An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K
Authors
Ivaniš, Gorica
Tasić, Aleksandar Ž.
Radović, Ivona

Đorđević, Bojan D.
Šerbanović, Slobodan P.
Kijevčanin, Mirjana

Article (Published version)
Metadata
Show full item recordAbstract
In this work, an apparatus for density measurements in the compressed liquid regions is presented. This installation is based on the use of a DMA HP density measuring cell and a DMA 5000 densimeter (both instruments are products of Anton Paar, Gratz, Austria). Calibration of the DMA HP cell was performed by applying the classical method in which a vacuum, water and n-decane were recommended to be used as calibration fluids. To test the capabilities of the set-up, the densities of n-hexane, toluene and dichloromethane were measured in the temperature interval 288.15 to 413.15 K and the pressure range 0.1-60 MPa. The obtained results were compared with the corresponding values found in the literature. Depending on the literature selected for comparison (the temperature and pressure ranges available), the average absolute percentage deviations were for n-hexane, 0.03-0.10 %; for toluene, 0.04-0.08 % and for dichloromethane, 0.02-0.03 %. A deeper insight into the results of this work showe...d that most of them were in good agreement with the literature values; higher discrepancies were evidenced in the vicinity of the ends of the temperature and pressure ranges.
Keywords:
high pressure / elevated temperature / density / n-hexane / toluene / dichloromethaneSource:
Journal of the Serbian Chemical Society, 2015, 80, 8, 1073-S277Publisher:
- Srpsko hemijsko društvo, Beograd
Funding / projects:
- New industrial and environmental application of chemical thermodynamics to the development of the chemical processes with multiphase and multicomponent systems (RS-172063)
- Faculty of Technology and Metallurgy, University of Belgrade
DOI: 10.2298/JSC141127026I
ISSN: 0352-5139
WoS: 000364205200009
Scopus: 2-s2.0-84946087386
Institution/Community
Tehnološko-metalurški fakultetTY - JOUR AU - Ivaniš, Gorica AU - Tasić, Aleksandar Ž. AU - Radović, Ivona AU - Đorđević, Bojan D. AU - Šerbanović, Slobodan P. AU - Kijevčanin, Mirjana PY - 2015 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3090 AB - In this work, an apparatus for density measurements in the compressed liquid regions is presented. This installation is based on the use of a DMA HP density measuring cell and a DMA 5000 densimeter (both instruments are products of Anton Paar, Gratz, Austria). Calibration of the DMA HP cell was performed by applying the classical method in which a vacuum, water and n-decane were recommended to be used as calibration fluids. To test the capabilities of the set-up, the densities of n-hexane, toluene and dichloromethane were measured in the temperature interval 288.15 to 413.15 K and the pressure range 0.1-60 MPa. The obtained results were compared with the corresponding values found in the literature. Depending on the literature selected for comparison (the temperature and pressure ranges available), the average absolute percentage deviations were for n-hexane, 0.03-0.10 %; for toluene, 0.04-0.08 % and for dichloromethane, 0.02-0.03 %. A deeper insight into the results of this work showed that most of them were in good agreement with the literature values; higher discrepancies were evidenced in the vicinity of the ends of the temperature and pressure ranges. PB - Srpsko hemijsko društvo, Beograd T2 - Journal of the Serbian Chemical Society T1 - An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K EP - S277 IS - 8 SP - 1073 VL - 80 DO - 10.2298/JSC141127026I ER -
@article{ author = "Ivaniš, Gorica and Tasić, Aleksandar Ž. and Radović, Ivona and Đorđević, Bojan D. and Šerbanović, Slobodan P. and Kijevčanin, Mirjana", year = "2015", abstract = "In this work, an apparatus for density measurements in the compressed liquid regions is presented. This installation is based on the use of a DMA HP density measuring cell and a DMA 5000 densimeter (both instruments are products of Anton Paar, Gratz, Austria). Calibration of the DMA HP cell was performed by applying the classical method in which a vacuum, water and n-decane were recommended to be used as calibration fluids. To test the capabilities of the set-up, the densities of n-hexane, toluene and dichloromethane were measured in the temperature interval 288.15 to 413.15 K and the pressure range 0.1-60 MPa. The obtained results were compared with the corresponding values found in the literature. Depending on the literature selected for comparison (the temperature and pressure ranges available), the average absolute percentage deviations were for n-hexane, 0.03-0.10 %; for toluene, 0.04-0.08 % and for dichloromethane, 0.02-0.03 %. A deeper insight into the results of this work showed that most of them were in good agreement with the literature values; higher discrepancies were evidenced in the vicinity of the ends of the temperature and pressure ranges.", publisher = "Srpsko hemijsko društvo, Beograd", journal = "Journal of the Serbian Chemical Society", title = "An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K", pages = "S277-1073", number = "8", volume = "80", doi = "10.2298/JSC141127026I" }
Ivaniš, G., Tasić, A. Ž., Radović, I., Đorđević, B. D., Šerbanović, S. P.,& Kijevčanin, M.. (2015). An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K. in Journal of the Serbian Chemical Society Srpsko hemijsko društvo, Beograd., 80(8), 1073-S277. https://doi.org/10.2298/JSC141127026I
Ivaniš G, Tasić AŽ, Radović I, Đorđević BD, Šerbanović SP, Kijevčanin M. An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K. in Journal of the Serbian Chemical Society. 2015;80(8):1073-S277. doi:10.2298/JSC141127026I .
Ivaniš, Gorica, Tasić, Aleksandar Ž., Radović, Ivona, Đorđević, Bojan D., Šerbanović, Slobodan P., Kijevčanin, Mirjana, "An apparatus proposed for density measurements in compressed liquid regions at pressures of 0.1-60 MPa and temperatures of 288.15-413.15 K" in Journal of the Serbian Chemical Society, 80, no. 8 (2015):1073-S277, https://doi.org/10.2298/JSC141127026I . .