluid (SBF). Incorporation of Gr was verified by Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis. The HAP/Gr composite coating exhibited reduced surface cracks, nearly double the hardness, and elastic modulus increased by almost 50% compared to pure HAP coating, as estimated by a nanoindentation test. The bioactive HAP/Gr composite coating provided a newly formed apatite layer in SBF with enhanced corrosion stability, as evidenced by electrochemical impedance spectroscopy. The thermal stability of the HAP/Gr coating was improved in comparison to the pure HAP coating, and the Ca/P ratio was closer to the stoichiometric value. No antibacterial activity against Staphylococcus aureus or Escherichia coli could be verified. The HAP/Gr composite coating was classified as non-cytotoxic when tested against healthy peripheral blood mononuclear cells (PBMC). PB - Elsevier Science Sa, Lausanne T2 - Journal of Alloys and Compounds T1 - Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid EP - 157 SP - 148 VL - 624 DO - 10.1016/j.jallcom.2014.11.078 ER -
@article{ author = "Janković, Ana and Eraković, Sanja and Mitrić, Miodrag and Matić, Ivana Z. and Juranić, Zorica D. and Tsui, Gary C. P. and Tang, C. Y. and Mišković-Stanković, Vesna and Rhee, Kyong Yop and Park, Soo Jin", year = "2015", abstract = "The hydroxyapatite/graphene (HAP/Gr) composite was electrodeposited on Ti using the electrophoretic deposition process to obtain uniform bioactive coating with improved mechanical strength and favorable corrosion stability in simulated body fluid (SBF). Incorporation of Gr was verified by Raman spectroscopy, X-ray diffraction, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis. The HAP/Gr composite coating exhibited reduced surface cracks, nearly double the hardness, and elastic modulus increased by almost 50% compared to pure HAP coating, as estimated by a nanoindentation test. The bioactive HAP/Gr composite coating provided a newly formed apatite layer in SBF with enhanced corrosion stability, as evidenced by electrochemical impedance spectroscopy. The thermal stability of the HAP/Gr coating was improved in comparison to the pure HAP coating, and the Ca/P ratio was closer to the stoichiometric value. No antibacterial activity against Staphylococcus aureus or Escherichia coli could be verified. The HAP/Gr composite coating was classified as non-cytotoxic when tested against healthy peripheral blood mononuclear cells (PBMC).", publisher = "Elsevier Science Sa, Lausanne", journal = "Journal of Alloys and Compounds", title = "Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid", pages = "157-148", volume = "624", doi = "10.1016/j.jallcom.2014.11.078" }
Janković, A., Eraković, S., Mitrić, M., Matić, I. Z., Juranić, Z. D., Tsui, G. C. P., Tang, C. Y., Mišković-Stanković, V., Rhee, K. Y.,& Park, S. J.. (2015). Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid. in Journal of Alloys and Compounds Elsevier Science Sa, Lausanne., 624, 148-157. https://doi.org/10.1016/j.jallcom.2014.11.078
Janković A, Eraković S, Mitrić M, Matić IZ, Juranić ZD, Tsui GCP, Tang CY, Mišković-Stanković V, Rhee KY, Park SJ. Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid. in Journal of Alloys and Compounds. 2015;624:148-157. doi:10.1016/j.jallcom.2014.11.078 .
Janković, Ana, Eraković, Sanja, Mitrić, Miodrag, Matić, Ivana Z., Juranić, Zorica D., Tsui, Gary C. P., Tang, C. Y., Mišković-Stanković, Vesna, Rhee, Kyong Yop, Park, Soo Jin, "Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid" in Journal of Alloys and Compounds, 624 (2015):148-157, https://doi.org/10.1016/j.jallcom.2014.11.078 . .