Претраживање
Приказ резултата 21-30 од 42
Corrosion behavior of duplex polyaniline/epoxy coating on mild steel in 3% NaCl / Koroziono ponašanje dvoslojne polianilin/epoksidne prevlake na mekom čeliku u 3% rastvoru NaCl
(Association of Chemical Engineers of Serbia, 2005)
The corrosion behavior and thermal stability of epoxy coatings electrodeposited on mild steel and on mild steel with electrochemically deposited polyaniline (PANI) film were investigated by electrochemical impedance ...
Synthesis and electrochemical properties of polypyrrole, polyaniline and poly-3-methyl thiophene / Sinteza i elektrohemijska svojstva polipirola, polianilina i poli-3-metiltiofena
(Association of Chemical Engineers of Serbia, 2000)
In this article, the results of a study of the electrochemical polymerization of pyrrole and the chemical polymerization of pyrrole, aniline and 3-methyl thiophene initiated by FeCh are presented. The electrochemical ...
Characterization of oxide coatings formed by plasma electrolytic oxidation of aluminum in sodium tungstate / Karakterizacija oksidnih slojeva dobijenih plazma elektrolitičkom oksidacijom aluminijuma u natrijum volframatu
(Engineering Society for Corrosion, Belgrade, Serbia, 2013)
This paper presents our recent research on morphology and phase composition of oxide coatings formed by plasma electrolytic oxidation of aluminum in 0.1 M sodium tungstate at constant current density of 15 mA/cm2 and ...
Corrosion properties of an aluminium alloy 7000 series after a new two step precipitation hardening / Otpornost prema koroziji aluminijumske legure serije 7000 posle novog dvostepenog termičkog taloženja
(Engineering Society for Corrosion, Belgrade, Serbia, 2014)
Corrosion properties of an aluminium alloy 7000 series were investigated by different electrochemical methods. The alloy was subjected to the one-step and to a new two-step precipitation hardening. Polarization measurements ...
The influence of thin benzoate-doped polyaniline coatings on corrosion protection of mild steel in different environments
(Tatranské Matliare : Slovak Society of Chemical Engineering, 2013)
The corrosion process of mild steel in the presence of benzoate-doped polyaniline coatings exposed to 3% NaCl has been investigated. This system was also tested for cathodic protection and it has proven more efficient ...
Laser cleaning of textile artifacts with metal threads: Process parameter optimization / Lasersko čišćenje tekstilnih eksponata sa korodiranim metalnim nitima - optimzacije parametara procesa
(Military Technical Institute, Belgrade, 2014)
This paper presents the results of the laser cleaning effects on textile samples with corroded metallic threads. In many museum collections, there are textile exhibits like uniforms, national costumes, flags and home ...
Oxidation and erosion behaviour of SiC-HfC multilayered composite
(Univerzitet u Novom Sadu - Tehnološki fakultet, Novi Sad, 2014)
The fabrication of SiC-HfC ceramic composite via self-propagating high-temperature synthesis and simultaneous consolidation was investigated. Dense composite consisting of alternating layers of SiC and HfC was obtained by ...
Modified tannins for alkyd based anticorrosive coatings / Primena modifikovanih tanina u antikorozionim alkidnim premazima
(Engineering Society for Corrosion, Belgrade, Serbia, 2019)
The study of the synthesis of anticorrosive inhibitors, based on chemically modified tannins, and their use in alkyd based coatings to improve anticorrosive properties is presented in this work. Two methods of tannin ...
Savremeni čelici - dvojnikovanjem izazvana plastičnost
(DUZS - Društvo za unapređivanje zavarivanja u Srbiji, Beograd, 2014)
A significant increase in the research activity dedicated to high manganese TWIP steels has occurred during the past few years, motivated by the breakthrough combination of strength and ductility possessed by these alloys. ...
Economizer water-wall damages initiated by feedwater impurities
(Savez hemijskih inženjera, Beograd, 2014)
The main causes of efficiency loss in thermal power plants are boiler tube failures that diminish unit reliability and availability, and raise the cost of the electric energy. For that reason, the regular examination of ...