Приказ основних података о документу

dc.creatorManojlović, Dragica
dc.creatorRadisić, Marina
dc.creatorVasiljević, Tatjana
dc.creatorŽivković, Slavoljub
dc.creatorLaušević, Mila
dc.creatorMiletić, Vesna
dc.date.accessioned2020-07-02T12:32:32Z
dc.date.accessioned2023-01-23T14:13:40Z
dc.date.available2020-07-02T12:32:32Z
dc.date.available2023-01-23T14:13:40Z
dc.date.issued2011
dc.identifier.issn0109-5641
dc.identifier.urihttp://TechnoRep.tmf.bg.ac.rs/handle/123456789/5640
dc.description.abstractObjectives. To study monomer elution from four resin-based composites (RBCs) cured with different light sources. Methods. Twenty-eight premolars were randomly allocated to four groups. Standardized cavities were prepared and restored with a nanohybrid (Filtek Supreme XT or Tetric EvoCeram), an ormocer (Admira) or a microhybrid RBC (Filtek Z250) which served as control. Buccal restorations were cured with a halogen and oral restorations with an LED light-curing unit. Elution of diurethane dimethacrylate (UDMA), Bisphenol A diglycidylether methacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) and 2-hydroxyethyl methacrylate (HEMA) was analyzed using high-performance liquid chromatography (HPLC) 1h to 28 days post-immersion in 75% ethanol. Data were analyzed using multivariate and repeated measures analysis of variance (alpha = 0.05). Results. The greatest elution of UDMA and BisGMA occurred from Tetric EvoCeram and the least from Filtek Z250 (p lt 0.05). LED and halogen light-curing units gave similar results for all RBCs (p > 0.05) except Tetric EvoCeram which showed greater elution for the LED unit (p lt 0.05). TEGDMA was below the limit of quantification. HEMA eluted in similar concentrations from Filtek Supreme and Tetric EvoCeram (p > 0.05). Significance. : The two nanohybrid RBCs eluted more cross-linking monomers than the ormocer and the control microhybrid RBC. Continuous elution over 28 days indicates that RBCs act as a chronic source of monomers in clinical conditions. Light source may affect monomer elution since differences were found for one out of four RBCs. Mathematical models for elution kinetics of UDMA and BisGMA indicated two elution mechanisms.en
dc.publisherElsevier Sci Ltd, Oxford
dc.relationinfo:eu-repo/grantAgreement/MESTD/MPN2006-2010/142002/RS//
dc.rightsrestrictedAccess
dc.sourceDental Materials
dc.subjectResin based compositesen
dc.subjectMonomersen
dc.subjectMethacrylatesen
dc.subjectElutionen
dc.subjectHPLCen
dc.subjectLight curing unitsen
dc.subjectNanohybriden
dc.subjectOrmoceren
dc.titleMonomer elution from nanohybrid and ormocer-based composites cured with different light sourcesen
dc.typearticle
dc.rights.licenseARR
dc.citation.epage378
dc.citation.issue4
dc.citation.other27(4): 371-378
dc.citation.rankaM21
dc.citation.spage371
dc.citation.volume27
dc.identifier.doi10.1016/j.dental.2010.11.017
dc.identifier.pmid21168907
dc.identifier.scopus2-s2.0-79952280207
dc.identifier.wos000287916000011
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу