Приказ основних података о документу
In vitro cytotoxicity assessment of intelligent acrylate based hydrogels with incorporated copper in wound management
dc.creator | Vuković, Jovana | |
dc.creator | Babić, Marija | |
dc.creator | Antić, Katarina | |
dc.creator | Filipović, Jovanka M. | |
dc.creator | Stojanović, Sanja T. | |
dc.creator | Najman, Stevo | |
dc.creator | Tomić, Simonida | |
dc.date.accessioned | 2021-03-10T13:08:38Z | |
dc.date.available | 2021-03-10T13:08:38Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 0254-0584 | |
dc.identifier.uri | http://TechnoRep.tmf.bg.ac.rs/handle/123456789/3352 | |
dc.description.abstract | In order to evaluate biological response and potential toxicity prior to clinical use as wound dressing materials, three series of hydrogels, based on 2-hydroxyethyl acrylate (HEA) and itaconic acid (IA), unloaded, with incorporated copper(II) ions and reduced copper, were subjected to cytotoxicity testing on L929 cell line (mouse fibroblasts). MTT test revealed proper fibroblast growth in the presence of tested hydrogels, with an absence of any acute toxic effects. Mechanical properties of all three hydrogel series were studied by dynamic mechanical analysis (DMA) and obtained results indicated dominant elastic over viscous behaviour, which supports their application in wound management. The temperature sensitive behaviour of the hydrogels was detected in swelling study conducted in wide range of temperature values 25-50 degrees C, in buffer pH 7.40. The hydrogels exhibited excellent microbial barrier characteristics against Pseudomonas aeruginosa, reducing the risk of bacterial infection in wound bed. | en |
dc.publisher | Elsevier Science Sa, Lausanne | |
dc.relation | info:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172062/RS// | |
dc.relation | info:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172026/RS// | |
dc.rights | restrictedAccess | |
dc.source | Materials Chemistry and Physics | |
dc.subject | Polymers | en |
dc.subject | Mechanical properties | en |
dc.subject | Transport properties | en |
dc.subject | Biomaterials | en |
dc.title | In vitro cytotoxicity assessment of intelligent acrylate based hydrogels with incorporated copper in wound management | en |
dc.type | article | |
dc.rights.license | ARR | |
dc.citation.epage | 163 | |
dc.citation.other | 175: 158-163 | |
dc.citation.rank | M22 | |
dc.citation.spage | 158 | |
dc.citation.volume | 175 | |
dc.identifier.doi | 10.1016/j.matchemphys.2016.03.009 | |
dc.identifier.scopus | 2-s2.0-84977934865 | |
dc.identifier.wos | 000374612000020 | |
dc.type.version | publishedVersion |