Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns
Само за регистроване кориснике
2000
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
Gas chromatographic retention indices (1) for series of 20 synthesized N-methyl-N-substituted benzamides on DB-I, DB-5 and DB-WAX capillary columns isothermal at 170, 190 and 210 degreesC, and using temperature programmed gas chromatography (TPGC) have been determined within standard deviation of 0.6 i.u. The isothermal data obtained on these columns and TPGC data are compared and a comparison of the retention indices, DeltaI and dI/dT values presented as linear regression equations with correlation coefficient greater than 0.9970 within standard deviation of 0.6 i.u. The best resolution of the structural isomers is obtained using DB-1 capillary column.
Извор:
Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry, 2000, 39, 9, 694-699Издавач:
- Natl Inst Science Communication, New Delhi
Институција/група
Tehnološko-metalurški fakultetTY - JOUR AU - Antonović, Dušan AU - Mijin, Dušan AU - Petrović, Slobodan AU - Stojanović, ND AU - Nikolić, AD PY - 2000 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/279 AB - Gas chromatographic retention indices (1) for series of 20 synthesized N-methyl-N-substituted benzamides on DB-I, DB-5 and DB-WAX capillary columns isothermal at 170, 190 and 210 degreesC, and using temperature programmed gas chromatography (TPGC) have been determined within standard deviation of 0.6 i.u. The isothermal data obtained on these columns and TPGC data are compared and a comparison of the retention indices, DeltaI and dI/dT values presented as linear regression equations with correlation coefficient greater than 0.9970 within standard deviation of 0.6 i.u. The best resolution of the structural isomers is obtained using DB-1 capillary column. PB - Natl Inst Science Communication, New Delhi T2 - Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry T1 - Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns EP - 699 IS - 9 SP - 694 VL - 39 UR - https://hdl.handle.net/21.15107/rcub_technorep_279 ER -
@article{ author = "Antonović, Dušan and Mijin, Dušan and Petrović, Slobodan and Stojanović, ND and Nikolić, AD", year = "2000", abstract = "Gas chromatographic retention indices (1) for series of 20 synthesized N-methyl-N-substituted benzamides on DB-I, DB-5 and DB-WAX capillary columns isothermal at 170, 190 and 210 degreesC, and using temperature programmed gas chromatography (TPGC) have been determined within standard deviation of 0.6 i.u. The isothermal data obtained on these columns and TPGC data are compared and a comparison of the retention indices, DeltaI and dI/dT values presented as linear regression equations with correlation coefficient greater than 0.9970 within standard deviation of 0.6 i.u. The best resolution of the structural isomers is obtained using DB-1 capillary column.", publisher = "Natl Inst Science Communication, New Delhi", journal = "Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry", title = "Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns", pages = "699-694", number = "9", volume = "39", url = "https://hdl.handle.net/21.15107/rcub_technorep_279" }
Antonović, D., Mijin, D., Petrović, S., Stojanović, N.,& Nikolić, A.. (2000). Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns. in Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry Natl Inst Science Communication, New Delhi., 39(9), 694-699. https://hdl.handle.net/21.15107/rcub_technorep_279
Antonović D, Mijin D, Petrović S, Stojanović N, Nikolić A. Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns. in Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry. 2000;39(9):694-699. https://hdl.handle.net/21.15107/rcub_technorep_279 .
Antonović, Dušan, Mijin, Dušan, Petrović, Slobodan, Stojanović, ND, Nikolić, AD, "Gas chromatographic retention indices for the N-methyl-N-substituted benzamides on capillary columns" in Indian Journal of Chemistry - Section B Organic and Medicinal Chemistry, 39, no. 9 (2000):694-699, https://hdl.handle.net/21.15107/rcub_technorep_279 .