Abstract
High density polyethylene (HDPE) has been modified by Ag+ and Au+ ion implantation with the energy of 60 and 200 keV, respectively. The doses of implanted silver and gold ions were as follows: 1 x 10(15), 5 x 10(15) and 1 x 10(16) ions/cm(2). The surface topography was observed using atomic force microscopy (AFM), while the surface composition changes were detected using phase imaging AFM. Phase analysis of AFM images shows that both physical and chemical changes occur on the surface of HDPE and that these changes depend on the nature of implanted ions and on the implantation dose. Silver ion implantation causes a higher degree of chemical changes, while the implantation of gold ions causes a higher degree of physical changes. Breakpoints were observed for the implantation doses of 0.6 x 10(15) and 4.4 x 10(15) ions/cm(2) for silver and gold ions, respectively. Physical changes are confirmed by the analysis of mean square roughness and power spectral density slopes as functions of the ...implantation dose. The position and half-width of peaks in histograms of phase AFM images confirmed the changes in surface composition.
Keywords:
Polyethylene / Silver / Gold / Ion implantation / Phase AFMSource:
Surface and Coatings Technology, 2012, 206, 19-20, 4242-4248Publisher:
- Elsevier
Funding / projects:
DOI: 10.1016/j.surfcoat.2012.04.032
ISSN: 0257-8972
WoS: 000305662400058
Scopus: 2-s2.0-84861459599
Institution/Community
Tehnološko-metalurški fakultetTY - JOUR AU - Nenadović, Miloš AU - Potočnik, Jelena AU - Ristic, M. AU - Štrbac, Svetlana AU - Rakočević, Zlatko Lj. PY - 2012 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5741 AB - High density polyethylene (HDPE) has been modified by Ag+ and Au+ ion implantation with the energy of 60 and 200 keV, respectively. The doses of implanted silver and gold ions were as follows: 1 x 10(15), 5 x 10(15) and 1 x 10(16) ions/cm(2). The surface topography was observed using atomic force microscopy (AFM), while the surface composition changes were detected using phase imaging AFM. Phase analysis of AFM images shows that both physical and chemical changes occur on the surface of HDPE and that these changes depend on the nature of implanted ions and on the implantation dose. Silver ion implantation causes a higher degree of chemical changes, while the implantation of gold ions causes a higher degree of physical changes. Breakpoints were observed for the implantation doses of 0.6 x 10(15) and 4.4 x 10(15) ions/cm(2) for silver and gold ions, respectively. Physical changes are confirmed by the analysis of mean square roughness and power spectral density slopes as functions of the implantation dose. The position and half-width of peaks in histograms of phase AFM images confirmed the changes in surface composition. PB - Elsevier T2 - Surface and Coatings Technology T1 - Surface modification of polyethylene by Ag+ and Au+ ion implantation observed by phase imaging atomic force microscopy EP - 4248 IS - 19-20 SP - 4242 VL - 206 DO - 10.1016/j.surfcoat.2012.04.032 ER -
@article{ author = "Nenadović, Miloš and Potočnik, Jelena and Ristic, M. and Štrbac, Svetlana and Rakočević, Zlatko Lj.", year = "2012", abstract = "High density polyethylene (HDPE) has been modified by Ag+ and Au+ ion implantation with the energy of 60 and 200 keV, respectively. The doses of implanted silver and gold ions were as follows: 1 x 10(15), 5 x 10(15) and 1 x 10(16) ions/cm(2). The surface topography was observed using atomic force microscopy (AFM), while the surface composition changes were detected using phase imaging AFM. Phase analysis of AFM images shows that both physical and chemical changes occur on the surface of HDPE and that these changes depend on the nature of implanted ions and on the implantation dose. Silver ion implantation causes a higher degree of chemical changes, while the implantation of gold ions causes a higher degree of physical changes. Breakpoints were observed for the implantation doses of 0.6 x 10(15) and 4.4 x 10(15) ions/cm(2) for silver and gold ions, respectively. Physical changes are confirmed by the analysis of mean square roughness and power spectral density slopes as functions of the implantation dose. The position and half-width of peaks in histograms of phase AFM images confirmed the changes in surface composition.", publisher = "Elsevier", journal = "Surface and Coatings Technology", title = "Surface modification of polyethylene by Ag+ and Au+ ion implantation observed by phase imaging atomic force microscopy", pages = "4248-4242", number = "19-20", volume = "206", doi = "10.1016/j.surfcoat.2012.04.032" }
Nenadović, M., Potočnik, J., Ristic, M., Štrbac, S.,& Rakočević, Z. Lj.. (2012). Surface modification of polyethylene by Ag+ and Au+ ion implantation observed by phase imaging atomic force microscopy. in Surface and Coatings Technology Elsevier., 206(19-20), 4242-4248. https://doi.org/10.1016/j.surfcoat.2012.04.032
Nenadović M, Potočnik J, Ristic M, Štrbac S, Rakočević ZL. Surface modification of polyethylene by Ag+ and Au+ ion implantation observed by phase imaging atomic force microscopy. in Surface and Coatings Technology. 2012;206(19-20):4242-4248. doi:10.1016/j.surfcoat.2012.04.032 .
Nenadović, Miloš, Potočnik, Jelena, Ristic, M., Štrbac, Svetlana, Rakočević, Zlatko Lj., "Surface modification of polyethylene by Ag+ and Au+ ion implantation observed by phase imaging atomic force microscopy" in Surface and Coatings Technology, 206, no. 19-20 (2012):4242-4248, https://doi.org/10.1016/j.surfcoat.2012.04.032 . .