Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments
Само за регистроване кориснике
2004
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
A procedure for dynamic calibration of a sensor gas calorimeter, resulting with a calibration transfer function, instead with a calibration line, is presented. The main factors influencing the calibration transfer function have been assessed. The calibration transfer function enables measurement of the heat generation rates during adsorption, necessary for obtaining a complete picture about adsorption kinetics.
Кључне речи:
calorimeter / sensor gas / dynamic calibration / transfer functionИзвор:
Thermochimica Acta, 2004, 415, 1-2, 21-25Издавач:
- Elsevier, Amsterdam
DOI: 10.1016/j.tca.2003.08.027
ISSN: 0040-6031
WoS: 000221733300005
Scopus: 2-s2.0-2342544040
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Petkovska, Menka AU - Antov, D AU - Zimmermann, W AU - Schein, E PY - 2004 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/698 AB - A procedure for dynamic calibration of a sensor gas calorimeter, resulting with a calibration transfer function, instead with a calibration line, is presented. The main factors influencing the calibration transfer function have been assessed. The calibration transfer function enables measurement of the heat generation rates during adsorption, necessary for obtaining a complete picture about adsorption kinetics. PB - Elsevier, Amsterdam T2 - Thermochimica Acta T1 - Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments EP - 25 IS - 1-2 SP - 21 VL - 415 DO - 10.1016/j.tca.2003.08.027 ER -
@article{ author = "Petkovska, Menka and Antov, D and Zimmermann, W and Schein, E", year = "2004", abstract = "A procedure for dynamic calibration of a sensor gas calorimeter, resulting with a calibration transfer function, instead with a calibration line, is presented. The main factors influencing the calibration transfer function have been assessed. The calibration transfer function enables measurement of the heat generation rates during adsorption, necessary for obtaining a complete picture about adsorption kinetics.", publisher = "Elsevier, Amsterdam", journal = "Thermochimica Acta", title = "Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments", pages = "25-21", number = "1-2", volume = "415", doi = "10.1016/j.tca.2003.08.027" }
Petkovska, M., Antov, D., Zimmermann, W.,& Schein, E.. (2004). Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments. in Thermochimica Acta Elsevier, Amsterdam., 415(1-2), 21-25. https://doi.org/10.1016/j.tca.2003.08.027
Petkovska M, Antov D, Zimmermann W, Schein E. Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments. in Thermochimica Acta. 2004;415(1-2):21-25. doi:10.1016/j.tca.2003.08.027 .
Petkovska, Menka, Antov, D, Zimmermann, W, Schein, E, "Dynamic calibration of a sensor gas calorimeter for measurement of heat generation rates during kinetic of adsorption experiments" in Thermochimica Acta, 415, no. 1-2 (2004):21-25, https://doi.org/10.1016/j.tca.2003.08.027 . .