An investigation of tebuconazole degradation using a gold electrode

2016
Аутори
Lović, Jelena
Mijin, Dušan

Jovanović, Mica B.
Glavaski, Olivera
Zeremski, Tijana

Petrović, Slobodan
Avramov-Ivić, Milka

Чланак у часопису (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
Tebuconazole, a pesticide that presents risks for ecosystems, groundwater and human health, was degraded on a gold electrode as the catalyst in 0.05 M NaHCO3 using cyclic voltammetry (CV). First, tebuconazole was characterized on the gold electrode using CV and square wave voltammetry (SWV). The gold electrode, being highly sensitive, provided linear relationships (currents vs. concentrations) in the range: (0.076-0.76 mu mol dm(-3)). Based on the CV measurements, the investigated process is irreversible and diffusion controlled. The observed catalytic role of the Au electrode in the oxidation of tebuconazole and the data obtained from CV and SWV provided the experimental conditions for the degradation of tebuconazole. The degradation was performed by continuous cycling followed by gas chromatography mass spectroscopy (GC MS) analysis. This enabled the catalytic elimination of tebuconazole for 60 min, which promoted the use of a gold electrode as the catalyst for the degradation of env...ironmental pollutants. The scheme of the possible mechanism of tebuconazole degradation is given.
Кључне речи:
Catalytic degradation / Tebuconazole / Gold electrode / CV voltammetry / GC-MS analysisИзвор:
Comptes Rendus Chimie, 2016, 19, 5, 639-645Издавач:
- Elsevier France-Editions Scientifiques Medicales Elsevier, Paris
Финансирање / пројекти:
- Проучавање синтезе, структуре и активности органских једињења природног и синтетског порекла (RS-172013)
- Нов приступ дизајнирању материјала за конверзију и складиштење енергије (RS-172060)
DOI: 10.1016/j.crci.2016.01.014
ISSN: 1631-0748
WoS: 000385785100012
Scopus: 2-s2.0-84959263685
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Lović, Jelena AU - Mijin, Dušan AU - Jovanović, Mica B. AU - Glavaski, Olivera AU - Zeremski, Tijana AU - Petrović, Slobodan AU - Avramov-Ivić, Milka PY - 2016 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3350 AB - Tebuconazole, a pesticide that presents risks for ecosystems, groundwater and human health, was degraded on a gold electrode as the catalyst in 0.05 M NaHCO3 using cyclic voltammetry (CV). First, tebuconazole was characterized on the gold electrode using CV and square wave voltammetry (SWV). The gold electrode, being highly sensitive, provided linear relationships (currents vs. concentrations) in the range: (0.076-0.76 mu mol dm(-3)). Based on the CV measurements, the investigated process is irreversible and diffusion controlled. The observed catalytic role of the Au electrode in the oxidation of tebuconazole and the data obtained from CV and SWV provided the experimental conditions for the degradation of tebuconazole. The degradation was performed by continuous cycling followed by gas chromatography mass spectroscopy (GC MS) analysis. This enabled the catalytic elimination of tebuconazole for 60 min, which promoted the use of a gold electrode as the catalyst for the degradation of environmental pollutants. The scheme of the possible mechanism of tebuconazole degradation is given. PB - Elsevier France-Editions Scientifiques Medicales Elsevier, Paris T2 - Comptes Rendus Chimie T1 - An investigation of tebuconazole degradation using a gold electrode EP - 645 IS - 5 SP - 639 VL - 19 DO - 10.1016/j.crci.2016.01.014 ER -
@article{ author = "Lović, Jelena and Mijin, Dušan and Jovanović, Mica B. and Glavaski, Olivera and Zeremski, Tijana and Petrović, Slobodan and Avramov-Ivić, Milka", year = "2016", abstract = "Tebuconazole, a pesticide that presents risks for ecosystems, groundwater and human health, was degraded on a gold electrode as the catalyst in 0.05 M NaHCO3 using cyclic voltammetry (CV). First, tebuconazole was characterized on the gold electrode using CV and square wave voltammetry (SWV). The gold electrode, being highly sensitive, provided linear relationships (currents vs. concentrations) in the range: (0.076-0.76 mu mol dm(-3)). Based on the CV measurements, the investigated process is irreversible and diffusion controlled. The observed catalytic role of the Au electrode in the oxidation of tebuconazole and the data obtained from CV and SWV provided the experimental conditions for the degradation of tebuconazole. The degradation was performed by continuous cycling followed by gas chromatography mass spectroscopy (GC MS) analysis. This enabled the catalytic elimination of tebuconazole for 60 min, which promoted the use of a gold electrode as the catalyst for the degradation of environmental pollutants. The scheme of the possible mechanism of tebuconazole degradation is given.", publisher = "Elsevier France-Editions Scientifiques Medicales Elsevier, Paris", journal = "Comptes Rendus Chimie", title = "An investigation of tebuconazole degradation using a gold electrode", pages = "645-639", number = "5", volume = "19", doi = "10.1016/j.crci.2016.01.014" }
Lović, J., Mijin, D., Jovanović, M. B., Glavaski, O., Zeremski, T., Petrović, S.,& Avramov-Ivić, M.. (2016). An investigation of tebuconazole degradation using a gold electrode. in Comptes Rendus Chimie Elsevier France-Editions Scientifiques Medicales Elsevier, Paris., 19(5), 639-645. https://doi.org/10.1016/j.crci.2016.01.014
Lović J, Mijin D, Jovanović MB, Glavaski O, Zeremski T, Petrović S, Avramov-Ivić M. An investigation of tebuconazole degradation using a gold electrode. in Comptes Rendus Chimie. 2016;19(5):639-645. doi:10.1016/j.crci.2016.01.014 .
Lović, Jelena, Mijin, Dušan, Jovanović, Mica B., Glavaski, Olivera, Zeremski, Tijana, Petrović, Slobodan, Avramov-Ivić, Milka, "An investigation of tebuconazole degradation using a gold electrode" in Comptes Rendus Chimie, 19, no. 5 (2016):639-645, https://doi.org/10.1016/j.crci.2016.01.014 . .