Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation
Authorized Users Only
2019
Authors
Avramov-Ivić, Milka
Lović, Jelena

Stevanović, Sanja

Nikolić, Nebojša

Trišović, Nemanja

Lađarević, Jelena

Vuković, Dragan

Drmanić, Saša

Mladenović, Aleksandar R.

Jadranin, Milka

Petrović, Slobodan
Mijin, Dušan

Article (Published version)

Metadata
Show full item recordAbstract
Esomeprazole is the most effective of the proton-pump inhibitors for the acid-related diseases and at first was examined for the electroanalytical purposes. The drug standard and as a content of injection powder was investigated by cyclic voltammetry (CV) and quantitatively determined using square wave voltammetry (SWV) via its electrooxidation at Au electrode in 0.05 M NaHCO3. SWV showed a linear dependency of the anodic peak currents vs. esomeprazole standard concentrations in the range from 3.0 to 500 mu g mL(-1) with the values of limit of detection (LOD) and limit of quantification (LOQ): 1.4 and 4.6 mu g mL(-1), respectively. Using the constructed and validated calibration curve, the values of unknown esomeprazole concentrations in injection powder and in human serum spiked with standard were determined. Before the electrochemical oxidation, it was shown by atomic force microscopy (AFM) that the small esomeprazole islands formed inside holes were visible and their diameter was ab...out 200 nm attributed to physico-chemical characteristics of esomeprazole. After the electrochemical oxidation, the morphology of esomeprazole standard on Au surface was completely changed and composed of spherical particles in a diameter between 200 and 600 nm. With esomeprazole suspended in human serum, the process of crystallization partly occurred in the form of spherical grains with the average size of these grains was about 4 gm. The analysis at the macro level done by the optical microscopy (OM) confirmed this opinion. The study of esomeprazole degradation showed that at Au electrode, after 3 h of cycling, a neglectable amount of the esomeprazole was changed. Using IrOx electrode under directed stress conditions, its almost complete degradation was realized after 3 h confirmed by high performance liquid chromatography (HPLC). Total organic carbon (TOC) analysis showed that 95% of esomeprazole was mineralized. The HPLC and Liquid chromatography-mass spectrometry (LC-MS) study revealed the formation of 4-hydroxy omeprazole sulphide, 4-hydroxy omeprazole sulphone, esomeprazole sulphone and methylated esomeprazole.
Keywords:
Esomeprazole / SWV determination at Au / Au surface analysis by AFM and OM / Degradation at IrOx / HPLC / LC-MSSource:
Journal of Electroanalytical Chemistry, 2019, 848Publisher:
- Elsevier Science Sa, Lausanne
Funding / projects:
- Study of the Synthesis, Structure and Activity of Natural and Synthetic Organic Compounds (RS-172013)
- New approach in designing materials for energy conversion and energy storage systems (RS-172060)
DOI: 10.1016/j.jelechem.2019.113303
ISSN: 1572-6657
WoS: 000504505400031
Scopus: 2-s2.0-85069593343
Institution/Community
Tehnološko-metalurški fakultetTY - JOUR AU - Avramov-Ivić, Milka AU - Lović, Jelena AU - Stevanović, Sanja AU - Nikolić, Nebojša AU - Trišović, Nemanja AU - Lađarević, Jelena AU - Vuković, Dragan AU - Drmanić, Saša AU - Mladenović, Aleksandar R. AU - Jadranin, Milka AU - Petrović, Slobodan AU - Mijin, Dušan PY - 2019 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/4306 AB - Esomeprazole is the most effective of the proton-pump inhibitors for the acid-related diseases and at first was examined for the electroanalytical purposes. The drug standard and as a content of injection powder was investigated by cyclic voltammetry (CV) and quantitatively determined using square wave voltammetry (SWV) via its electrooxidation at Au electrode in 0.05 M NaHCO3. SWV showed a linear dependency of the anodic peak currents vs. esomeprazole standard concentrations in the range from 3.0 to 500 mu g mL(-1) with the values of limit of detection (LOD) and limit of quantification (LOQ): 1.4 and 4.6 mu g mL(-1), respectively. Using the constructed and validated calibration curve, the values of unknown esomeprazole concentrations in injection powder and in human serum spiked with standard were determined. Before the electrochemical oxidation, it was shown by atomic force microscopy (AFM) that the small esomeprazole islands formed inside holes were visible and their diameter was about 200 nm attributed to physico-chemical characteristics of esomeprazole. After the electrochemical oxidation, the morphology of esomeprazole standard on Au surface was completely changed and composed of spherical particles in a diameter between 200 and 600 nm. With esomeprazole suspended in human serum, the process of crystallization partly occurred in the form of spherical grains with the average size of these grains was about 4 gm. The analysis at the macro level done by the optical microscopy (OM) confirmed this opinion. The study of esomeprazole degradation showed that at Au electrode, after 3 h of cycling, a neglectable amount of the esomeprazole was changed. Using IrOx electrode under directed stress conditions, its almost complete degradation was realized after 3 h confirmed by high performance liquid chromatography (HPLC). Total organic carbon (TOC) analysis showed that 95% of esomeprazole was mineralized. The HPLC and Liquid chromatography-mass spectrometry (LC-MS) study revealed the formation of 4-hydroxy omeprazole sulphide, 4-hydroxy omeprazole sulphone, esomeprazole sulphone and methylated esomeprazole. PB - Elsevier Science Sa, Lausanne T2 - Journal of Electroanalytical Chemistry T1 - Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation VL - 848 DO - 10.1016/j.jelechem.2019.113303 ER -
@article{ author = "Avramov-Ivić, Milka and Lović, Jelena and Stevanović, Sanja and Nikolić, Nebojša and Trišović, Nemanja and Lađarević, Jelena and Vuković, Dragan and Drmanić, Saša and Mladenović, Aleksandar R. and Jadranin, Milka and Petrović, Slobodan and Mijin, Dušan", year = "2019", abstract = "Esomeprazole is the most effective of the proton-pump inhibitors for the acid-related diseases and at first was examined for the electroanalytical purposes. The drug standard and as a content of injection powder was investigated by cyclic voltammetry (CV) and quantitatively determined using square wave voltammetry (SWV) via its electrooxidation at Au electrode in 0.05 M NaHCO3. SWV showed a linear dependency of the anodic peak currents vs. esomeprazole standard concentrations in the range from 3.0 to 500 mu g mL(-1) with the values of limit of detection (LOD) and limit of quantification (LOQ): 1.4 and 4.6 mu g mL(-1), respectively. Using the constructed and validated calibration curve, the values of unknown esomeprazole concentrations in injection powder and in human serum spiked with standard were determined. Before the electrochemical oxidation, it was shown by atomic force microscopy (AFM) that the small esomeprazole islands formed inside holes were visible and their diameter was about 200 nm attributed to physico-chemical characteristics of esomeprazole. After the electrochemical oxidation, the morphology of esomeprazole standard on Au surface was completely changed and composed of spherical particles in a diameter between 200 and 600 nm. With esomeprazole suspended in human serum, the process of crystallization partly occurred in the form of spherical grains with the average size of these grains was about 4 gm. The analysis at the macro level done by the optical microscopy (OM) confirmed this opinion. The study of esomeprazole degradation showed that at Au electrode, after 3 h of cycling, a neglectable amount of the esomeprazole was changed. Using IrOx electrode under directed stress conditions, its almost complete degradation was realized after 3 h confirmed by high performance liquid chromatography (HPLC). Total organic carbon (TOC) analysis showed that 95% of esomeprazole was mineralized. The HPLC and Liquid chromatography-mass spectrometry (LC-MS) study revealed the formation of 4-hydroxy omeprazole sulphide, 4-hydroxy omeprazole sulphone, esomeprazole sulphone and methylated esomeprazole.", publisher = "Elsevier Science Sa, Lausanne", journal = "Journal of Electroanalytical Chemistry", title = "Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation", volume = "848", doi = "10.1016/j.jelechem.2019.113303" }
Avramov-Ivić, M., Lović, J., Stevanović, S., Nikolić, N., Trišović, N., Lađarević, J., Vuković, D., Drmanić, S., Mladenović, A. R., Jadranin, M., Petrović, S.,& Mijin, D.. (2019). Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation. in Journal of Electroanalytical Chemistry Elsevier Science Sa, Lausanne., 848. https://doi.org/10.1016/j.jelechem.2019.113303
Avramov-Ivić M, Lović J, Stevanović S, Nikolić N, Trišović N, Lađarević J, Vuković D, Drmanić S, Mladenović AR, Jadranin M, Petrović S, Mijin D. Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation. in Journal of Electroanalytical Chemistry. 2019;848. doi:10.1016/j.jelechem.2019.113303 .
Avramov-Ivić, Milka, Lović, Jelena, Stevanović, Sanja, Nikolić, Nebojša, Trišović, Nemanja, Lađarević, Jelena, Vuković, Dragan, Drmanić, Saša, Mladenović, Aleksandar R., Jadranin, Milka, Petrović, Slobodan, Mijin, Dušan, "Electrochemical behavior of esomeprazole: Its determination at Au electrode as standard and in injection powder combined with the study of its degradation" in Journal of Electroanalytical Chemistry, 848 (2019), https://doi.org/10.1016/j.jelechem.2019.113303 . .