Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions
Само за регистроване кориснике
2000
Аутори
Korenman, Y.I.Kumchenko, T.A.
Strashilina, N.Y.
Aristov, I.V.
Rajakovic, LJ.V.
Antonovic, D.G.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The optimal conditions have been found for aniline sorption on a film of poly(ethylene glycol succinate) by the piezoelectric quartz crystal microbalance method using bulk acoustic wave sensors based on AT-cut quartz crystals under static and dynamic conditions. The dependence of the analytical signal of the quartz crystal resonator on the modifier film mass, the volumetric flow rate of the carrier gas (air), and the sorption temperature has been investigated.
Извор:
Journal of Analytical Chemistry, 2000, 55, 9, 893-898Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Korenman, Y.I. AU - Kumchenko, T.A. AU - Strashilina, N.Y. AU - Aristov, I.V. AU - Rajakovic, LJ.V. AU - Antonovic, D.G. PY - 2000 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5336 AB - The optimal conditions have been found for aniline sorption on a film of poly(ethylene glycol succinate) by the piezoelectric quartz crystal microbalance method using bulk acoustic wave sensors based on AT-cut quartz crystals under static and dynamic conditions. The dependence of the analytical signal of the quartz crystal resonator on the modifier film mass, the volumetric flow rate of the carrier gas (air), and the sorption temperature has been investigated. T2 - Journal of Analytical Chemistry T1 - Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions EP - 898 IS - 9 SP - 893 VL - 55 DO - 10.1007/BF02757857 ER -
@article{ author = "Korenman, Y.I. and Kumchenko, T.A. and Strashilina, N.Y. and Aristov, I.V. and Rajakovic, LJ.V. and Antonovic, D.G.", year = "2000", abstract = "The optimal conditions have been found for aniline sorption on a film of poly(ethylene glycol succinate) by the piezoelectric quartz crystal microbalance method using bulk acoustic wave sensors based on AT-cut quartz crystals under static and dynamic conditions. The dependence of the analytical signal of the quartz crystal resonator on the modifier film mass, the volumetric flow rate of the carrier gas (air), and the sorption temperature has been investigated.", journal = "Journal of Analytical Chemistry", title = "Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions", pages = "898-893", number = "9", volume = "55", doi = "10.1007/BF02757857" }
Korenman, Y.I., Kumchenko, T.A., Strashilina, N.Y., Aristov, I.V., Rajakovic, LJ.V.,& Antonovic, D.G.. (2000). Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions. in Journal of Analytical Chemistry, 55(9), 893-898. https://doi.org/10.1007/BF02757857
Korenman Y, Kumchenko T, Strashilina N, Aristov I, Rajakovic L, Antonovic D. Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions. in Journal of Analytical Chemistry. 2000;55(9):893-898. doi:10.1007/BF02757857 .
Korenman, Y.I., Kumchenko, T.A., Strashilina, N.Y., Aristov, I.V., Rajakovic, LJ.V., Antonovic, D.G., "Detecting aniline in air in systems based on piezoelectric quartz crystal resonators modified with poly(ethylene glycol succinate) under static and dynamic conditions" in Journal of Analytical Chemistry, 55, no. 9 (2000):893-898, https://doi.org/10.1007/BF02757857 . .