Приказ основних података о документу

Lomovi kondenzatorskih cevi od mesinga

dc.creatorBobić, Biljana
dc.creatorJegdić, Bore
dc.creatorJugović, Branimir
dc.creatorStevanović, Jasmina
dc.creatorGligorijević, Bojan
dc.creatorMurariu, Alin
dc.date.accessioned2021-03-10T12:57:28Z
dc.date.available2021-03-10T12:57:28Z
dc.date.issued2016
dc.identifier.issn1451-3749
dc.identifier.urihttp://TechnoRep.tmf.bg.ac.rs/handle/123456789/3180
dc.description.abstractCauses of failure of brass condenser tubes (CuZn28Sn1) in a thermal power plant in Serbia are analysed. Results of testing by Fourier transformed infrared spectroscopy (FTIR) have indicated the presence of ammonia and nitro- gen compounds on fracture surfaces and on the inner surface of the tubes. These compounds are specific agents that cause stress corrosion cracking (SCC) in brass. Analy- sis of fracture surfaces using scanning electron microscopy (SEM) has shown the brittle transgranular fracture due to the occurrence of SCC. The resistance of brass condenser tubes to other types of corrosion, such as erosion, general and selective corrosion (dezincification) is also considered. Some procedures are proposed to reduce the risk of SCC in the brass condenser tubes.en
dc.description.abstractAnalizirani su uzroci pojave loma kondenzatorskih cevi od mesinga CuZn28Sn1 u jednoj termoelektrani u Srbiji. Rezultati ispitivanja metodom Furijeove transformisane infracrvene spektroskopije (FTIR) ukazuju na prisustvo amonijačnih i azotnih jedinjenja na površini loma i na unutrašnjoj površini cevi. Ta jedinjenja su specifični agensi za pojavu naponske korozije mesinga. Analiza površine loma primenom skening elektronske mikroskopije (SEM) pokazala je prisustvo krtog transkistalnog loma nastalog usled pojave naponske korozije. Razmatrana je otpornost cevi od mesinga CuZn28Sn1 prema drugim vidovima koro- zije, kao što su eroziona, opšta i selektivna korozija (decin- kacija). Predloženi su postupci za smanjenje rizika od pojave naponske korozije u kondenzatorskim cevima.sr
dc.publisherInstitut za ispitivanje materijala, Beograd
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/34028/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/35021/RS//
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceStructural Integrity and Life
dc.subjectcondenser tubesen
dc.subjectbrassen
dc.subjectstress corrosion crackingen
dc.subjectdezincificationen
dc.titleFailures of Brass Condenser Tubesen
dc.titleLomovi kondenzatorskih cevi od mesingasr
dc.typearticle
dc.rights.licenseBY-NC-ND
dc.citation.epage23
dc.citation.issue1
dc.citation.other16(1): 19-23
dc.citation.rankM24
dc.citation.spage19
dc.citation.volume16
dc.identifier.fulltexthttp://TechnoRep.tmf.bg.ac.rs/bitstream/id/1153/3177.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_technorep_3180
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу