Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation
Apstrakt
Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.
Izvor:
Acta Physica Polonica A, 2012, 122, 4, 655-658Finansiranje / projekti:
- Fizički i funkcionalni efekti interakcije zračenja sa elektrotehničkim i biološkim sistemima (RS-MESTD-Basic Research (BR or ON)-171007)
- Nove tehnologije za monitoring i zaštitu životnog okruženja od štetnih hemijskih supstanci i radijacionog opterećenja (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-43009)
- Istraživanje mogućnosti primene otpadnih i recikliranih materijala u betonskim kompozitima, sa ocenom uticaja na životnu sredinu, u cilju promocije održivog građevinarstva u srbiji (RS-MESTD-Technological Development (TD or TR)-36017)
DOI: 10.12693/APhysPolA.122.655
ISSN: 0587-4246
WoS: 000309796900003
Scopus: 2-s2.0-84867155225
Institucija/grupa
Tehnološko-metalurški fakultetTY - JOUR AU - Stanković, Srboljub J. AU - Ilic, R. D. AU - Živanović, Miloš Z. AU - Janković, Ksenija S. AU - Lončar, Boris B. PY - 2012 UR - http://TechnoRep.tmf.bg.ac.rs/handle/123456789/5714 AB - Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials. T2 - Acta Physica Polonica A T1 - Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation EP - 658 IS - 4 SP - 655 VL - 122 DO - 10.12693/APhysPolA.122.655 ER -
@article{ author = "Stanković, Srboljub J. and Ilic, R. D. and Živanović, Miloš Z. and Janković, Ksenija S. and Lončar, Boris B.", year = "2012", abstract = "Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick SiO2 layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.", journal = "Acta Physica Polonica A", title = "Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation", pages = "658-655", number = "4", volume = "122", doi = "10.12693/APhysPolA.122.655" }
Stanković, S. J., Ilic, R. D., Živanović, M. Z., Janković, K. S.,& Lončar, B. B.. (2012). Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation. in Acta Physica Polonica A, 122(4), 655-658. https://doi.org/10.12693/APhysPolA.122.655
Stanković SJ, Ilic RD, Živanović MZ, Janković KS, Lončar BB. Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation. in Acta Physica Polonica A. 2012;122(4):655-658. doi:10.12693/APhysPolA.122.655 .
Stanković, Srboljub J., Ilic, R. D., Živanović, Miloš Z., Janković, Ksenija S., Lončar, Boris B., "Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation" in Acta Physica Polonica A, 122, no. 4 (2012):655-658, https://doi.org/10.12693/APhysPolA.122.655 . .